Show last authors
1 **Table of Contents:**
2
3 {{toc/}}
4
5
6
7
8
9 = 1.  OverView =
10
11
12 In real-world deployment for LoRa, distance is a common topic. We always want to have the longest distance. This chapter shows some instructions for how to improve this.
13
14
15 = 2.  Analyze at the software side =
16
17 == 2.1  LoRa parameters that effect distance ==
18
19
20 Some settings in End Node will affect the transfer distance. They are:
21
22 * (% style="color:blue" %)**TXPower: **(%%)This means the output power from End Node. There is a command [[AT+TXP>>url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.14TransmitPower]] can be used to set the output power. TXP parameters follow the LoRaWAN regional document (rp2-1.0.3-lorawan-regional-parameters.pdf). Set to (% style="color:#037691" %)**AT+TXP=0**(%%) is always has the maximum output, but (% style="color:#037691" %)**AT+TXP=0**(%%) has different value in different frequency bands.
23
24 * (% style="color:blue" %)**Data Rate(DR): **(%%)This is a combination of Spreading Factor and Band Width. Lowest Data Rate (DR=0) always has the longest transmit distance in LoRaWAN protocol.
25
26 Below is the TXPower and DR table of EU868 Frequency band as reference.
27
28
29 [[image:image-20221006185826-1.png]]
30
31
32 [[image:image-20221006185826-2.png]]
33
34
35 Set (% style="color:#037691" %)**AT+TXP=0**(%%) **and** (% style="color:#037691" %)**AT+DR=0**(%%) will always has the longest transmit distance. But note that different frequency band has different TXP and DR coding according to LoRaWAN regional settings. Below is example for EU868, US915 and AS923 compare for example.
36
37
38 **End node actually value when TXP=0 and DR=0**
39
40 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:1002px" %)
41 |(% style="background-color:#4f81bd; color:white; width:134px" %)**Frequency band**|(% style="background-color:#4f81bd; color:white; width:400px" %)**Output Power in LoRa Module (consider 2dB antenna)**|(% style="background-color:#4f81bd; color:white; width:362px" %)(((
42 **Spreading Factor(Higher SF can transmit further)**
43 )))|(% style="background-color:#4f81bd; color:white; width:102px" %)**Band Width**
44 |(% style="width:134px" %)**EU868**|(% style="width:400px" %)14dBm|(% style="width:362px" %)SF=12|(% style="width:102px" %)125Khz
45 |(% style="width:134px" %)**US915**|(% style="width:400px" %)20 or 22 dBm (depends on max output of module)|(% style="width:362px" %)SF=10|(% style="width:102px" %)125Khz
46 |(% style="width:134px" %)**AS923**|(% style="width:400px" %)14dBm|(% style="width:362px" %)SF=12|(% style="width:102px" %)125Khz
47
48 == 2.2  Adaptive Data Rate (ADR) and set max distance ==
49
50
51 (% style="color:#037691" %)**ADR**(%%) is the feature that Server will ask End Node to adjust the TXP and DR according to some rules in the server. This is for the purpose of Network Management and Optimize End Node battery life-time.
52
53
54 By default, ADR is turn on((% style="color:#037691" %)**AT+ADR=1**) (%%)so End node ADR feature is enable.
55
56
57 (% style="color:blue" %)**Normally, user can set the max distance by setting:**
58
59 (% style="color:#037691" %)**AT+ADR=0**
60
61 (% style="color:#037691" %)**AT+DR=0     **~/~/(%%) Use longest distance modulation
62
63 (% style="color:#037691" %)**AT+TXP=0   **(%%)~/~/ Use max power   For EU868, max power can be is AT+TXP=50
64
65
66 This can be downlink via the LoRaWAN downlink command, see [[this link>>url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H8.2UseDownlinkCommandtosetafixuplinkDR]] for reference.
67
68
69 == 2.3  Check for short distance problem ==
70
71
72 According to the above technology, if we have a problem on the distance, we can first check if the end node is trying to longest distance modulation already. We can see that from the LoRaWAN server. Below is an example from Chirpstack.
73
74 We can see the traffic in gateway's page and know that the distance is SF12 / BW125. (note, server is not able to know Transmit Power settings from End Node)
75
76 [[image:image-20221006185826-3.png]]
77
78
79 == 2.4  Best software settings for the longest distance ==
80
81
82 Below are the settings for longest distance transmission. ( will reduce battery life)
83
84 * (% style="color:#037691" %)**AT+ADR=0**          (%%)~/~/  Disable ADR  (% style="color:#037691" %)**(downlinkpayload: 2200FFFF)**
85 * (% style="color:#037691" %)**AT+DR=0**           (%%)~/~/  Use the smallest DR,the longest distance modulation (% style="color:#037691" %)**(downlinkpayload: 220000FF)**
86 * (% style="color:#037691" %)**AT+TXP=0**          (%%)~/~/  Use max power   For EU868, max power can be is AT+TXP=50 (% style="color:#037691" %)** (downlinkpayload: 22000000)**
87
88
89
90 == 2.5 Debug in Software ==
91
92
93 Dragino can help client to debug the software for the distance issue. In the case , please send us below info:
94
95 * Detail packets include for Join Request, Join Accept, Uplink & Downlink, These packets should include:
96 ** RSSI, DataRate, FCNT, Frequency.
