1 | **Table of Contents:** | ||
2 | |||
3 | {{toc/}} | ||
4 | |||
5 | |||
6 | = 1. WSS-09 9 in 1 Weather Station Sensor = | ||
7 | |||
8 | == 1.1 Overview and Spec == | ||
9 | |||
10 | Older versions of interfaces New version of the interface | ||
11 | |||
12 | [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/WSC2-LB_LoRaWAN_Weather_Station_User_Manual/WebHome/image-20240708092247-1.png?rev=1.1||alt="image-20240708092247-1.png"]] [[image:image-20250505190747-1.png||height="275" width="220"]] | ||
13 | |||
14 | **Power Input**: 10 ~~ 30VDC | ||
15 | |||
16 | **Max Power Consumption**: 1.2W | ||
17 | |||
18 | **Wind Speed:** | ||
19 | |||
20 | * Range: 0~~60m/s | ||
21 | * Accuracy: ±(0.2m/s±0.02*v)(v : the wind speed) | ||
22 | * Ultrasonic measurement,no start wind strength needed | ||
23 | |||
24 | **Wind Direction:** | ||
25 | |||
26 | * Range: 0~~3599 | ||
27 | * Accuracy: ±3° | ||
28 | * Ultrasonic measurement,no start wind strength needed | ||
29 | * Built-in electronic compass. No need to consider installation direction | ||
30 | |||
31 | **Temperature:** | ||
32 | |||
33 | * Range: -40°C ~~ +80°C | ||
34 | * Accuracy: ±0.5°C | ||
35 | |||
36 | **Humidity:** | ||
37 | |||
38 | * Range: 0 ~~ 99% RH | ||
39 | * Accuracy Tolerance : Typ ±3% RH | ||
40 | |||
41 | **Air Pressure:** | ||
42 | |||
43 | * Accuracy: ±0.15kPa@25°C 101kPa | ||
44 | * Range: 0~~120kPa | ||
45 | |||
46 | **Noise:** | ||
47 | |||
48 | * Range: 30dB~~120dB | ||
49 | * Accuracy: ±0.5dB | ||
50 | |||
51 | **PM2.5:** | ||
52 | |||
53 | * Range: 0~~1000ug/m3 | ||
54 | * Accuracy: ±3%FS | ||
55 | * Resolution: 1ug/m3 | ||
56 | |||
57 | **PM10:** | ||
58 | |||
59 | * Range: 0~~1000ug/m3 | ||
60 | * Accuracy: ±3%FS | ||
61 | * Resolution: 1ug/m3 | ||
62 | |||
63 | **llumination:** | ||
64 | |||
65 | * Range: 0~~200k Lux | ||
66 | * Accuracy: ±7%(25 °C) | ||
67 | |||
68 | == 1.2 Wiring == | ||
69 | |||
70 | === 1.2.1 Older version wiring === | ||
71 | |||
72 | [[image:image-20240714104450-1.png||height="239" width="445"]] | ||
73 | |||
74 | |||
75 | === 1.2.2 New version wiring === | ||
76 | |||
77 | [[image:image-20250505193603-10.png||height="405" width="762"]] | ||
78 | |||
79 | |||
80 | == 1.3 Mechinical Drawing == | ||
81 | |||
82 | |||
83 | (% class="lead" %) | ||
84 | **Device Dimension** | ||
85 | |||
86 | [[image:image-20240714165651-5.png||height="308" width="245"]] | ||
87 | |||
88 | |||
89 | (% class="lead" %) | ||
90 | **Installation** | ||
91 | |||
92 | * Make sure the device is horizontal installed | ||
93 | * Device include electronic compass. No need to consider installation direction to get correct wind direction. | ||
94 | |||
95 | = 2. WSS-08 Optical Range Guage = | ||
96 | |||
97 | == 2.1 Overview and Spec == | ||
98 | |||
99 | |||
100 | Older versions of interfaces New version of the interface | ||
101 | |||
102 | [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/WSC2-LB_LoRaWAN_Weather_Station_User_Manual/WebHome/image-20240707215336-2.png?width=218&height=159&rev=1.1||alt="image-20240707215336-2.png" height="159" width="218"]] [[image:image-20250505190822-2.png||height="155" width="197"]] | ||
