Table of Contents:
- 1. Introduction
- 2. How to use AT Commands or Downlink command
- 3. Support End Node and firmware version
- 4. System Management Commands
- 5. Keys, IDs and EUIs management
- 6. Joining and sending date on LoRaWAN network
- 7. LoRaWAN network management
- 7.1 Adaptive Data Rate
- 7.2 LoRa® Class
- 7.3 Duty Cycle Setting
- 7.4 Data Rate
- 7.5 Frame Counter Downlink
- 7.6 Frame Counter Uplink
- 7.7 Join Accept Delay1
- 7.8 Join Accept Delay2
- 7.9 Public Network Mode
- 7.10 Receive Delay1
- 7.11 Receive Delay2
- 7.12 Rx2 Window Data Rate
- 7.13 Rx2 Window Frequency
- 7.14 Transmit Power
- 7.15 RSSI of the Last Received Packet
- 7.16 SNR of the Last Received Packet
- 7.17 Application Port
- 7.18 Single Channel Mode
- 7.19 Eight Channel Mode
- 7.20 Get or Set RXwindows1 timeout
- 7.21 Get or Set RXwindows2 timeout
- 7.22 Setting up uplinkdwelltime (as923, au915)
- 7.23 Set Packet Receiving Response Level
- 7.24 Controls NBTrans in unconfirmed uplink mode(LWS007 NBTrans:Set retransmission packets)
- 7.25 Device offline rejoining (LWS007)
- 7.26 Request the server to send an ACK
- 7.27 Adjust network rejoining interval
- 8. AT Commands Combination
1. Introduction
Dragino LoRaWAN End Node support two types of AT Commands and Downlink Commands:
- Common Commands: They should be available for each sensor, such as: change uplink interval, reset device.
- Sensor Related Commands: Only for special sensor, such as control relay, poll RS485 device.
This page shows the common commands since Dragino LoRaWAN stack DR-LWS-005. Make sure the end node support stack higher than DR-LWS-005 before checking this page.
2. How to use AT Commands or Downlink command
- AT Command : See Devices User Manual for how to connect to device via USB TTL adapter and use. The user manual can be found in each product page of Dragino Official Website
- LoRaWAN Downlink Command: The gateway transfer downlink command in HEX format. This page shows the Downlink Command In HEX format. Please note some LoRaWAN servers use base64 as downlink code so user need to convert HEX to Base64 and use. Below are references for how to use downlink command:
- Use HEX format to send a downlink: TTN v3
- Use Base64 format to send a downlink: Chirpstack, How to Convert?
- See use note for more serves Servers Note(IoT LoRaWAN Server)
3. Support End Node and firmware version
Dragino STM32 base hardware Firmware / LoRaWAN stack list | ||
---|---|---|
Model | Description | Firmware Version <--> Stack Version |
Open Source Generic LoRaWAN Sensor Node | LSN50 v1.6.0 <--> DR-LWS-003; LSN50 v1.7.0 <--> DR-LWS-005; --> Support since this version | |
LoRaWAN GPS Tracker | LGT92 v1.6.3 <--> DR-LWS-003; LGT92 v1.6.4 <--> DR-LWS-005;--> Support since this version | |
LBT1, | LoRaWAN BLE Indoor Tracker | LBT1 v1.0 <--> DR-LWS-005; |
LoRaWAN RS485 Modbus Converter | RS485-LN v1.3 <--> DR-LWS-005; | |
LoRaWAN Temperature & Humidity Sensor | LHT65 v1.7 <--> DR-LWS-003; LHT65 v1.8.0 <--> DR-LWS-005;--> Support since this version |
4. System Management Commands
4.1 Change Uplink Interval
Feature: Change LoRaWAN End Node Transmit Interval.
AT Command: AT+TDC
AT+TDC | ||
---|---|---|
Command Example | Function | Response |
AT+TDC=? | Show current transmit Interval | 30000 OK the interval is 30000ms = 30s |
AT+TDC=60000 | Set Transmit Interval | OK Set transmit interval to 60000ms = 60 seconds |
Downlink Command: 0x01
Format: Command Code (0x01) followed by 3 bytes time value.