97 ** MIC command detail & Payload detail.
98
99
100 = 3.  Analyze at the hardware side =
101
102 == 3.1  Check if the antenna path is good ~-~- For LSN50v2 series end node ==
103
104
105 a) Open Enclosure and Check if the antenna connection to module is good.
106
107 b) check if the connector match.
108
109 [[image:image-20221016081725-1.png||height="426" width="706"]]
110
111
112 = 4.  Installation Guidelines =
113
114 == 4.1  Check the use environment ==
115
116
117 First , User should notice: Radio link quality and performances are highly dependent of the environment.Even you have the same hardware and antenna, Different installation will result in different performance.
118
119 (% style="color:blue" %)**Better performances can be reached with:**
120
121 * Outdoor environment.
122 * No obstacles.
123 * No high level radio interferes in the ISM band you use.
124 * At least 1 meter above the ground.
125
126 (% style="color:blue" %)**Radio performances are degraded with:**
127
128 * Obstacles: buildings, trees...
129 * Inner buildings environments.
130 * High ISM band usage by other technologies.
131 * Radio communication are usually killed with bad topographic conditions. It is usually not possible to communicate through a hill, even very small.
132
133
134
135 == 4.2  Improve the Antenna ==
136
137
138 In some case, we have to install the device inside the chamber or next to a metal case. So the signal between the antenna and the receiver (gateway) is blocked by the metal. This will greatly reduce the signal. In such case, we can consider using antenna extend cable to extend the antenna to a better position.
139
140
141 = 5.  Some real-world case =
142
143 == 5.1  Server reason cause end node has problem on Join. ==
144
145
146 In one case, the customer is using AWS IoT Core and gateway to connect to AWS via Basic Station Connection, Frequency Band is AU915 sub-band 2. For some unknown reason, AWS always set downlink power to 0dBm, which cause the gateway only emit a very low power and lead to a short distance for sensor.
147
148
149 Below is the output log in gateway side ( SSH Access to Gateway and Check Station log)
150
151 [[image:image-20221006185826-4.png]]
152
153
154 The fix of this issue is to set the output power to a high value even server ask to send out 0dBm.
155
156 Reference Link:  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Change%20Gateway%20Power/#H1.A0Overview>>http://wiki.dragino.com/xwiki/bin/view/Main/Change%20Gateway%20Power/#H1.A0Overview]]
157
158
159 == 5.2 Chirpstack Default settings to 64 channels which cause Signal Poor. ==
160
161
162 In this case, User use a Chirpstack LoRaWAN server with default settings. The Frequency Band is US915 and default settings of Chirpstack has all channels ( All sub-bands , total 72 channels) enable. User use a LDS03A and a LPS8N LoRaWAN gateway for the test.
163
164
165 There is a strange issue: LDS03 has a very good RSSI ( RSSI=-40) during OTAA Join. But The LDS03A give a very poor RSSI after OTAA Join. After debug, it proves that the issue is with ChirpStack Frequency band settings. The ChirpStack server enables all 72 channels and the LDS03A will also use all channels after OTAA Join, but the LPS8N only can support 8 channels and set to Sub-Band2. When the LDS03A sends an uplink packet in the channel LPS8N doesn't support, because LDS03A is very close to LPS8N, LPS8N pick up this not support frequency and send to server. So in the platform we see a uplink packet with very poor RSSI.
166
167
168 Above issue was confirmed and solved after set the ChirpStack support channels to sub-band2. See below for photos during debug.
169
170 [[image:image-20221031233628-2.png]]
171
172
173 [[image:image-20221031233759-3.png]]
174
175
176 [[image:image-20221101000006-1.png||height="353" width="931"]]
177
178
179 = 6. Use a repeater =
180
181
182 In some cases, user can consider use a repeater for limitation transmition.
183
184 See here for how to set up: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20All%20Gateway%20models/LoRaWAN%20IoT%20Kit%20v3%20User%20Manual/#H7.Example6:LimitedLoRaWANrelay >>http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20All%20Gateway%20models/LoRaWAN%20IoT%20Kit%20v3%20User%20Manual/#H7.Example6:LimitedLoRaWANrelay]]
185
186
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0