Wiki source code of Agriculture & Weather Stations
Version 58.1 by Mengting Qiu on 2025/05/05 19:32
Show last authors
author | version | line-number | content |
---|---|---|---|
1 | **Table of Contents:** | ||
2 | |||
3 | {{toc/}} | ||
4 | |||
5 | |||
6 | = 1. WSS-09 9 in 1 Weather Station Sensor = | ||
7 | |||
8 | == 1.1 Overview and Spec == | ||
9 | |||
10 | Older versions of interfaces New version of the interface | ||
11 | |||
12 | [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/WSC2-LB_LoRaWAN_Weather_Station_User_Manual/WebHome/image-20240708092247-1.png?rev=1.1||alt="image-20240708092247-1.png"]] [[image:image-20250505190747-1.png||height="275" width="220"]] | ||
13 | |||
14 | **Power Input**: 10 ~~ 30VDC | ||
15 | |||
16 | **Max Power Consumption**: 1.2W | ||
17 | |||
18 | **Wind Speed:** | ||
19 | |||
20 | * Range: 0~~60m/s | ||
21 | * Accuracy: ±(0.2m/s±0.02*v)(v : the wind speed) | ||
22 | * Ultrasonic measurement,no start wind strength needed | ||
23 | |||
24 | **Wind Direction:** | ||
25 | |||
26 | * Range: 0~~3599 | ||
27 | * Accuracy: +3° | ||
28 | * Ultrasonic measurement,no start wind strength needed | ||
29 | * Built-in electronic compass. No need to consider installation direction | ||
30 | |||
31 | **Temperature:** | ||
32 | |||
33 | * Range: -40°C ~~ +80°C | ||
34 | * Accuracy: +0.5°C | ||
35 | |||
36 | **Humidity:** | ||
37 | |||
38 | * Range: 0 ~~ 99% RH | ||
39 | * Accuracy Tolerance : Typ +3% RH | ||
40 | |||
41 | **Air Pressure:** | ||
42 | |||
43 | * Accuracy: ±0.15kPa@25°C 101kPa | ||
44 | * Range: 0~~120kPa | ||
45 | |||
46 | **Noise:** | ||
47 | |||
48 | * Range: 30dB~~120dB | ||
49 | * Accuracy: +0.5dB | ||
50 | |||
51 | **PM2.5:** | ||
52 | |||
53 | * Range: 0~~1000ug/m3 | ||
54 | * Accuracy: ±3%FS | ||
55 | * Resolution: 1ug/m3 | ||
56 | |||
57 | **PM10:** | ||
58 | |||
59 | * Range: 0~~1000ug/m3 | ||
60 | * Accuracy: +3%FS | ||
61 | * Resolution: 1ug/m3 | ||
62 | |||
63 | **llumination:** | ||
64 | |||
65 | * Range: 0~~200k Lux | ||
66 | * Accuracy: +7%(25 °C) | ||
67 | |||
68 | == 1.2 Wiring == | ||
69 | |||
70 | === 1.2.1 Older version wiring === | ||
71 | |||
72 | [[image:image-20240714104450-1.png||height="239" width="445"]] | ||
73 | |||
74 | |||
75 | === 1.2.2 New version wiring === | ||
76 | |||
77 | [[image:image-20250505102835-7.png||height="409" width="739"]] | ||
78 | |||
79 | |||
80 | |||
81 | == 1.3 Mechinical Drawing == | ||
82 | |||
83 | (% class="lead" %) | ||
84 | **Device Dimension** | ||
85 | |||
86 | [[image:image-20240714165651-5.png||height="308" width="245"]] | ||
87 | |||
88 | |||
89 | (% class="lead" %) | ||
90 | **Installation** | ||
91 | |||
92 | * Make sure the device is horizontal installed | ||
93 | * Device include electronic compass. No need to consider installation direction to get correct wind direction. | ||
94 | |||
95 | = 2. WSS-08 Optical Range Guage = | ||
96 | |||
97 | == 2.1 Overview and Spec == | ||
98 | |||
99 | Older versions of interfaces New version of the interface | ||
100 | |||
