Changes for page Limitation of the use of LG01/LG02 with LoRaWAN node
Last modified by Xiaoling on 2023/05/29 08:40
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -31,7 +31,6 @@ 31 31 32 32 = 2. Set Up Dragino End Node to work for Single Channel Gateway such as LG01/LG02 = 33 33 34 - 35 35 To work with single channel gateway, users need to set Dragino End Device to work in (% style="color:#037691" %)**ABP mode**(%%) and (% style="color:#037691" %)**transmit in only one frequency**. 36 36 37 37 ((( ... ... @@ -42,7 +42,6 @@ 42 42 43 43 == 2.1 Step1: Creat ABP device in LoRaWAN Server == 44 44 45 - 46 46 Log in TTN, Create an ABP device in the application and input the network session key (NETSKEY), app session key (APPSKEY) from the device. 47 47 48 48 [[image:image-20220527164521-1.png]] ... ... @@ -58,7 +58,6 @@ 58 58 59 59 == 2.2 Step2: Configure End Node radio parameters == 60 60 61 - 62 62 Run AT Command to make LoRaWAN End Node to work in Single frequency & ABP mode. Below is the AT commands: 63 63 64 64 * AT+FDR Reset Parameters to Factory Default, Keys Reserve ... ... @@ -69,27 +69,23 @@ 69 69 * AT+DADDR=26 01 1A F1 Set Device Address to 26 01 1A F1 ~-~-> Make sure this match Server setting 70 70 * ATZ Reset MCU 71 71 72 - 73 73 As shown in below: 74 74 75 -[[image:image -20220601111608-1.png]]71 +[[image:https://wiki.dragino.com/images/thumb/3/35/Single_CHAN_2.png/600px-Single_CHAN_2.png||height="400" width="600"]] 76 76 77 77 Configure Device 78 78 79 - 80 80 == 2.3 Step3: Configure Gateway == 81 81 82 - 83 83 Configure gateway so it can receive the packet sent from End Node: 84 84 85 85 * RX frequency: 868400000 ~-~-> Must same as the End Node AT+CHS settings. 86 86 * SF: 7 ~-~-> Must match the End Node DR settings. More about this please check [[LoRaWAN Region setting>>url:https://lora-alliance.org/sites/default/files/2018-07/lorawan_regional_parameters_v1.0.3reva_0.pdf]]. The End Node us EU868 frequency band, the DR5 equal to SF7/ Bandwidth 125Khz, so we need to set SF=7 here (ABove document Page 16). 87 87 88 -[[image:image -20220527164647-3.png]]82 +[[image:https://wiki.dragino.com/images/thumb/d/d5/Single_CHAN_3.png/600px-Single_CHAN_3.png||height="237" width="600"]] 89 89 90 90 Configure Gateway 91 91 92 - 93 93 = 3. Recommand Gateway for LoRaWAN application = 94 94 95 95 For connecting a standard LoRaWAN devices. Please use the recommend LoRaWAN gateway:
- image-20220527164647-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -29.8 KB - Content
- image-20220601111608-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -26.8 KB - Content