If the downlink payload=0100003C, it means set the END Node's Transmit Interval to 0x00003C=60(S), while type code is 01.
- Example 1: Downlink Payload: 0100001E // Set Transmit Interval (TDC) = 30 seconds
- Example 2: Downlink Payload: 0100003C // Set Transmit Interval (TDC) = 60 seconds
4.2 Reboot End Node
Feature: Reboot End Node to perform a new OTAA or ABP Join.
AT Command: ATZ
ATZ: Trig a reset of the MCU | ||
---|---|---|
Command Example | Function | Response |
ATZ | Reset MCU | Device reset and show booting info LSN50 Device/LoRa ST Module Image Version: XX Frequency Band: XX DevEui= XX XX XX XX XX XX XX XX <followed by the Tx and Rx information> |
Downlink Command: 0x04
Format: Command Code (0x04) followed by FF.
If the downlink payload=04FF, the end node will reboot.
4.3 Reset to factory Default
Feature: Reset the parameters to Factory Default, factory default value depends on the firmware settings, the OTAA and ABP keys will reserve after this command.
AT Command: AT+FDR
Reset to factory default | ||
---|---|---|
Command Example | Function | Response |
AT+FDR | Reset to factory default | Device reset to factory default parameters and show booting info LSN50 Device/LoRa ST Module Image Version: XX Frequency Band: XX DevEui= XX XX XX XX XX XX XX XX Please set the parameters or reset Device to apply change |
Downlink Command: 0x04
Format: Command Code (0x04) followed by FE.
If the downlink payload=04FE, Reset Parameters to Factory Default, Keys Reserve.
4.4 Show Firmware Version
Feature: Show firmware version. No downlink command yet.
AT Command: AT+VER
AT+VER: Image Version and Frequency Band | ||
---|---|---|
Command Example | Function | Response |
AT+VER=? | Show Image version and Frequency Band | 1.3 EU868 OK |
Downlink Command: 0x26 (Valid in 006 stack)
Downlink Format: 0x26
Device will reply with firmware version info, device info. frequency band info. detail please check device user manual. Total 5 bytes Example: If device is of firmware version 1.1.0 Upload: xx -- yy -- zz -- 110 total 5 bytes
xx: Software Type:
- 0x00 01: LGT92 Version
- 0x00 02: LBT1
- 0x00 03: LSE01/LDDS75/LDDS20/LSPH01/LLMS01/LSNPK01
yy: Frequency Band:
- 0x01: EU868
- 0x02: US915
- 0x03: IN865
- 0x04: AU915
- 0x05: KZ865
- 0x06: RU864
- 0x07: AS923
- 0x08: AS923-1
- 0x09: AS923-2
- 0xa0: AS923-3
zz: Subband
firmware version: v1.1.0 --> 110
4.5 Show System Configure
Feature: Show All configure. No downlink command yet.
AT Command: AT+CFG
AT+CFG: Print all configurations | ||
---|---|---|
Command Example | Function | Response |
AT+CFG | Show all configures | AT+DEUI = XX XX XX XX XX XX XX XX AT+DADDR=XXXXXXXX ………. AT+RX2WTO=X AT+CHS=868100000 OK |
5. Keys, IDs and EUIs management
5.1 Application EUI
Feature: Get or Set the Application EUI.
AT Command: AT+APPEUI
AT+APPEUI | ||
---|---|---|
Command Example | Function | Response |
AT+APPEUI=? | Get the Application EUI | 00 b3 d5 00 00 00 00 00 OK |
AT+APPEUI=00 b3 d5 7e f0 00 4d 34 | Set the Application EUI | OK |
5.2 Application Key
Feature: Get or Set the Application Key.
AT Command: AT+APPKEY
AT+APPKEY | ||
---|---|---|
Command Example | Function | Response |
AT+APPKEY=? | Get the Application Key | 00 35 55 55 22 23 55 53 43 24 23 42 34 35 35 35 OK |
AT+APPKEY=00 35 55 55 22 23 55 53 43 24 23 42 34 35 35 35 | Set the Application Key | OK |
5.3 Application Session Key
Feature: Get or Set the Application Session Key.
