... ... @@ -8,8 +8,6 @@
8 8  = 1. Limitation for LG01. LG02, OLG01, OLG01-N, OLG02 =
9 9  
10 10  (((
11 -
12 -
13 13  Single Channels gateway are mainly used for private LoRa protocol. Not recommend for LoRaWAN protocol.Below models has such limitation:
14 14  )))
15 15  
... ... @@ -33,7 +33,6 @@
33 33  
34 34  = 2. Set Up Dragino End Node to work for Single Channel Gateway such as LG01/LG02 =
35 35  
36 -
37 37  To work with single channel gateway, users need to set Dragino End Device to work in (% style="color:#037691" %)**ABP mode**(%%) and (% style="color:#037691" %)**transmit in only one frequency**.
38 38  
39 39  (((
... ... @@ -44,7 +44,6 @@
44 44  
45 45  == 2.1 Step1: Creat ABP device in LoRaWAN Server ==
46 46  
47 -
48 48  Log in TTN, Create an ABP device in the application and input the network session key (NETSKEY), app session key (APPSKEY) from the device.
49 49  
50 50  [[image:image-20220527164521-1.png]]
... ... @@ -60,7 +60,6 @@
60 60  
61 61  == 2.2 Step2: Configure End Node radio parameters ==
62 62  
63 -
64 64  Run AT Command to make LoRaWAN End Node to work in Single frequency & ABP mode. Below is the AT commands:
65 65  
66 66  * AT+FDR Reset Parameters to Factory Default, Keys Reserve
... ... @@ -71,27 +71,23 @@
71 71  * AT+DADDR=26 01 1A F1 Set Device Address to 26 01 1A F1 ~-~-> Make sure this match Server setting
72 72  * ATZ Reset MCU
73 73  
74 -
75 75  As shown in below:
76 76  
77 -[[image:image-20220601111608-1.png]]
71 +[[image:image-20220527164615-2.png]]
78 78  
79 79  Configure Device
80 80  
81 -
82 82  == 2.3 Step3: Configure Gateway ==
83 83  
84 -
85 85  Configure gateway so it can receive the packet sent from End Node:
86 86  
87 87  * RX frequency: 868400000 ~-~-> Must same as the End Node AT+CHS settings.
88 88  * SF: 7 ~-~-> Must match the End Node DR settings. More about this please check [[LoRaWAN Region setting>>url:https://lora-alliance.org/sites/default/files/2018-07/lorawan_regional_parameters_v1.0.3reva_0.pdf]]. The End Node us EU868 frequency band, the DR5 equal to SF7/ Bandwidth 125Khz, so we need to set SF=7 here (ABove document Page 16).
89 89  
90 -[[image:image-20220527164647-3.png]]
82 +[[image:https://wiki.dragino.com/images/thumb/d/d5/Single_CHAN_3.png/600px-Single_CHAN_3.png||height="237" width="600"]]
91 91  
92 92  Configure Gateway
93 93  
94 -
95 95  = 3. Recommand Gateway for LoRaWAN application =
96 96  
97 97  For connecting a standard LoRaWAN devices. Please use the recommend LoRaWAN gateway:
image-20220527164647-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -29.8 KB
Content
image-20220601111608-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -26.8 KB