From version < 9.5 >
edited by Xiaoling
on 2022/09/17 17:21
To version < 9.3 >
edited by Xiaoling
on 2022/07/22 13:48
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -10,7 +10,7 @@
10 10  (((
11 11  
12 12  
13 -Single Channels gateway are mainly used for private LoRa protocol. Not recommend for LoRaWAN protocol. Below models has such limitation:
13 +Single Channels gateway are mainly used for private LoRa protocol. Not recommend for LoRaWAN protocol.Below models has such limitation:
14 14  )))
15 15  
16 16  * (((
... ... @@ -42,12 +42,11 @@
42 42  
43 43  )))
44 44  
45 -== 2.1 Step 1: Creat ABP device in LoRaWAN Server ==
45 +== 2.1 Step1: Creat ABP device in LoRaWAN Server ==
46 46  
47 47  
48 48  Log in TTN, Create an ABP device in the application and input the network session key (NETSKEY), app session key (APPSKEY) from the device.
49 49  
50 -
51 51  [[image:image-20220527164521-1.png]]
52 52  
53 53  Create ABP device
... ... @@ -60,17 +60,17 @@
60 60  
61 61  )))
62 62  
63 -== 2.2 Step 2: Configure End Node radio parameters ==
62 +== 2.2 Step2: Configure End Node radio parameters ==
64 64  
65 65  
66 66  Run AT Command to make LoRaWAN End Node to work in Single frequency & ABP mode. Below is the AT commands:
67 67  
68 68  * AT+FDR Reset Parameters to Factory Default, Keys Reserve
69 -* AT+NJM=0 Set to ABP mode  ~-~->  This must be 0
70 -* AT+ADR=0 Set the Adaptive Data Rate Off  ~-~->  This must be 0
71 -* AT+DR=5  Set Data Rate (Set AT+DR=3 for 915 band)  ~-~->  Can use other DR but need to match the gateway setting.
72 -* AT+CHS=868400000  Set transmit frequency to 868.4Mhz  ~-~->  Can use other Frequency but need to match the gateway setting.
73 -* AT+DADDR=26 01 1A F1  Set Device Address to 26 01 1A F1  ~-~->  Make sure this match Server setting
68 +* AT+NJM=0 Set to ABP mode ~-~-> This must be 0
69 +* AT+ADR=0 Set the Adaptive Data Rate Off ~-~-> This must be 0
70 +* AT+DR=5  Set Data Rate (Set AT+DR=3 for 915 band)  ~-~-> Can use other DR but need to match the gateway setting.
71 +* AT+CHS=868400000  Set transmit frequency to 868.4Mhz  ~-~-> Can use other Frequency but need to match the gateway setting.
72 +* AT+DADDR=26 01 1A F1  Set Device Address to 26 01 1A F1 ~-~-> Make sure this match Server setting
74 74  * ATZ Reset MCU
75 75  
76 76  
... ... @@ -77,20 +77,18 @@
77 77  
78 78  As shown in below:
79 79  
80 -
81 81  [[image:image-20220601111608-1.png]]
82 82  
83 83  Configure Device
84 84  
85 85  
84 +== 2.3 Step3: Configure Gateway ==
86 86  
87 -== 2.3 Step 3: Configure Gateway ==
88 88  
89 -
90 90  Configure gateway so it can receive the packet sent from End Node:
91 91  
92 -* RX frequency: 868400000  ~-~->  Must same as the End Node AT+CHS settings.
93 -* SF: 7  ~-~->  Must match the End Node DR settings. More about this please check [[LoRaWAN Region setting>>url:https://lora-alliance.org/sites/default/files/2018-07/lorawan_regional_parameters_v1.0.3reva_0.pdf]]. The End Node us EU868 frequency band, the DR5 equal to SF7/ Bandwidth 125Khz, so we need to set SF=7 here (ABove document Page 16).
89 +* RX frequency: 868400000 ~-~-> Must same as the End Node AT+CHS settings.
90 +* SF: 7 ~-~-> Must match the End Node DR settings. More about this please check [[LoRaWAN Region setting>>url:https://lora-alliance.org/sites/default/files/2018-07/lorawan_regional_parameters_v1.0.3reva_0.pdf]]. The End Node us EU868 frequency band, the DR5 equal to SF7/ Bandwidth 125Khz, so we need to set SF=7 here (ABove document Page 16).
94 94  
95 95  
96 96  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0