101 | [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/WSC2-LB_LoRaWAN_Weather_Station_User_Manual/WebHome/image-20240707215336-2.png?width=218&height=159&rev=1.1||alt="image-20240707215336-2.png" height="159" width="218"]] [[image:image-20250505190822-2.png||height="155" width="197"]] | ||
102 | |||
103 | * Input Power: 9~~30 VDC | ||
104 | * Sense diameter: 6cm | ||
105 | * Pulse Output, each pulse , 0.1mm | ||
106 | * Max rain: 24mm/min | ||
107 | * Operation Temperature: -40 ~~ 60 °C | ||
108 | * Operation Humidify: 0~~99%RH(no dew) | ||
109 | |||
110 | == 2.2 Wiring == | ||
111 | |||
112 | === 2.2.1 Older version wiring === | ||
113 | |||
114 | [[image:image-20241127091433-1.jpeg||height="361" width="517"]] | ||
115 | |||
116 | === 2.2.2 New version wiring === | ||
117 | |||
118 | [[image:image-20250505101405-5.png||height="381" width="748"]] | ||
119 | |||
120 | |||
121 | == 2.3 Mechinical Drawing == | ||
122 | |||
123 | (% class="lead" %) | ||
124 | **Device Dimension** | ||
125 | |||
126 | [[image:image-20240714164433-1.png||height="211" width="548"]] | ||
127 | |||
128 | |||
129 | (% class="lead" %) | ||
130 | **Bracket Dimension** | ||
131 | |||
132 | [[image:image-20240714164803-3.png||height="306" width="836"]] | ||
133 | |||
134 | |||
135 | (% class="lead" %) | ||
136 | **Install without Bracket** | ||
137 | |||
138 | [[image:image-20240714164856-4.png||height="250" width="433"]] | ||
139 | |||
140 | |||
141 | |||
142 | = 3. WSS-27 Photosynthetically Active Radiation Sensor = | ||
143 | |||
144 | == 3.1 Overview and Spec == | ||
145 | |||
146 | [[image:1746411474621-748.png||height="175" width="224"]] | ||
147 | |||
148 | * Input Power: 5~~24V DC | ||
149 | * Measuring range: 0~2500μmol/m2·s | ||
150 | * Response time: <1S | ||
151 | * Resolution: 1μmol/m2·s | ||
152 | * Accuracy: ±2% | ||
153 | * Response spectrum: 400~700nm | ||
154 | * Output signal: RS485 (standard Modbus-RTU protocol) | ||
155 | * Stability: change within one year <±2% | ||
156 | * Working environment: -30℃~75℃ | ||
157 | |||
158 | == 3.2 Wiring == | ||
159 | |||
160 | |||
161 | [[image:image-20250505102905-9.png||height="406" width="771"]] | ||
162 | |||
163 | == 3.3 Device Dimension == | ||
164 | |||
165 | [[image:1746424326901-763.png]] | ||
166 | |||
167 | |||
168 | |||
169 | = 4. WSS-06 Simple Total Radiation Sensor = | ||
170 | |||
171 | == 4.1 Overview and Spec == | ||
172 | |||
173 | [[image:1746423871465-411.png||height="217" width="278"]] | ||
174 | |||
175 | * (% id="cke_bm_101984S" style="display:none" %) (%%)Input Power: 5~~24V DC | ||
176 | * Spectral Range: 0.3~3μm (300~3000nm) | ||
177 | * Measuring Range: 0~2000W/m^^2^^ | ||
178 | * Resolution: 0.1W/m^^2^^ | ||
179 | * Measurement Accuracy: ±3% | ||
180 | * Output signal: RS485 (standard Modbus-RTU protocol) | ||
181 | * Temperature Characteristics: ±2% (-10℃~40℃) | ||
182 | * Response Time: <1s | ||
183 | * Annual Stability: ≤±2% | ||
184 | * Cosine Response: ≤7% (When the sun altitude angle is 10°) | ||
185 | * Azimuth Response Error: ≤5% (When the sun altitude angle is 10°) | ||
186 | * Working environment: -40℃~70℃ | ||
187 | |||
188 | == 4.2 Wiring == | ||
189 | |||
190 | |||
191 | [[image:image-20250505140615-10.png||height="419" width="791"]] | ||
192 | |||