AT Command: AT+APPSKEY
AT+APPSKEY | ||
---|---|---|
Command Example | Function | Response |
AT+APPSKEY=? | Get the Application Session Key | 00 7d dc 73 33 d3 eb 9e 14 38 d5 a4 3e 62 5b e2 OK |
AT+APPSKEY=00 7d dc 73 33 d3 eb 9e 14 38 d5 a4 3e 62 5b e2 | Set the Application Session Key | (While Error in format, return AT_PARAM_ERROR) OK |
5.4 Device Address
Feature: Get or Set the Device Address.
AT Command: AT+DADDR
AT+DADDR | ||
---|---|---|
Command Example | Function | Response |
AT+DADDR=? | Get the Application Session Key. | (While Error in format, return AT_PARAM_ERROR) A8 40 41 FF OK |
AT+DADDR=A8 40 41 FF | Set the Application Session Key. | OK |
5.5 Device EUI
Feature: Get or Set the Device EUI.
AT Command: AT+DEUI
AT+DEUI | ||
---|---|---|
Command Example | Function | Response |
AT+DEUI=? | Get the Device EUI. | 00 44 34 22 33 45 55 55 OK |
AT+DEUI=A8 40 41 FF FF 12 34 56 | Set the Device EUI. | (System will write new value to Device EUI,While Error in format, return AT_PARAM_ERROR) OK |
5.6 Network ID
Feature: Get or Set the Network ID.(You can enter this command change only after successful network connection)
AT Command: AT+NWKID
AT+NWKID | ||
---|---|---|
Command Example | Function | Response |
AT+NWKID=? | Get the Network ID. | a8 40 41 ff OK |
AT+NWKID=A8 40 41 FF | Set the Network ID. | OK |
5.7 Network Session Key
Feature: Get or Set the Network Session Key
AT Command: AT+NWKSKEY
AT+NWKSKEY | ||
---|---|---|
Command Example | Function | Response |
AT+NWKSKEY=? | Get the Network Session Key. | 00 4f 19 25 52 ce 97 09 d7 fa 84 71 db 51 02 92 OK |
AT+NWKSKEY=A8 40 41 FF FF 12 34 56 00 01 02 04 05 06 06 07 | Set the Network Session Key. | OK |
6. Joining and sending date on LoRaWAN network
6.1 Confirm Mode
6.1.1 AT+CFM command before DR-LWS007 software stack
Feature: Get or Set the confirmation mode (0-1).
AT Command: AT+CFM
AT+CFM | ||
---|---|---|
Command Example | Function | Response |
AT+CFM=? | Get the confirmation mode | 0 OK |
AT+CFM=1 | Set the confirmation mode | OK |
AT+CFM=2 | Set the confirmation mode | While Error in format, return AT_PARAM_ERROR |
Downlink Command: 0x05
Format: Command Code (0x05) followed by 2 bytes mode value.
If the downlink payload=0501, it means set end node to use confirm mode, while type code is 05.
- Example 1: Downlink Payload: 0501 // Set AT+CFM=1
- Example 2: Downlink Payload: 0500 // Set AT+CFM=0
6.1.2 AT+CFM command since DR-LWS007 software stack
AT Command: AT+CFM
AT+CFM | ||
---|---|---|
Command Example | Function | Response |
AT+CFM=1,0,0 value1 | confirmed uplink | 1 OK |
AT+CFM=0,?,0 value2 | set max retry , range: 0 ~ 7 | 0~7 OK |
AT+CFM=0,0,1 value3 | uplink fcnt increase by 1 for each retry | 1 OK |
Downlink Command: 0x05
Format: Command Code (0x05) followed by 2 bytes mode value.
If the downlink payload=05010101, it means set end node to use confirm mode, while type code is 05.
- Example 1: Downlink Payload: 05010101 // Set AT+CFM=1,1,1
- Example 2: Downlink Payload: 05000700 // Set AT+CFM=0,7,0
6.2 Confirm Status
Feature: Get confirmation status of the last AT+SEND (0-1).
