17 17  = 1. Introduction =
18 18  
19 19  == 1.1 What is HP0C ==
20 20  
21 21  (((
22 -The HP0C is a light hotspot for Helium. User can connect their sensors to Helium network via HP0C.
21 +The HP0C is an open-source LoRaWAN Gateway. It lets you bridge LoRa wireless network to an IP network via WiFi, Ethernet. The LoRa wireless allows users to send data and reach extremely long ranges at low data-rates.
22 +
23 +
24 +HP0C has pre-configured standard LoRaWAN frequency bands to use for different countries. Users can also customize the frequency bands to use in their own LoRaWAN network.
25 +
26 +
27 +== 1.2 Specifications ==
28 +
29 +**Hardware System:**
30 +
31 + Linux Part:
32 +
33 +* Dragino H3-Core Linux Module
34 +
35 +* Quad-core Cortex-A7 1.2Ghz
36 +
37 +* RAM: 512MB
38 +
39 +* eMMC: 4GB
40 +
41 +**Interface:**
42 +
43 +* 10M/100M RJ45 Ports x 1
44 +* LoRaWAN Wireless
45 +
46 +**Operating Condition:**
47 +
48 +* Work Temperature: -20 ~~ 65°C
49 +* Storage Temperature: -20 ~~ 65°C
50 +* Power Input: 5V 2A, DC
51 +
52 +=== 1.3 Features ===
53 +
54 +* Open Source Debian system
55 +* Managed by Web GUI, SSH via WAN or WiFi
56 +* Remote access with Reverse-SSH
57 +* Emulates 49x LoRa demodulators
58 +* LoRaWAN Gateway
59 +* 10 programmable parallel demodulation paths
60 +* Pre-configure to support different LoRaWAN regional settings.
61 +* Allow to customize LoRaWAN regional parameters.
62 +* Support Local decode ABP end node info and transfer to MQTT server
63 +* Support different level log in.
64 +
65 +World Widely. Include US and EU
66 +
67 +== 1.4 Block Diagram ==
68 +
69 +
70 +[[image:1652877681673-109.png]]
71 +
72 +
73 += 2. SSH Access for Linux console =
74 +
75 +Connect the HP0C Ethernet port to your router and HP0C will obtain an IP address from your router. In the router’s management portal, you should be able to find what IP address the router has assigned to the HP0C. You can use this IP to connect the SSH access of HP0C.
76 +
77 +(((
78 +IP address:  IP address of HP0C
23 23  )))
80 +
81 +(((
82 +Port:         22
83 +)))
84 +
85 +(((
86 +User Name:      (% style="color:green" %)**root**
87 +)))
88 +
89 +(((
90 +Password:  (% style="color:green" %)**dragino** (default)
91 +)))
92 +
93 +(((
94 +After logging in, you will be in the Linux console and can enter commands as shown below.
95 +)))
96 +
97 +[[image:1652878416905-627.png||height="263" width="685"]]
98 +
99 += 9. Supports =
100 +
101 +If you are experiencing issues and can’t solve, you can send mail to [[support@dragino.com>>mailto:support@dragino.com]].
102 +
103 +With your question as detail as possible. We will reply and help you in the shortest.
104 +
105 +
106 += 10. Order Info =
107 +
108 +**HP0C-XXX**
109 +
110 +**XXX**: Frequency Band
111 +
112 +* **AS923**: LoRaWAN AS923 band
113 +* **AU915**: LoRaWAN AU915 band
114 +* **EU868**: LoRaWAN EU868 band
115 +* **KR920**: LoRaWAN KR920 band
116 +* **US915**: LoRaWAN US915 band
117 +* **IN865**: LoRaWAN IN865 band
118 +
119 += 11. Manufacturer Info =
120 +
121 +**Shenzhen Dragino Technology Development co. LTD**
122 +
123 +Room 202, Block B, BCT Incubation Bases (BaoChengTai),  No.8 CaiYunRoad
124 +
125 +LongCheng Street, LongGang District ; Shenzhen 518116,China
126 +
127 +[[image:file:///C:/Users/11315/AppData/Local/Temp/msohtmlclip1/01/clip_image002.png]]
128 +
129 += 12. FCC Warning =
130 +
131 +This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
132 +
133 +~-~- Reorient or relocate the receiving antenna.
134 +
135 +~-~- Increase the separation between the equipment and receiver.
136 +
137 +~-~- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
138 +
139 +~-~- Consult the dealer or an experienced radio/TV technician for help.
140 +
141 +
142 +Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
143 +
144 +
145 +The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.
146 +)))