193 | == 4.3 Device Dimension == | ||
194 | |||
195 | [[image:1746424326901-763.png]] | ||
196 | |||
197 | |||
198 | |||
199 | = 5. WSS-25 Air Temperature and Humidity = | ||
200 | |||
201 | == 5.1 Overview and Spec == | ||
202 | |||
203 | [[image:1746424465810-974.png||height="325" width="288"]] | ||
204 | |||
205 | |||
206 | * Supply voltage: 5~~24V DC | ||
207 | * Temperature Measuring Range: Standard -30~~70℃ or 0~~50℃ | ||
208 | * Humidity Measuring Range: 0~100%RH(Non-condensing state) | ||
209 | * Accuracy: ±0.2℃ (@25℃); ±3%RH (10%~90%) | ||
210 | * Repeatability: ±0.1℃; ±0.1%RH | ||
211 | * Long-term stability: <0.04℃/year; <0.5%RH/year | ||
212 | * Output signal:RS485 (standard Modbus-RTU protocol) | ||
213 | * Response time: <1s | ||
214 | * Working Environment: Temperature: -55℃~120℃; Humidity: ≤95%RH | ||
215 | |||
216 | == 5.2 Wiring == | ||
217 | |||
218 | |||
219 | [[image:image-20250505140636-11.png||height="419" width="794"]] | ||
220 | |||
221 | == 5.3 Device Dimension == | ||
222 | |||
223 | |||
224 | [[image:1746425244897-496.png||height="363" width="684"]] | ||
225 | |||
226 | |||
227 | = 6. WSS-24 Rain and snow sensor = | ||
228 | |||
229 | == 6.1 Overview and Spec == | ||
230 | |||
231 | [[image:image-20250505140953-12.png||height="293" width="246"]] | ||
232 | |||
233 | |||
234 | * Supply voltage: 12~~24V DC | ||
235 | * Measurement parameters: Rain or snow | ||
236 | * Working temperature: -30~70℃; humidity: 10~90%RH | ||
237 | * Storage temperature: -40~80℃; humidity: 10~90%RH | ||
238 | * Output signal: RS485 (standard Modbus-RTU protocol) | ||
239 | * Stability and response time: <1 second | ||
240 | |||
241 | == 6.2 Wiring == | ||
242 | |||
243 | |||
244 | [[image:image-20250505144810-14.png]] | ||
245 | |||
246 | == 6.3 Device Dimension == | ||
247 | |||
248 | [[image:image-20250505144906-15.png]] | ||
249 | |||
250 | |||
251 | == 6.4 Installation Angle Requirements == | ||
252 | |||
253 | During installation, the sensor sensing surface should be kept at a 15-degree angle to the horizontal plane to prevent rain and snow accumulation from affecting sensor measurement. | ||
254 | |||
255 | [[image:image-20250505190308-23.png]] | ||
256 | |||
257 | |||
258 | = 7. WSS-23 CO2 Sensor & PM2.5 & PM10 Sensor = | ||
259 | |||
260 | == 7.1 Overview and Spec == | ||
261 | |||
262 | [[image:1746427977346-600.png||height="261" width="318"]] | ||
263 | |||
264 | |||
265 | * Supply voltage: 7~~24V DC | ||
266 | * Average current: Peak value ≤200mA; average 85 mA | ||
267 | * Warm-up time: 3min | ||
268 | * Response time: <90s | ||
269 | * Stability: ≤2% F•S | ||
270 | |||
271 | **CO2 Sensor:** | ||
272 | |||
273 | |||
274 | * Measurement parameters: Carbon dioxide concentration | ||
275 | * Measurement range: 0-2000ppm, 0-5000ppm, 0-10000ppm | ||
276 | * Accuracy: ±3%F•S (25℃) | ||
277 | * Resolution: 1ppm | ||
278 | * Output signal: RS485 (standard Modbus-RTU protocol) | ||
279 | * Working temperature: 0℃~50℃ | ||
280 | * Working humidity: 0~95%RH | ||
281 | |||
282 | **PM2.5 & PM10 Sensor** | ||
283 | |||
284 | * Measurement parameters: PM2.5 & PM10 concentration | ||