AT Command: AT+CFS
AT+CFS | ||
---|---|---|
Command Example | Function | Response |
AT+CFS=? | Get confirmation status | 0 OK |
6.3 Join LoRa® Network
Feature: Join network.
AT Command: AT+JOIN
AT+JOIN | ||
---|---|---|
Command Example | Function | Response |
AT+JOIN ? | Get imformation. | AT+JOIN: Join network OK While Error in format, return AT_BUSY_ERROR |
6.4 LoRa® Network Join Mode
Feature: Get or Set the Network Join Mode. (0: ABP, 1: OTAA).
AT Command: AT+NJM
AT+NJM | ||
---|---|---|
Command Example | Function | Response |
AT+NJM=? | Get the Network Join Mode | 1 OK |
AT+NJM=0 | Set the Network Join Mode | OK |
AT+NJM=2 | Set the Network Join Mode | While Error in format, return AT_PARAM_ERROR |
Downlink Command: 0x20
Format: Command Code (0x20) followed by 1 bytes mode value.
If the downlink payload=2000, it means set the Network Join Mode, while type code is 20.
- Example 1: Downlink Payload: 2000 // Set AT+NJM=0
- Example 2: Downlink Payload: 2001 // Set AT+NJM=1
6.5 LoRa® Network Join Status
Feature: LoRa® Network Join Status.
AT Command: AT+NJS
AT+NJS | ||
---|---|---|
Command Example | Function | Response |
AT+NJS=? | Get the join status. | 0 OK |
6.6 Print Last Received Data in Raw Format
Feature: Print Last Received Data in Raw Format<port:data>.
AT Command: AT+RECV
AT+RECV | ||
---|---|---|
Command Example | Function | Response |
AT+RECV=? | print last received data in raw format. | 0: OK |
6.7 Print Last Received Data in Binary Format
Feature: Print Last Received Data in Binary Format<port:data>.
AT Command: AT+RECVB
AT+RECVB | ||
---|---|---|
Command Example | Function | Response |
AT+RECVB=? | print last received data in binary format (with hexadecimal values). | 2: 0010 OK |
6.8 Send Text Data
Feature: Send Text Data<port:data>.
AT Command: AT+SEND
AT+SEND | ||
---|---|---|
Command Example | Function | Response |
AT+SEND=12:hello world | Send text data along with the application port. | OK While Error in format, return AT_BUSY_ERROR/AT_BUSY_ERROR/AT_NO_NETWORK_JOINED
|
6.9 Send Hexadecimal Data
Feature: Send hexadecimal data along with the application port.
AT Command: AT+SENDB
AT+SENDB | ||
---|---|---|
Command Example | Function | Response |
AT+SENDB=12:abcdef0123456789 | Send hexadecimal data along with the application port. | OK |
AT+SENDB=abcdef0123456789 | Send hexadecimal data along with the application port. | While Error in format, return AT_PARAM_ERROR AT_BUSY_ERROR/AT_NO_NETWORK_JOINED
|
7. LoRaWAN network management
7.1 Adaptive Data Rate
Feature: Get or Set the Adaptive Data Rate setting. (0: off, 1: on).
AT Command: AT+ADR
AT+ADR | ||
---|---|---|
Command Example | Function | Response |
AT+ADR=? | Get the Adaptive Data Rate setting. | 1 OK |
AT+ADR=0 | Set the Adaptive Data Rate setting. | OK |
AT+ADR=2 | Set the Adaptive Data Rate setting. | While Error in format, return AT_PARAM_ERROR |
Downlink Command: 0x22
If the downlink payload=2201, it means setting the adaptive data rate to 1, while type code is 22.
- Example 1: Downlink Payload: 2201 // Set AT+ADR=1.
- Example 2: Downlink Payload: 2200FFFF // Set AT+ADR=0.
7.2 LoRa® Class
Feature: Get or Set the Device Class(Currently only support class A, class C).