103 | |||
104 | * Input Power: 9~~30 VDC | ||
105 | * Sense diameter: 6cm | ||
106 | * Pulse Output, each pulse , 0.1mm | ||
107 | * Max rain: 24mm/min | ||
108 | * Operation Temperature: -40 ~~ 60 °C | ||
109 | * Operation Humidify: 0~~99%RH(no dew) | ||
110 | |||
111 | == 2.2 Wiring == | ||
112 | |||
113 | === 2.2.1 Older version wiring === | ||
114 | |||
115 | [[image:image-20241127091433-1.jpeg||height="361" width="517"]] | ||
116 | |||
117 | |||
118 | === 2.2.2 New version wiring === | ||
119 | |||
120 | |||
121 | [[image:image-20250505193511-9.png||height="392" width="708"]] | ||
122 | |||
123 | == 2.3 Mechinical Drawing == | ||
124 | |||
125 | |||
126 | (% class="lead" %) | ||
127 | **Device Dimension** | ||
128 | |||
129 | [[image:image-20240714164433-1.png||height="211" width="548"]] | ||
130 | |||
131 | |||
132 | (% class="lead" %) | ||
133 | **Bracket Dimension** | ||
134 | |||
135 | [[image:image-20240714164803-3.png||height="306" width="836"]] | ||
136 | |||
137 | |||
138 | (% class="lead" %) | ||
139 | **Install without Bracket** | ||
140 | |||
141 | [[image:image-20240714164856-4.png||height="250" width="433"]] | ||
142 | |||
143 | |||
144 | = 3. WSS-27 Photosynthetically Active Radiation Sensor = | ||
145 | |||
146 | == 3.1 Overview and Spec == | ||
147 | |||
148 | [[image:1746411474621-748.png||height="175" width="224"]] | ||
149 | |||
150 | * Input Power: 5~~24V DC | ||
151 | * Measuring range: 0~~2500μmol/m2·s | ||
152 | * Response time: <1S | ||
153 | * Resolution: 1μmol/m2·s | ||
154 | * Accuracy: ±2% | ||
155 | * Response spectrum: 400~~700nm | ||
156 | * Output signal: RS485 (standard Modbus-RTU protocol) | ||
157 | * Stability: change within one year ≤±2% | ||
158 | * Working environment: -30℃~~75℃ | ||
159 | |||
160 | == 3.2 Wiring == | ||
161 | |||
162 | [[image:image-20250505193330-8.png||height="393" width="744"]] | ||
163 | |||
164 | == 3.3 Device Dimension == | ||
165 | |||
166 | [[image:1746424326901-763.png]] | ||
167 | |||
168 | |||
169 | = 4. WSS-26 Simple Total Radiation Sensor = | ||
170 | |||
171 | == 4.1 Overview and Spec == | ||
172 | |||
173 | [[image:1746423871465-411.png||height="217" width="278"]] | ||
174 | |||
175 | * (% id="cke_bm_101984S" style="display:none" %) (%%)Input Power: 5~~24V DC | ||
176 | * Spectral Range: 0.3~~3μm (300~~3000nm) | ||
177 | * Measuring Range: 0~~2000W/m^^2^^ | ||
178 | * Resolution: 0.1W/m^^2^^ | ||
179 | * Measurement Accuracy: ±3% | ||
180 | * Output signal: RS485 (standard Modbus-RTU protocol) | ||
181 | * Temperature Characteristics: ±2% (-10℃~~40℃) | ||
182 | * Response Time: <1s | ||
183 | * Annual Stability: ≤±2% | ||
184 | * Cosine Response: ≤7% (When the sun altitude angle is 10°) | ||
185 | * Azimuth Response Error: ≤5% (When the sun altitude angle is 10°) | ||
186 | * Working environment: -40℃~~70℃ | ||
187 | |||
188 | == 4.2 Wiring == | ||
189 | |||
190 | |||
191 | [[image:image-20250505193313-7.png||height="391" width="722"]] | ||
192 | |||
193 | == 4.3 Device Dimension == | ||
