From version < 22.2 >
edited by Mengting Qiu
on 2023/11/16 17:18
To version < 20.1 >
edited by Edwin Chen
on 2023/02/08 10:20
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.ting
1 +XWiki.Edwin
Content
... ... @@ -4,8 +4,6 @@
4 4  
5 5  
6 6  
7 -
8 -
9 9  = 1.  OverView =
10 10  
11 11  
... ... @@ -37,18 +37,19 @@
37 37  
38 38  **End node actually value when TXP=0 and DR=0**
39 39  
40 -(% border="1.5" cellspacing="4" style="background-color:#f2f2f2; width:1002px" %)
41 -|(% style="background-color:#d9e2f3; width:134px" %)**Frequency band**|(% style="background-color:#d9e2f3; width:400px" %)**Output Power in LoRa Module (consider 2dB antenna)**|(% style="background-color:#d9e2f3; width:362px" %)(((
38 +(% border="1.5" cellspacing="4" style="background-color:#ffffcc; color:black; width:1002px" %)
39 +|(% style="width:134px" %)**Frequency band**|(% style="width:400px" %)**Output Power in LoRa Module (consider 2dB antenna)**|(% style="width:362px" %)(((
42 42  **Spreading Factor(Higher SF can transmit further)**
43 -)))|(% style="background-color:#d9e2f3; width:102px" %)**Band Width**
41 +)))|(% style="width:102px" %)**Band Width**
44 44  |(% style="width:134px" %)**EU868**|(% style="width:400px" %)14dBm|(% style="width:362px" %)SF=12|(% style="width:102px" %)125Khz
45 45  |(% style="width:134px" %)**US915**|(% style="width:400px" %)20 or 22 dBm (depends on max output of module)|(% style="width:362px" %)SF=10|(% style="width:102px" %)125Khz
46 46  |(% style="width:134px" %)**AS923**|(% style="width:400px" %)14dBm|(% style="width:362px" %)SF=12|(% style="width:102px" %)125Khz
47 47  
46 +
48 48  == 2.2  Adaptive Data Rate (ADR) and set max distance ==
49 49  
50 50  
51 -(% style="color:#037691" %)**ADR**(%%) is the feature that Server will ask End Node to adjust the TXP and DR according to some rules in the server. This is for the purpose of Network Management and Optimize End Node battery life-time.
50 +**ADR** is the feature that Server will ask End Node to adjust the TXP and DR according to some rules in the server. This is for the purpose of Network Management and Optimize End Node battery life-time.
52 52  
53 53  
54 54  By default, ADR is turn on((% style="color:#037691" %)**AT+ADR=1**) (%%)so End node ADR feature is enable.
... ... @@ -58,9 +58,9 @@
58 58  
59 59  (% style="color:#037691" %)**AT+ADR=0**
60 60  
61 -(% style="color:#037691" %)**AT+DR=0     **~/~/(%%) Use longest distance modulation
60 +(% style="color:#037691" %)**AT+DR=0**
62 62  
63 -(% style="color:#037691" %)**AT+TXP=0   **(%%)~/~/ Use max power   For EU868, max power can be is AT+TXP=50
62 +(% style="color:#037691" %)**AT+TXP=0**
64 64  
65 65  
66 66  This can be downlink via the LoRaWAN downlink command, see [[this link>>url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H8.2UseDownlinkCommandtosetafixuplinkDR]] for reference.
... ... @@ -83,21 +83,14 @@
83 83  
84 84  Below are the settings for longest distance transmission. ( will reduce battery life)
85 85  
86 -* (% style="color:#037691" %)**AT+ADR=0**          (%%)~/~/  Disable ADR  (% style="color:#037691" %)**(downlinkpayload: 2200FFFF)**
87 -* (% style="color:#037691" %)**AT+DR=0**         (%%)~/~/  Use the smallest DR,the longest distance modulation (% style="color:#037691" %)**(downlinkpayload: 220000FF)**
88 -* (% style="color:#037691" %)**AT+TXP=0**      (%%)~/~/  Use max power   For EU868, max power can be is AT+TXP=50 (% style="color:#037691" %)** (downlinkpayload: 22000000)**
85 +* (% style="color:#037691" %)**AT+ADR=0**     (%%)~/~/  Disable ADR
86 +* (% style="color:#037691" %)**AT+DR=  0**     (%%)~/~/  Use the smallest DR
87 +* (% style="color:#037691" %)**AT+TXP=0**    (%%) ~/~/  Use max power.
89 89  
90 -== 2.5 Debug in Software ==
91 91  
92 -Dragino can help client to debug the software for the distance issue. In the case , please send us below info:
93 -
94 -* Detail packets include for Join Request, Join Accept, Uplink & Downlink, These packets should include:
95 -** RSSI, DataRate, FCNT, Frequency.
96 -** MIC command detail & Payload detail.
97 -
98 98  = 3.  Analyze at the hardware side =
99 99  
100 -== 3.1  Check if the antenna path is good ~-~- For LSN50v2 series end node ==
92 +== 3.1  Check if the antenna path is good ~-~- For LSn50v2 series end node ==
101 101  
102 102  
103 103  a) Open Enclosure and Check if the antenna connection to module is good.
... ... @@ -129,6 +129,7 @@
129 129  * High ISM band usage by other technologies.
130 130  * Radio communication are usually killed with bad topographic conditions. It is usually not possible to communicate through a hill, even very small.
131 131  
124 +
132 132  == 4.2  Improve the Antenna ==
133 133  
134 134  
... ... @@ -176,7 +176,6 @@
176 176  
177 177  = 6. Use a repeater =
178 178  
179 -
180 180  In some cases, user can consider use a repeater for limitation transmition.
181 181  
182 182  See here for how to set up: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20All%20Gateway%20models/LoRaWAN%20IoT%20Kit%20v3%20User%20Manual/#H7.Example6:LimitedLoRaWANrelay >>http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20All%20Gateway%20models/LoRaWAN%20IoT%20Kit%20v3%20User%20Manual/#H7.Example6:LimitedLoRaWANrelay]]
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0