AT Command: AT+CLASS
AT+CLASS | ||
---|---|---|
Command Example | Function | Response |
AT+CLASS=? | Get the Device Class. | A OK |
AT+CLASS=C | Set the Device Class. | OK
|
7.3 Duty Cycle Setting
Feature: Get or Set the ETSI Duty Cycle setting - 0=disable, 1=enable - Only for testing.
AT Command: AT+DCS
AT+DCS | ||
---|---|---|
Command Example | Function | Response |
AT+DCS=? | Get the ETSI Duty Cycle setting. | 1 OK |
AT+DCS=1 | Set the ETSI Duty Cycle setting. | OK
|
7.4 Data Rate
Feature: Get or Set the Data Rate. (0-7 corresponding to DR_X) .
Notice:
- User need to set Adaptive Data Rate(ADR)=0 first. otherwise device will respond to server's ADR command and change the DR according to server auto-adjustment.
- Data Rate specifies Spreading Factor. The mapping varies in different frequency bands. User can check this link for detail. rp2-1.0.3-lorawan-regional-parameters.pdf
AT Command: AT+DR
AT+DR | ||
---|---|---|
Command Example | Function | Response |
AT+DR=? | Get the Data Rate. | 5 OK |
AT+DR=2 | Set the Data Rate. | OK
|
Downlink Command: 0x2200aaFF
If the downlink payload=220001FF, it means setting the data rate to 1, while type code is 22 00 aa FF.
- Example 1: Downlink Payload: 220001FF // Set AT+DR=1.
- Example 2: Downlink Payload: 220000FF // Set AT+DR=0.
7.5 Frame Counter Downlink
Feature: Get or Set the Frame Counter Downlink.
AT Command: AT+FCD
AT+FCD | ||
---|---|---|
Command Example | Function | Response |
AT+FCD=? | Get the Frame Counter Downlink. | 0 OK |
AT+FCD=10 | Set the Frame Counter Downlink. | (System will write new value to FCD) OK |
7.6 Frame Counter Uplink
Feature: Get or Set the Frame Counter Uplink.
AT Command: AT+FCU
AT+FCU | ||
---|---|---|
Command Example | Function | Response |
AT+FCU=? | Get the Frame Counter Uplink. | 0 OK |
AT+FCU=10 | Set the Frame Counter Uplink. | OK
|
7.7 Join Accept Delay1
Feature: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 1 in ms.
AT Command: AT+JN1DL
AT+JN1DL | ||
---|---|---|
Command Example | Function | Response |
AT+JN1DL=? | Get the Join Accept Delay. | 5000 OK |
AT+JN1DL=10000 | Set the Join Accept Delay. | OK
|
7.8 Join Accept Delay2
Feature: Get or Set the Join Accept Delay between the end of the Tx and the Join Rx Window 2 in ms.
AT Command: AT+JN2DL
AT+JN2DL | ||
---|---|---|
Command Example | Function | Response |
AT+JN2DL=? | Get the Join Accept Delay. | 6000 OK |
AT+JN2DL=20000 | Set the Join Accept Delay. | OK
|
7.9 Public Network Mode
Feature: Get or Set the public network mode. (0: off, 1: on). A Public LoRaWAN network use 0x34 as syncword. Default Settings; PNM=1
Notice: If user build their own LoRaWAN server but still use syncword=0x34, this is still considered a public LoRaWAN network.