194 | |||
195 | [[image:1746424326901-763.png]] | ||
196 | |||
197 | |||
198 | = 5. WSS-25 Air Temperature and Humidity = | ||
199 | |||
200 | == 5.1 Overview and Spec == | ||
201 | |||
202 | [[image:1746424465810-974.png||height="325" width="288"]] | ||
203 | |||
204 | |||
205 | * Supply voltage: 5~~24V DC | ||
206 | * Temperature Measuring Range: Standard -30~~70℃ or 0~~50℃ | ||
207 | * Humidity Measuring Range: 0~~100%RH(Non-condensing state) | ||
208 | * Accuracy: ±0.2℃ (@25℃); ±3%RH (10%~~90%) | ||
209 | * Repeatability: ±0.1℃; ±0.1%RH | ||
210 | * Long-term stability: <0.04℃/year; <0.5%RH/year | ||
211 | * Output signal:RS485 (standard Modbus-RTU protocol) | ||
212 | * Response time: <1s | ||
213 | * Working Environment: Temperature: -55℃~~120℃; Humidity: ≤95%RH | ||
214 | |||
215 | == 5.2 Wiring == | ||
216 | |||
217 | |||
218 | [[image:image-20250505193252-6.png||height="409" width="765"]] | ||
219 | |||
220 | == 5.3 Device Dimension == | ||
221 | |||
222 | |||
223 | [[image:1746425244897-496.png||height="363" width="684"]] | ||
224 | |||
225 | |||
226 | = 6. WSS-24 Rain and snow sensor = | ||
227 | |||
228 | == 6.1 Overview and Spec == | ||
229 | |||
230 | [[image:image-20250505140953-12.png||height="293" width="246"]] | ||
231 | |||
232 | |||
233 | * Supply voltage: 12~~24V DC | ||
234 | * Measurement parameters: Rain or snow | ||
235 | * Working temperature: -30~~70℃; humidity: 10~~90%RH | ||
236 | * Storage temperature: -40~80℃; humidity: 10~~90%RH | ||
237 | * Output signal: RS485 (standard Modbus-RTU protocol) | ||
238 | * Stability and response time: <1 second | ||
239 | |||
240 | == 6.2 Wiring == | ||
241 | |||
242 | [[image:image-20250505193053-5.png]] | ||
243 | |||
244 | == 6.3 Device Dimension == | ||
245 | |||
246 | [[image:image-20250505144906-15.png]] | ||
247 | |||
248 | |||
249 | == 6.4 Installation Angle Requirements == | ||
250 | |||
251 | |||
252 | During installation, the sensor sensing surface should be kept at a 15-degree angle to the horizontal plane to prevent rain and snow accumulation from affecting sensor measurement. | ||
253 | |||
254 | [[image:image-20250505190308-23.png]] | ||
255 | |||
256 | |||
257 | = 7. WSS-23 CO2 Sensor & PM2.5 & PM10 Sensor = | ||
258 | |||
259 | == 7.1 Overview and Spec == | ||
260 | |||
261 | [[image:1746427977346-600.png||height="261" width="318"]] | ||
262 | |||
263 | |||
264 | * Supply voltage: 7~~24V DC | ||
265 | * Average current: Peak value ≤200mA; average 85 mA | ||
266 | * Warm-up time: 3min | ||
267 | * Response time: <90s | ||
268 | * Stability: ≤2% F•S | ||
269 | |||
270 | **CO2 Sensor:** | ||
271 | |||
272 | |||
273 | * Measurement parameters: Carbon dioxide concentration | ||
274 | * Measurement range: 0~~2000ppm, 0~~5000ppm, 0~~10000ppm | ||
275 | * Accuracy: ±3%F•S (25℃) | ||
276 | * Resolution: 1ppm | ||
277 | * Output signal: RS485 (standard Modbus-RTU protocol) | ||
278 | * Working temperature: 0℃~~50℃ | ||
279 | * Working humidity: 0~~95%RH | ||
280 | |||
281 | **PM2.5 & PM10 Sensor** | ||
282 | |||
283 | * Measurement parameters: PM2.5 & PM10 concentration | ||
