Agriculture & Weather Stations
Version 45.1 by Mengting Qiu on 2025/05/05 18:53
Table of Contents:
- 1. WSS-09 9 in 1 Weather Station Sensor
- 2. WSS-08 Optical Range Guage
- 3. WSS-27 Photosynthetically Active Radiation Sensor
- 4. WSS-06 Simple Total Radiation Sensor
- 5. WSS-25 Air Temperature and Humidity
- 6. WSS-24 Rain and snow sensor
- 7. Carbon dioxide sensor
1. WSS-09 9 in 1 Weather Station Sensor
1.1 Overview and Spec
Power Input: 10 ~ 30VDC
Max Power Consumption: 1.2W
Wind Speed:
- Range: 0~60m/s
- Accuracy: ±(0.2m/s±0.02*v)(v : the wind speed)
- Ultrasonic measurement,no start wind strength needed
Wind Direction:
- Range: 0~3599
- Accuracy: +3°
- Ultrasonic measurement,no start wind strength needed
- Built-in electronic compass. No need to consider installation direction
Temperature:
- Range: -40°C ~ +80°C
- Accuracy: +0.5°C
Humidity:
- Range: 0 ~ 99% RH
- Accuracy Tolerance : Typ +3% RH
Air Pressure:
- Accuracy: ±0.15kPa@25°C 101kPa
- Range: 0~120kPa
Noise:
- Range: 30dB~120dB
- Accuracy: +0.5dB
PM2.5:
- Range: 0~1000ug/m3
- Accuracy: ±3%FS
- Resolution: 1ug/m3
PM10:
- Range: 0~1000ug/m3
- Accuracy: +3%FS
- Resolution: 1ug/m3
llumination:
- Range: 0~200k Lux
- Accuracy: +7%(25 °C)
1.2 Wiring
1.2.1 Older version wiring
1.2.2 New version wiring
1.3 Mechinical Drawing
Device Dimension
Installation
- Make sure the device is horizontal installed
- Device include electronic compass. No need to consider installation direction to get correct wind direction.
2. WSS-08 Optical Range Guage
2.1 Overview and Spec
- Input Power: 9~30 VDC
- Sense diameter: 6cm
- Pulse Output, each pulse , 0.1mm
- Max rain: 24mm/min
- Operation Temperature: -40 ~ 60 °C
- Operation Humidify: 0~99%RH(no dew)
2.2 Wiring
2.2.1 Older version wiring
2.2.2 New version wiring
2.3 Mechinical Drawing
Device Dimension
Bracket Dimension
Install without Bracket
3. WSS-27 Photosynthetically Active Radiation Sensor
3.1 Overview and Spec
- Input Power: 5~24V DC
- Measuring range: 0~2500μmol/m2·s
- Response time: <1S
- Resolution: 1μmol/m2·s
- Accuracy: ±2%
- Response spectrum: 400~700nm
- Output signal: RS485 (standard Modbus-RTU protocol)
- Stability: change within one year <±2%
- Working environment: -30℃~75℃
3.2 Wiring
3.3 Mechinical Drawing
4. WSS-06 Simple Total Radiation Sensor
4.1 Overview and Spec
- Input Power: 5~24V DC
- Spectral Range: 0.3~3μm (300~3000nm)
- Measuring Range: 0~2000W/m2
- Resolution: 0.1W/m2
- Measurement Accuracy: ±3%
- Output signal: RS485 (standard Modbus-RTU protocol)
- Temperature Characteristics: ±2% (-10℃~40℃)
- Response Time: <1s
- Annual Stability: ≤±2%
- Cosine Response: ≤7% (When the sun altitude angle is 10°)
- Azimuth Response Error: ≤5% (When the sun altitude angle is 10°)
- Working environment: -40℃~70℃
4.2 Wiring
4.3 Mechinical Drawing
5. WSS-25 Air Temperature and Humidity
5.1 Overview and Spec
- Supply voltage: 5~24V DC
- Temperature Measuring Range: Standard -30~70℃ or 0~50℃
- Humidity Measuring Range: 0~100%RH(Non-condensing state)
- Accuracy: ±0.2℃ (@25℃); ±3%RH (10%~90%)
- Repeatability: ±0.1℃; ±0.1%RH
- Long-term stability: <0.04℃/year; <0.5%RH/year
- Output signal:RS485 (standard Modbus-RTU protocol)
- Response time: <1s
- Working Environment: Temperature: -55℃~120℃; Humidity: ≤95%RH
5.2 Wiring
5.3 Mechinical Drawing
6. WSS-24 Rain and snow sensor
6.1 Overview and Spec
- Supply voltage: 12~24V DC
- Measurement parameters: Rain or snow
- Working temperature: -30~70℃; humidity: 10~90%RH
- Storage temperature: -40~80℃; humidity: 10~90%RH
- Output signal: RS485 (standard Modbus-RTU protocol)
- Stability and response time: <1 second
6.2 Wiring
6.3 Mechinical Drawing
6.4 Installation Angle Requirements
During installation, the sensor sensing surface should be kept at a 15-degree angle to the horizontal plane to prevent rain and snow accumulation from affecting sensor measurement.
7. Carbon dioxide sensor
7.1 Overview and Spec
- Supply voltage: 12~24V DC
- Measurement parameters: Rain or snow
- Working temperature: -30~70℃; humidity: 10~90%RH
- Storage temperature: -40~80℃; humidity: 10~90%RH
- Output signal: RS485 (standard Modbus-RTU protocol)
- Stability and response time: <1 second