AT Command: AT+PNM
AT+PNM | ||
---|---|---|
Command Example | Function | Response |
AT+PNM=? | Get the public network mode. | 1 OK |
AT+PNM=1 | Set the public network mode. Set syncword=0x34 | (System will write new value to PNM) OK
|
AT+PNM=0 | Set to use private network autoset syncword=0x12 |
7.10 Receive Delay1
Feature: Get or Set the delay between the end of the Tx and the Rx Window 1 in ms
AT Command: AT+RX1DL
AT+RX1DL | ||
---|---|---|
Command Example | Function | Response |
AT+RX1DL=? | Get the delay. | 1000 OK |
AT+RX1DL=1500 | Set the delay. | OK
|
7.11 Receive Delay2
Feature: Get or Set the delay between the end of the Tx and the Rx Window 2 in ms
AT Command: AT+RX2DL
AT+RX2DL | ||
---|---|---|
Command Example | Function | Response |
AT+RX2DL=? | Get the delay. | 2000 OK |
AT+RX2DL=2500 | Set the delay. | OK
|
7.12 Rx2 Window Data Rate
Feature: Get or Set the Rx2 window data rate (0-7 corresponding to DR_X)
AT Command: AT+RX2DR
AT+RX2DR | ||
---|---|---|
Command Example | Function | Response |
AT+RX2DR=? | Get the Rx2 window data rate. | 2 OK |
AT+RX2DR=6 | Set the Rx2 window data rate. | OK
|
7.13 Rx2 Window Frequency
Feature: Get or Set the Rx2 window frequency
AT Command: AT+RX2FQ
AT+RX2FQ | ||
---|---|---|
Command Example | Function | Response |
AT+RX2FQ=? | Get the Rx2 window frequency. | 434665000 OK |
AT+RX2FQ=434665000 | Set the Rx2 window frequency. | OK
|
7.14 Transmit Power
Feature: Get or Set the Transmit Power(0-5, MAX:0, MIN:5, according to LoRaWAN Spec, or 40=10dB, 41 = 11dB, …, 50 = 20dB which is out of LoRaWAN spec. )
Notice: Transmit Power might be changed by ADR from LoRaWAN server. So manually change TXP also remember to set AT+ADR=0 in sensor
AT Command: AT+TXP
AT+TXP | ||
---|---|---|
Command Example | Function | Response |
AT+TXP=? | Get the Transmit Power. | 0 OK |
AT+TXP=1 | Set the Transmit Power. | OK
|
Downlink Payload. The 4th byte of 0x22 downlink.
If the downlink payload=22000100, it means setting the TXP to 0.
- Example 1: Downlink Payload: 22000102 // Set AT+TXP=2.
- Example 2: Downlink Payload: 220000FF // Set AT+TXP=0.
7.15 RSSI of the Last Received Packet
Feature: Get or Set the Rx2 window frequency
AT Command:AT+RSSI
AT+RSSI | ||
---|---|---|
Command Example | Function | Response |
AT+RSSI=? | Get the RSSI of the last received packet. | 0 OK |
7.16 SNR of the Last Received Packet
Feature: Get the SNR of the last received packet
AT Command: AT+SNR
AT+SNR | ||
---|---|---|
Command Example | Function | Response |
AT+SNR=? | Get the RSSI of the last received packet. | 0 OK |
7.17 Application Port
Feature: Get or set the application port.
AT Command: AT+PORT
AT+PORT | ||
---|---|---|
Command Example | Function | Response |
AT+PORT=? | Get the application port | 21 OK |
AT+PORT=21 | Set the application port | OK |
Downlink Command: 0x23
Format: Command Code (0x23) followed by 1 bytes port value.
If the downlink payload=2301, it means set the application port to 1, while type code is 23.
- Example 1: Downlink Payload: 2301 // set the application port to 1
- Example 2: Downlink Payload: 2305 // set the application port to 5
7.18 Single Channel Mode
Feature:Get or Set Frequency (Unit: Hz) for Single Channel Mode.
AT Command: AT+CHS
AT+CHS | ||
---|---|---|
Command Example | Function | Response |
AT+CHS=? | Get Frequency for Single Channel Mode | 0 OK |
AT+CHS=868100000 | Set Frequency for Single Channel Mode | OK |
7.19 Eight Channel Mode
Feature: Get or Set eight channels mode,Only for US915,AU915,CN470.
AT Command: AT+CHE
AT+CHE | ||
---|---|---|
Command Example | Function | Response |
AT+CHE=? | Get eight channels mode | 1 902.3 902.5 902.7 902.9 903.1 903.3 903.5 903.7 OK |
AT+CHE=1 | Set eight channels mode | OK |
Downlink Command: 0x24 (LHT65,LHT65N Downlink Command:0x07)
Format: Command Code (0x24) followed by 1 bytes channel value.
