59 -
60 60  Run AT Command to make LoRaWAN End Node to work in Single frequency & ABP mode. Below is the AT commands:
61 61  
62 62  * AT+FDR Reset Parameters to Factory Default, Keys Reserve
... ... @@ -67,27 +67,23 @@
67 67  * AT+DADDR=26 01 1A F1 Set Device Address to 26 01 1A F1 ~-~-> Make sure this match Server setting
68 68  * ATZ Reset MCU
69 69  
70 -
71 71  As shown in below:
72 72  
73 -[[image:image-20220601111608-1.png]]
71 +[[image:image-20220527164615-2.png]]
74 74  
75 75  Configure Device
76 76  
77 -
78 78  == 2.3 Step3: Configure Gateway ==
79 79  
80 -
81 81  Configure gateway so it can receive the packet sent from End Node:
82 82  
83 83  * RX frequency: 868400000 ~-~-> Must same as the End Node AT+CHS settings.
84 84  * SF: 7 ~-~-> Must match the End Node DR settings. More about this please check [[LoRaWAN Region setting>>url:https://lora-alliance.org/sites/default/files/2018-07/lorawan_regional_parameters_v1.0.3reva_0.pdf]]. The End Node us EU868 frequency band, the DR5 equal to SF7/ Bandwidth 125Khz, so we need to set SF=7 here (ABove document Page 16).
85 85  
86 -[[image:image-20220527164647-3.png]]
82 +[[image:https://wiki.dragino.com/images/thumb/d/d5/Single_CHAN_3.png/600px-Single_CHAN_3.png||height="237" width="600"]]
87 87  
88 88  Configure Gateway
89 89  
90 -
91 91  = 3. Recommand Gateway for LoRaWAN application =
92 92  
93 93  For connecting a standard LoRaWAN devices. Please use the recommend LoRaWAN gateway:
image-20220601111608-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -26.8 KB
Content