<
From version < 9.1 >
edited by Kilight Cao
on 2022/06/23 11:55
To version < 6.1 >
edited by Edwin Chen
on 2022/06/20 17:46
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Kilight
1 +XWiki.Edwin
Content
... ... @@ -1,15 +1,10 @@
1 -= Overview: =
1 += Introduction =
2 2  
3 -In LoRaWAN protocol, the gateway transmit packet uses the output power base on the Power Index from the LoRaWAN server downlink. for example, the LoRaWAN server sends a downlink with this info "rf_power=14", gateway got this info and it will search the index for rf_power=14 and use the related rf setting to set output power. In some cases, the LoRaWAN server might set the rf-power to a quite low value ( for example 0dB) which is not practical for use. In such a case, the User can manually change the rf_power=0's rf settings to a higher power out. Below are the methods.
4 -
5 -
6 -= Change Power for Semtech UDP Paket forward connection =
7 -
8 8  ----
9 9  
10 -In LoRaWAN protocol, the gateway output power refers to the downstream packets sent by Gateway. This output power is controlled by the LoRaWAN server.
5 +In LoRaWAN protocol, the gateway output power refer to the downstream packets sent by Gateway. This output power is controlled by LoRaWAN server.
11 11  
12 -Gateway maintains a power index in the file: /etc/lora/global_conf.json for example:
7 +Gateway maintain a power index in the file: /etc/lora/global_conf.json for example:
13 13  
14 14  
15 15  (% class="box" %)
... ... @@ -29,22 +29,11 @@
29 29   "dig_gain": 0
30 30  )))
31 31  
32 -(% class="mark" %)Note: If when lorawan server specifies a rf_power that is not listed above. gateway will choose the closest power. profile.
27 +(% class="mark" %)Note: If when lorawan server specify a rf_power which is not list above. gateway will choose the closest power. profile.
33 33  
34 34  
35 -When the LoRaWAN server sends a downlink stream, the server will also ask the gateway to use rf_power as output. So users don't need to consider controlling on the gateway side.
30 +When LoRaWAN server sends a downlink stream, server will also ask the gateway to use which rf_power as output. So user don't need to consider to control in the gateway side.
36 36  
37 -If users want to always use a higher power or a lower power. Users can modify the pa_gain,mix_gain, and dig_gain to specify rf_power to achieve this purpose. This is not recommended, because this might break the regulator for a specific country.
32 +If user want to always use a higher power or a lower power. User can modify the pa_gain,mix_gain,dig_gain for specify rf_power to achieve this purpose. This is not recommended, because this might break the regulator for specific country.
38 38  
39 -Please note, that the global_conf.json file will be overwritten by the match region files in /etc/lora/cfg-30x when changing settings on the web. So the user needs to change the files in /etc/lora/cfg-cfg-30x instead of global_conf.json
40 -
41 -
42 -= Change Power for LoRaWAN Basic Station connection =
43 -
44 -----
45 -
46 -When users use LoRaWAN Basic Station, How to Change the Power for the LoRaWAN Basic Station connection?
47 -
48 -If users want to always use a higher power or a lower power. Users can modify the pa_gain,mix_gain, and dig_gain to specify rf_power to achieve this purpose. This is not recommended, because this might break the regulator for a specific country.
49 -
50 -
34 +Please note, that the global_conf.json file will be overwritten by the match region files in /etc/lora/cfg-30x when changing settings in the web. So user needs to change the files in /etc/lora/cfg-cfg-30x instead of global_conf.json
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0