From version < 22.1 >
edited by Edwin Chen
on 2023/08/29 09:16
To version < 19.2 >
edited by Xiaoling
on 2022/12/29 17:40
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Edwin
1 +XWiki.Xiaoling
Content
... ... @@ -4,8 +4,6 @@
4 4  
5 5  
6 6  
7 -
8 -
9 9  = 1.  OverView =
10 10  
11 11  
... ... @@ -37,19 +37,20 @@
37 37  
38 38  **End node actually value when TXP=0 and DR=0**
39 39  
40 -(% border="1.5" cellspacing="4" style="background-color:#f2f2f2; width:1002px" %)
41 -|(% style="background-color:#d9e2f3; width:134px" %)**Frequency band**|(% style="background-color:#d9e2f3; width:400px" %)**Output Power in LoRa Module (consider 2dB antenna)**|(% style="background-color:#d9e2f3; width:362px" %)(((
38 +(% border="1.5" cellspacing="4" style="background-color:#ffffcc; color:black; width:1002px" %)
39 +|(% style="width:134px" %)**Frequency band**|(% style="width:400px" %)**Output Power in LoRa Module (consider 2dB antenna)**|(% style="width:362px" %)(((
42 42  **Spreading Factor(Higher SF can transmit further)**
43 -)))|(% style="background-color:#d9e2f3; width:102px" %)**Band Width**
41 +)))|(% style="width:102px" %)**Band Width**
44 44  |(% style="width:134px" %)**EU868**|(% style="width:400px" %)14dBm|(% style="width:362px" %)SF=12|(% style="width:102px" %)125Khz
45 45  |(% style="width:134px" %)**US915**|(% style="width:400px" %)20 or 22 dBm (depends on max output of module)|(% style="width:362px" %)SF=10|(% style="width:102px" %)125Khz
46 46  |(% style="width:134px" %)**AS923**|(% style="width:400px" %)14dBm|(% style="width:362px" %)SF=12|(% style="width:102px" %)125Khz
47 47  
48 48  
47 +
49 49  == 2.2  Adaptive Data Rate (ADR) and set max distance ==
50 50  
51 51  
52 -(% style="color:#037691" %)**ADR**(%%) is the feature that Server will ask End Node to adjust the TXP and DR according to some rules in the server. This is for the purpose of Network Management and Optimize End Node battery life-time.
51 +**ADR** is the feature that Server will ask End Node to adjust the TXP and DR according to some rules in the server. This is for the purpose of Network Management and Optimize End Node battery life-time.
53 53  
54 54  
55 55  By default, ADR is turn on((% style="color:#037691" %)**AT+ADR=1**) (%%)so End node ADR feature is enable.
... ... @@ -59,9 +59,9 @@
59 59  
60 60  (% style="color:#037691" %)**AT+ADR=0**
61 61  
62 -(% style="color:#037691" %)**AT+DR=0     **~/~/(%%) Use longest distance modulation
61 +(% style="color:#037691" %)**AT+DR=0**
63 63  
64 -(% style="color:#037691" %)**AT+TXP=0   **(%%)~/~/ Use max power   For EU868, max power can be is AT+TXP=50
63 +(% style="color:#037691" %)**AT+TXP=0**
65 65  
66 66  
67 67  This can be downlink via the LoRaWAN downlink command, see [[this link>>url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H8.2UseDownlinkCommandtosetafixuplinkDR]] for reference.
... ... @@ -84,23 +84,15 @@
84 84  
85 85  Below are the settings for longest distance transmission. ( will reduce battery life)
86 86  
87 -* (% style="color:#037691" %)**AT+ADR=0**      (%%)~/~/  Disable ADR
88 -* (% style="color:#037691" %)**AT+DR=  0**      (%%)~/~/  Use the smallest DR,the longest distance modulation
89 -* (% style="color:#037691" %)**AT+TXP=0**    (%%) ~/~/  Use max power   For EU868, max power can be is AT+TXP=50
86 +* (% style="color:#037691" %)**AT+ADR=0**     (%%)~/~/  Disable ADR
87 +* (% style="color:#037691" %)**AT+DR=  0**     (%%)~/~/  Use the smallest DR
88 +* (% style="color:#037691" %)**AT+TXP=0**    (%%) ~/~/  Use max power.
90 90  
91 91  
92 -== 2.5 Debug in Software ==
93 93  
94 -Dragino can help client to debug the software for the distance issue. In the case , please send us below info:
95 -
96 -* Detail packets include for Join Request, Join Accept, Uplink & Downlink, These packets should include:
97 -** RSSI, DataRate, FCNT, Frequency.
98 -** MIC command detail & Payload detail.
99 -
100 -
101 101  = 3.  Analyze at the hardware side =
102 102  
103 -== 3.1  Check if the antenna path is good ~-~- For LSN50v2 series end node ==
94 +== 3.1  Check if the antenna path is good ~-~- For LSn50v2 series end node ==
104 104  
105 105  
106 106  a) Open Enclosure and Check if the antenna connection to module is good.
... ... @@ -133,6 +133,7 @@
133 133  * Radio communication are usually killed with bad topographic conditions. It is usually not possible to communicate through a hill, even very small.
134 134  
135 135  
127 +
136 136  == 4.2  Improve the Antenna ==
137 137  
138 138  
... ... @@ -178,11 +178,6 @@
178 178  [[image:image-20221101000006-1.png||height="353" width="931"]]
179 179  
180 180  
181 -= 6. Use a repeater =
182 182  
183 183  
184 -In some cases, user can consider use a repeater for limitation transmition.
185 -
186 -See here for how to set up: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20All%20Gateway%20models/LoRaWAN%20IoT%20Kit%20v3%20User%20Manual/#H7.Example6:LimitedLoRaWANrelay >>http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20All%20Gateway%20models/LoRaWAN%20IoT%20Kit%20v3%20User%20Manual/#H7.Example6:LimitedLoRaWANrelay]]
187 -
188 188  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0