<
From version < 77.1 >
edited by Kilight Cao
on 2023/11/01 17:02
To version < 61.1 >
edited by Kilight Cao
on 2022/08/31 11:46
>
Change comment: Uploaded new attachment "image-20220831114647-9.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -11,196 +11,199 @@
11 11  
12 12  (((
13 13  (((
14 -The Dragino LoRaWAN gateway can communicate with [[LORIOT>>url:https://www.loriot.io/]] LoRaWAN Network Server:
14 +The Dragino LoRaWAN gateway can commuicate with [[LORIOT>>url:https://www.loriot.io/]] LoRaWAN Network Server:
15 15  )))
16 16  )))
17 17  
18 18  (((
19 19  (((
20 -Below list the products and requirements that support communication with LORIOT using Semtech UDP:
20 +Below list the support products and Requirements:
21 21  )))
22 22  )))
23 23  
24 +1. (((
24 24  (((
26 +LoRaWAN Gateway model: [[LPS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/148-lps8.html]], [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]], [[DLOS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/160-dlos8.html]]
27 +)))
28 +)))
29 +1. (((
25 25  (((
26 - ~1. LoRaWAN Gateway model: [[LPS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/148-lps8.html]], [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]], [[DLOS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/160-dlos8.html]],[[LPS8N>>https://www.dragino.com/products/lora-lorawan-gateway/item/228-lps8v2.html]],[[LG308N>>https://www.dragino.com/products/lora-lorawan-gateway/item/229-lg308n.html]]
31 +Firmware version sinc:[[LG02_LG08~~-~~-build-v5.4.1590459021-20200526-1012>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LPS8/Firmware/Release/]]
27 27  
28 -(((
29 -(((
30 - 2. Firmware version since : [[lgw~~-~~-build-v5.4.1661158991-20220822-1704>>https://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LPS8/Firmware/Release/]]
31 31  
32 32  
33 33  )))
34 34  )))
35 -)))
36 -)))
37 37  
38 -= 2. Gateway Registration for Semtech UDP =
38 += 2. Gateway Setup Instruction =
39 39  
40 40  == 2.1 Step 1: Get Gateway ETH0 MAC Address ==
41 41  
42 42  
43 -Dragino LoRaWAN gateway uses ETH0 MAC address to generate Gateway EUI to communicate with LORIOT, The user needs to find the ETH0 MAC in the "(% style="color:blue" %)**System -> System Overview**" (%%)menu.
43 +(((
44 +Dragino LoRaWAn gateway use ETH0 MAC address to generate Gateway ID to communicate with LORIOT, User can get the ETH0 MAC address from SSH access and run **ifconfig** command.
44 44  
46 +
47 +)))
45 45  
46 -[[image:image-20220831110558-1.png||height="595" width="909"]]
49 +[[image:image-20220524175559-2.png]]
47 47  
51 +Get ETH0 MAC address
48 48  
49 -== 2.2 Step 2: Register Gateway ==
50 50  
54 +(((
55 +(% style="color:red" %)**Note**: **To make set up more friendly, the ETH0 will show on the LORIOT page in a new firmware version.**
51 51  
52 -[[image:image-20220831111032-2.png||height="617" width="1263"]]
53 53  
58 +
59 +)))
54 54  
55 -(% style="color:blue" %)**Choose gateway model**
61 +== 2.2 Step 2: Choose LORIOT service ==
56 56  
57 -[[image:image-20220831111132-3.png||height="596" width="1223"]]
58 58  
64 +[[image:image-20220531182035-1.png]]
59 59  
60 -(% style="color:red" %)**Special reminder: **(%%)If the user does not find the gateway Model, then (% style="color:blue" %)**git ~-~-> Packet Forwarder Semtech**(%%)  can be selected
66 +Choose to use LORIOT as LoRaWAN service provider
61 61  
62 -[[image:image-20220831115222-11.png||height="596" width="1221"]]
63 63  
64 64  
65 -(% style="color:blue" %)**Enter the ETH0 MAC of the gateway**
70 +[[image:image-20220531182109-2.png]]
66 66  
67 -[[image:image-20220831111307-4.png||height="850" width="1237"]]
72 +Install and choose the LORIOT server to be used
68 68  
69 69  
70 -[[image:image-20220831111821-5.png||height="604" width="1239"]]
71 71  
76 +== 2.3 Step 3: Checking Connection Status ==
72 72  
73 -== 2.3 Step 3: Back to Semtech UDP page ==
74 74  
79 +[[image:image-20220531182202-3.png]]
75 75  
76 -Back to the page of Semtech UDP check the secondary server settings and click the button of (% style="color:blue" %)**Save&Apply.**
81 +Click to Home page and check the connection status
77 77  
78 -(% class="box infomessage" %)
79 -(((
80 -Server Address:  ~-~-> LORIOT Different servers use different addresses, Such as: **next.loriot.io**
81 81  
82 -Uplink /Downlink Port :  ~-~-> 1780
83 -)))
84 84  
85 -[[image:image-20220831112553-7.png]]
85 +== 2.4 Step 4: Setup Account in LORIOT ==
86 86  
87 87  
88 -== 2.4 Step 4: Check Connection ==
88 +Login [[LORIOT>>url:https://www.loriot.io/]] and create account
89 89  
90 +[[image:image-20220531182253-4.png]]
90 90  
91 -(((
92 -LORIOT will show disconnect if Gateway doesn't connect
93 -)))
92 +Log in LORIOT portal
94 94  
95 -(((
96 -LORIOT will show connect if Gateway connect to LORIOT ok.
