1 -= Introduction =
1 += Overview: =
2 2  
3 +In LoRaWAN protocol, the gateway transmit packet uses the output power base on the Power Index from the LoRaWAN server downlink. for example, the LoRaWAN server sends a downlink with this info "rf_power=14", gateway got this info and it will search the index for rf_power=14 and use the related rf setting to set output power. In some cases, the LoRaWAN server might set the rf-power to a quite low value ( for example 0dB) which is not practical for use. In such a case, the User can manually change the rf_power=0's rf settings to a higher power out. Below are the methods.
4 +
5 +
6 += Change Power for Semtech UDP Paket forward connection =
7 +
3 3  ----
4 4  
5 -In LoRaWAN protocol, the gateway output power refer to the downstream packets sent by Gateway. This output power is controlled by LoRaWAN server.
10 +In LoRaWAN protocol, the gateway output power refers to the downstream packets sent by Gateway. This output power is controlled by the LoRaWAN server.
6 6  
7 -Gateway maintain a power index in the file: /etc/lora/global_conf.json for example:
12 +Gateway maintains a power index in the file: /etc/lora/global_conf.json for example:
8 8  
9 9  
10 10  (% class="box" %)
... ... @@ -24,11 +24,22 @@
24 24   "dig_gain": 0
25 25  )))
26 26  
27 -(% class="mark" %)Note: If when lorawan server specify a rf_power which is not list above. gateway will choose the closest power. profile.
32 +(% class="mark" %)Note: If when lorawan server specifies a rf_power that is not listed above. gateway will choose the closest power. profile.
28 28  
29 29  
30 -When LoRaWAN server sends a downlink stream, server will also ask the gateway to use which rf_power as output. So user don't need to consider to control in the gateway side.
35 +When the LoRaWAN server sends a downlink stream, the server will also ask the gateway to use rf_power as output. So users don't need to consider controlling on the gateway side.
31 31  
32 -If user want to always use a higher power or a lower power. User can modify the pa_gain,mix_gain,dig_gain for specify rf_power to achieve this purpose. This is not recommended, because this might break the regulator for specific country.
37 +If users want to always use a higher power or a lower power. Users can modify the pa_gain,mix_gain, and dig_gain to specify rf_power to achieve this purpose. This is not recommended, because this might break the regulator for a specific country.
33 33  
34 -Please note, that the global_conf.json file will be overwritten by the match region files in /etc/lora/cfg-30x when changing settings in the web. So user needs to change the files in /etc/lora/cfg-cfg-30x instead of global_conf.json
39 +Please note, that the global_conf.json file will be overwritten by the match region files in /etc/lora/cfg-30x when changing settings on the web. So the user needs to change the files in /etc/lora/cfg-cfg-30x instead of global_conf.json
40 +
41 +
42 += Change Power for LoRaWAN Basic Station connection =
43 +
44 +----
45 +
46 +When users use LoRaWAN Basic Station, How to Change the Power for the LoRaWAN Basic Station connection?