285 | * Detection range: 0-1000μg/m3 | ||
286 | * Resolution: 1μg/m3 | ||
287 | * Accuracy: ±3%F•S (25℃) | ||
288 | * Working temperature: -30℃~50℃ | ||
289 | * Storage temperature: -40℃~60℃ | ||
290 | * Working humidity: 15~80%RH (no condensation) | ||
291 | * Temperature drift: 0.2%F•S/℃ | ||
292 | * Average current: 50mA@7V; 35mA@12V; 20mA@24V | ||
293 | * Stability: ≤2%F•S | ||
294 | * Warm-up time: 3min | ||
295 | * Response time: <90s | ||
296 | |||
297 | == 7.2 Wiring == | ||
298 | |||
299 | [[image:image-20250505182902-17.png||height="372" width="698"]] | ||
300 | |||
301 | == 7.3 Device Dimension == | ||
302 | |||
303 | |||
304 | [[image:1746440854349-915.png||height="312" width="588"]] | ||
305 | |||
306 | |||
307 | |||
308 | |||
309 | = 8. WSS-22 Integrated wind speed and direction sensor = | ||
310 | |||
311 | == 8.1 Overview and Spec == | ||
312 | |||
313 | [[image:1746441120854-584.png||height="271" width="394"]] | ||
314 | |||
315 | * Supply voltage: 5~~24V DC | ||
316 | * Wind speed measurement range: 0~30m/s; 0~50m/s; 0~60m/s; | ||
317 | * Wind direction measurement range: 0~360° | ||
318 | * Starting wind speed: ≤0.3m/s | ||
319 | * Accuracy: ±(0.3+0.03V) m/s, ±1° | ||
320 | * Output signal: RS485 (standard Modbus-RTU protocol) | ||
321 | * Working environment: Temperature: -30℃~70℃; Humidity: ≤100%RH | ||
322 | * Storage environment: Temperature: -30℃~70℃; Humidity: ≤100%RH | ||
323 | |||
324 | == 8.2 Wiring == | ||
325 | |||
326 | [[image:image-20250505183552-18.png||height="288" width="550"]] | ||
327 | |||
328 | |||
329 | == 8.3 Device Dimension == | ||
330 | |||
331 | [[image:1746441469178-155.png||height="372" width="405"]] | ||
332 | |||
333 | [[image:1746441481289-965.png||height="370" width="404"]] | ||
334 | |||
335 | |||
336 | == 8.4 Installation method == | ||
337 | |||
338 | **The integrated wind speed and direction sensor (the outlet is pointing south, the opposite direction is north), the installation method is as follows:** | ||
339 | |||
340 | [[image:1746441560175-162.png||height="304" width="484"]] | ||
341 | |||
342 | |||
343 | |||
344 | = 9. WSS-21 Rain Sensor = | ||
345 | |||
346 | == 9.1 Overview and Spec == | ||
347 | |||
348 | [[image:image-20250505184214-19.png||height="324" width="320"]] | ||
349 | |||
350 | |||
351 | * Rain-receiving port size: Φ200mm; sharp angle of blade: 40°~45° | ||
352 | * Range: 0~100mm (range is limited to analog signal, RS485 signal is not measured) | ||
353 | * Resolution: 0.2mm | ||
354 | * Rain intensity range: 0mm~4mm/min (maximum rain intensity allowed is 8mm/min) | ||
355 | * Accuracy: ≤±3% | ||
356 | * Output signal: RS485 (standard Modbus-RTU protocol) | ||
357 | * Power supply voltage: 5~24V DC | ||
358 | * Operating temperature: 0℃~70℃ (optional heating function, can be as low as -40℃) | ||
359 | * Operating humidity: <100% (no condensation) | ||
360 | |||
361 | == 9.2 Wiring == | ||
362 | |||
363 | [[image:image-20250505184559-21.png||height="335" width="631"]] | ||
364 | |||
365 | |||
366 | == 9.3 Device Dimension == | ||
367 | |||
368 | |||
369 | [[image:image-20250505184528-20.png||height="468" width="471"]] | ||
370 | |||