97 -)))
98 98  
99 -[[image:image-20220831114125-8.png||height="561" width="1150"]]
100 100  
96 +Choose to use the server same as the gateway setting
101 101  
102 -== 2.5  Trouble Shooting ==
98 +[[image:image-20220526111312-1.png||height="493" width="1098"]]
103 103  
100 +Choose server
104 104  
105 -User can check the station log in the(% style="color:blue" %)** LogRead ~-~-> System Log **(%%)page.
106 106  
107 -[[image:image-20220831114647-9.png||height="706" width="894"]]
108 108  
104 +Create a New Network
109 109  
110 -and recode the station log in the (% style="color:blue" %)** LogRead  ~-~->  Recode Log**(%%) page.
106 +[[image:image-20220526111425-2.png||height="579" width="1378"]]
111 111  
112 -[[image:image-20220831114746-10.png||height="292" width="972"]]
108 +Create a New Network
113 113  
114 114  
111 +[[image:image-20220526111500-3.png]]
115 115  
116 -= 3. Gateway Registration for Basics Station =
113 +Create a New Network
117 117  
118 118  
119 -The LoRa Basics™ Station protocol simplifies the management of large-scale LoRaWAN networks. LoRa Basics™ Station is the preferred way of connecting Gateways to LORIOT. [[The LoRa Basics Station doc>>url:https://www.thethingsindustries.com/docs/gateways/lora-basics-station/]]
120 120  
121 -(((
122 -(% style="color:blue" %)**Below list the support products and Requirements:**
123 -)))
117 +== 2.5 Step 5: Register the gateway ==
124 124  
125 -1. LoRaWAN Gateway model:  [[LIG16>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/171-lig16.html]], [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]], [[DLOS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/160-dlos8.html]] ,[[LPS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/148-lps8.html]]
126 126  
127 - 2.  Firmware version since :       
120 +[[image:image-20220526111650-4.png]]
128 128  
122 +Register the Gateway in LORIOT
129 129  
130 -(% style="color:blue" %)**What do you need to prepare?**
131 131  
132 -A gateway that can access the internet normally
133 133  
126 +Choose LG308 as gateway model
134 134  
135 -== 3.1 Step 1: Register Gateway ==
128 +[[image:image-20220526111742-5.png||height="496" width="1372"]]
136 136  
137 -[[image:image-20231101162122-1.png||height="528" width="1022"]]
130 +Choose LG308 as gateway model
138 138  
139 139  
140 -Enter the gateway ID into the Custom EUI
141 141  
142 -[[image:image-20231101162623-2.png||height="526" width="1024"]]
134 +Input Gateway ETH0 address
143 143  
136 +[[image:image-20220526111918-6.png||height="744" width="1336"]]
144 144  
145 -== 3.2  Step 2: Generate and Download TLS Certificate ==
138 +Choose SX1301 Reference and use SPI protocol
146 146  
147 -[[image:image-20231101163647-3.png||height="529" width="1024"]]
148 148  
149 149  
150 -Download LORIOT's three TLS certificates, which are:
142 +Choose the right Frequency Band and input location
151 151  
152 -(% style="color:red" %)**DigiCert_Global_Root_G2.crt , "Gateway EUI".gws.loriot.io.crt , "Gateway EUI".gws.loriot.io.key**
144 +[[image:image-20220526112029-7.png||height="620" width="1306"]]
153 153  
154 -[[image:image-20231101163743-4.png||height="528" width="1024"]]
146 +Set up regional settings.