If the downlink payload=2401, it means set channel mode to 1, while type code is 24.
- Example 1: Downlink Payload: 2401 // set channel mode to 1
- Example 2: Downlink Payload: 2405 // set channel mode to 5
7.20 Get or Set RXwindows1 timeout
Feature: Get or Set the number of symbols to detect and timeout from RXwindow1(0 to 255).
AT Command: AT+RX1WTO
AT+ RX1WTO | ||
---|---|---|
Command Example | Function | Response |
AT+RX1WTO=? | Get RXwindows1 timeout | 14 OK |
AT+RX1WTO=60 | Set RXwindows1 timeout | OK |
AT+RX1WTO is theRxSingle timeout value of receive window 1. If it is not set, then the queriedvalue is the default value. If it is set, then the queried value is the setvalue. AT+RX2TWO is thesame as above. The definitionof RxSingle timeout is as described in the following paragraph.
Increasing thisvalue is equal to extending the time that the receiving window is opened, butthe corresponding power consumption will also increase. Properly increasingthis value can increase the success rate of the downlink.
7.21 Get or Set RXwindows2 timeout
Feature: Get or Set the number of symbols to detect and timeout from RXwindow2(0 to 255).
AT Command: AT+RX2WTO
AT+ RX2WTO | ||
---|---|---|
Command Example | Function | Response |
AT+RX2WTO=? | Get RXwindows2 timeout | 7 OK |
AT+RX2WTO=20 | Set RXwindows2 timeout | OK |
7.22 Setting up uplinkdwelltime (as923, au915)
Feature: Get or Set uplinkdwelltime
AT Command: AT+DWELLT
AT+DWELLT | ||
---|---|---|
Command Example | Function | Response |
AT+DWELLT=? | Get uplinkdwelltime | 1 OK |
AT+DWELLT=0 | Set uplinkdwelltime | OK |
Downlink Command: 0x25
Format: Command Code (0x25) followed by 1 bytes state value.
If the downlink payload=2501, it means set uplinkdwelltime to 1, while type code is 25.
- Example 1: Downlink Payload: 2501 // set uplinkdwelltime to 1
- Example 2: Downlink Payload: 2500 // set uplinkdwelltime to 0
7.23 Set Packet Receiving Response Level
Feature: Get or Set packet receiving response level. This feature is used to set compatible with different LoRaWAN servers. If RPL doesn;t match , user will see strange message in the server portal.
RPL value:
- AT+RPL=0: Device won't immediately reply any downlink commands from platform.
- AT+RPL=1: Device will immediately reply message to Unconfirmed Data Down. Payload is 0x00.
- AT+RPL=2: Device will immediately reply message to Confirmed Data Down. Payload is 0x00 and requied response header for this command.
- AT+RPL=3: Device will immediately reply message to MAC Command. Payload is 0x00 and requied response header for this command.
- AT+RPL=4: Device will immediately reply message to Confirmed Data Down & MAC Command. Payload is 0x00 and requied response header for these two commands.
Case Analyes:
- For Class A devices, AT+RPL=0 is ok. that is defaut settings in software.
- For Class C devices used in ChirpStack, need to set AT+RPL=4 because Chirpstack require immedietely reply message to MAC Command.
- For Class C devices used in TTI, need to set AT+RPL=4 because TTI require immediately reply message to Confirmed Data Down & MAC Command.
AT Command: AT+RPL
AT+RPL | ||
---|---|---|
Command Example | Function | Response |
AT+RPL=? | Get packet receiving response level | 1 OK |
AT+RPL=0 | Set packet receiving response level | OK |
Downlink Command: 0x21
Format: Command Code (0x21) followed by 1 bytes level value.
If the downlink payload=2101, it means set packet receiving response level to 1, while type code is 21.