284 | * Detection range: 0~~1000μg/m3 | ||
285 | * Resolution: 1μg/m3 | ||
286 | * Accuracy: ±3%F•S (25℃) | ||
287 | * Working temperature: -30℃~~50℃ | ||
288 | * Storage temperature: -40℃~~60℃ | ||
289 | * Working humidity: 15~~80%RH (no condensation) | ||
290 | * Temperature drift: 0.2%F•S/℃ | ||
291 | * Average current: 50mA@7V; 35mA@12V; 20mA@24V | ||
292 | * Stability: ≤2%F•S | ||
293 | * Warm-up time: 3min | ||
294 | * Response time: <90s | ||
295 | |||
296 | == 7.2 Wiring == | ||
297 | |||
298 | [[image:image-20250505193033-4.png||height="376" width="689"]] | ||
299 | |||
300 | == 7.3 Device Dimension == | ||
301 | |||
302 | |||
303 | [[image:1746440854349-915.png||height="312" width="588"]] | ||
304 | |||
305 | |||
306 | = 8. WSS-22 Integrated wind speed and direction sensor = | ||
307 | |||
308 | == 8.1 Overview and Spec == | ||
309 | |||
310 | [[image:1746441120854-584.png||height="271" width="394"]] | ||
311 | |||
312 | * Supply voltage: 5~~24V DC | ||
313 | * Wind speed measurement range: 0~~30m/s; 0~~50m/s; 0~~60m/s; | ||
314 | * Wind direction measurement range: 0~~360° | ||
315 | * Starting wind speed: ≤0.3m/s | ||
316 | * Accuracy: ±(0.3+0.03V) m/s, ±1° | ||
317 | * Output signal: RS485 (standard Modbus-RTU protocol) | ||
318 | * Working environment: Temperature: -30℃~~70℃; Humidity: ≤100%RH | ||
319 | * Storage environment: Temperature: -30℃~~70℃; Humidity: ≤100%RH | ||
320 | |||
321 | == 8.2 Wiring == | ||
322 | |||
323 | [[image:image-20250505192929-2.png||height="314" width="590"]] | ||
324 | |||
325 | |||
326 | == 8.3 Device Dimension == | ||
327 | |||
328 | [[image:1746441469178-155.png||height="372" width="405"]] | ||
329 | |||
330 | [[image:1746441481289-965.png||height="370" width="404"]] | ||
331 | |||
332 | |||
333 | == 8.4 Installation method == | ||
334 | |||
335 | |||
336 | **The integrated wind speed and direction sensor (the outlet is pointing south, the opposite direction is north), the installation method is as follows:** | ||
337 | |||
338 | [[image:1746441560175-162.png||height="304" width="484"]] | ||
339 | |||
340 | |||
341 | = 9. WSS-21 Rain Sensor = | ||
342 | |||
343 | == 9.1 Overview and Spec == | ||
344 | |||
345 | [[image:image-20250505184214-19.png||height="324" width="320"]] | ||
346 | |||
347 | |||
348 | * Rain-receiving port size: Φ200mm; sharp angle of blade: 40°~~45° | ||
349 | * Range: 0~~100mm (range is limited to analog signal, RS485 signal is not measured) | ||
350 | * Resolution: 0.2mm | ||
351 | * Rain intensity range: 0mm~~4mm/min (maximum rain intensity allowed is 8mm/min) | ||
352 | * Accuracy: ≤±3% | ||
353 | * Output signal: RS485 (standard Modbus-RTU protocol) | ||
354 | * Power supply voltage: 5~~24V DC | ||
355 | * Operating temperature: 0℃~~70℃ (optional heating function, can be as low as -40℃) | ||
356 | * Operating humidity: <100% (no condensation) | ||
357 | |||
358 | == 9.2 Wiring == | ||
359 | |||
360 | [[image:image-20250505192952-3.png||height="305" width="581"]] | ||
361 | |||
362 | |||
363 | == 9.3 Device Dimension == | ||
364 | |||