155 155  
156 156  
157 157  
158 -== 3. Step 3: Access the gateway GUI ==
150 +== 2.6 Step 6: Check Connection ==
159 159  
160 -User need to upload the TLS certificate and configure the LNS URI
161 161  
153 +(((
154 +LORIOT will show disconnect if Gateway doesn't connect
155 +)))
162 162  
163 -== 3.4  Step 4: Configure Station ==
157 +(((
158 +LORIOT will show connect if Gateway connect to LORIOT ok.
164 164  
165 -User need to input Server URI, Server CUPS Key and LNS Key, as well as install CUPS certificate.
160 +
161 +)))
166 166  
167 -(% style="color:blue" %)**just to clarify:**
163 +[[image:image-20220526112143-8.png||height="654" width="1373"]]
168 168  
169 - Server URI  ~-~->  Server Address, Example: wss:~/~/ap2.loriot.io:717
170 - TLS CA Certificate         ~-~-> 
171 - TLS Key  ~-~-> 
172 - TLS Certificate  ~-~->   
165 +Status: Connected
173 173  
174 174  
175 -== 3.5  Start Station ==
176 176  
177 -When the user has finished the configuration, Please click "Save&Apply" to start station to connect LORIOT.
169 +== 2.7 Debug If there is connection issue ==
178 178  
179 179  
180 -== 3.6  Check Connection ==
172 +User can check if loriot is running by checking the web ui
181 181  
182 -If user completes the above steps,which will see Log in the LORIOT.
183 183  
184 -[[image:image-20231101165306-5.png||height="542" width="1050"]]
175 +[[image:image-20220526112917-18.png]]
185 185  
177 +Status: Connected
186 186  
187 -== 3.7  Trouble Shooting ==
188 188  
189 -User can check the station log in the** LogRead ~-~-> System Log **page.
180 +(((
181 +If user want to see more log, he can run below commands in Linux and see the full log:
182 +)))
190 190  
191 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/Notes%20for%20TTN/WebHome/image-20220526135845-15.png?rev=1.1||alt="image-20220526135845-15.png"]]
184 +(% class="box" %)
185 +(((
186 +(((
187 +ps | grep "loriot_dragino" | grep -v grep | awk '{print $1}' | xargs kill -s 9
188 +/usr/bin/loriot_dragino_lg308_spi -f -s eu1.loriot.io
189 +)))
190 +)))
192 192  
192 +(((
193 +
193 193  
194 -and recode the station log in the** LogRead  ~-~->  Recode Log** page.
195 +Above two commands will first kill the loriot process and run it again to get more output.
196 +)))
195 195  
196 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/Notes%20for%20TTN/WebHome/image-20220526135940-16.png?rev=1.1||alt="image-20220526135940-16.png"]]
198 +[[image:image-20220530145011-1.png]]
197 197  
200 +Get more debug info
198 198  
199 199  
200 200  
201 -= 4. End Device Note =
204 += 3. End Device Note =
202 202  
203 -== 4.1 Downlink Setup ==
206 +== 3.1 Downlink Setup ==
204 204  
205 205  
206 206  [[image:image-20220530145133-2.png]]
image-20220831114746-10.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Kilight
Size
... ... @@ -1,1 +1,0 @@
1 -34.2 KB
Content
image-20220831115222-11.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Kilight
Size
... ... @@ -1,1 +1,0 @@
1 -133.7 KB
Content
image-20231101162122-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Kilight
Size
... ... @@ -1,1 +1,0 @@
1 -377.7 KB
Content
image-20231101162623-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Kilight
Size
... ... @@ -1,1 +1,0 @@
1 -242.0 KB
Content
image-20231101163647-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Kilight
Size
... ... @@ -1,1 +1,0 @@
1 -124.7 KB
Content
image-20231101163743-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Kilight
Size
... ... @@ -1,1 +1,0 @@
1 -167.6 KB
Content
image-20231101165306-5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Kilight
Size
... ... @@ -1,1 +1,0 @@
1 -219.7 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0