- Example 1: Downlink Payload: 2101 // set packet receiving response level to 1
- Example 2: Downlink Payload: 2102 // set packet receiving response level to 2
7.24 Controls NBTrans in unconfirmed uplink mode(LWS007 NBTrans:Set retransmission packets)
AT Command: AT+SETMAXNBTRANS
AT+SETMAXNBTRANS | ||
---|---|---|
Command Example | Function | Response |
AT+SETMAXNBTRANS=1,0 | Value1: set the maximum NBTrans. | 1 OK |
AT+SETMAXNBTRANS=?,1 | value2: 0: uplink fcnt doesn't change for each NBTrans; 1: uplink fcnt increase by 1 for each NBTrans. | 1 OK |
Downlink Command: 0x33
Format: Command Code (0x33) followed by 2 bytes mode value.
If the downlink payload=330100, it means set end node to use confirm mode, while type code is 33.
- Example 1: Downlink Payload: 330100 // Set AT+SETMAXNBTRANS=1,0
- Example 2: Downlink Payload: 330201 // Set AT+SETMAXNBTRANS=2,1
7.25 Device offline rejoining (LWS007)
AT Command: AT+DDETECT
AT+DDETECT=<Flag>,<ACK_Timout_1>,<ACK_Timout_2> (Default Value: AT+DDETECT=1,1440,2880)
- ACK_Timout_1: Unit: min
- ACK_Timout_2: Unit: min
AT+DDETECT | ||
---|---|---|
Command Example | Function | Response |
AT+DDETECT=1,1440,2880 value1 | Enable online detect | 1 OK |
AT+DDETECT=1,?,2880 value2 | Online detection packet sending time |
OK |
AT+DDETECT=1,1440,? value3 | Process rejoin |
OK |
Downlink Command: 0x32
Format: Command Code (0x32) followed by 2 bytes mode value.
If the downlink payload=320105A00B40, it means set end node to use confirm mode, while type code is 32.
- Example 1: Downlink Payload: 320105A00B40 // Set AT+DDETECT=1,1440,2880
- 0x01 : Flag
- 0x05A0: ACK_Timout_1 : 1440minutes (24 hours)
- 0x0B40: ACK_Timout_2 : 2880minutes (48 hours)
- Explain: Enable Online Detect, if end node doesn't receive any downlink within ACK_Timout_1( 1440 minutes or 24 hours). End node will use confirmed uplink to send packets during ACK_Timout_1 (the 24th hour) to ACK_Timout_2 ( the 48th hour). If from the 24th to 48th hour, end node got an downlink from server, it will switch back to unconfirmed uplink. end node will restart ACK_Timout_1. If from the 24th to 48th hour, end node still not got any downlink, means device doesn't get ACK from server within last 48 hours. Device will process rejoin, rejoin request interval is AT+RJTDC period. For AU915/ US915, device will use the sub-band used for last join.
7.26 Request the server to send an ACK
AT Command: AT+PNACKMD
AT+PNACKMD | ||
---|---|---|
Command Example | Function | Response |
AT+PNACKMD=1 | If the node uploads the ACK as confirm, it will request the server to send an ACK. If the server ack is not received, the node will upload the packets that have not received the ACK the next time it receives the ACK | 1 OK |
AT+PNACKMD=0 | off request the server to send an ACK | 0 OK |
7.27 Adjust network rejoining interval
AT Command: AT+RJTDC
AT+RJTDC | ||
---|---|---|
Command Example | Function | Response |
AT+RJTDC=? | Show the ReJoin data transmission interval in min | 30 OK the interval is 30 min |
AT+RJTDC=60 | Set the ReJoin data transmission interval in min | OK Set the ReJoin data transmission interval to 60 min |
Downlink Command: 0x26
Format: Command Code (0x26) followed by 2 bytes mode value.
If the downlink payload=26000A, it means set end node to use confirm mode, while type code is 26.
- Example 1: Downlink Payload: 26000A // Set AT+RJTDC=10
- Example 2: Downlink Payload: 260002 // Set AT+RJTDC=2
8. AT Commands Combination
8.1 Set a fix RX2DR for downlink window
- AT+ADR=0 --> Disable ADR first
- AT+RX2DR=xxxx --> Set xxxx to your wanted DataRate
8.2 Use Downlink Command to set a fix uplink DR
Downlink Command: 0x22000500
Same as: