Last modified by Kilight Cao on 2025/07/22 16:13
From version 83.3
edited by Kilight Cao
on 2025/07/22 16:01
on 2025/07/22 16:01
Change comment:
There is no comment for this version
To version 81.15
edited by Mengting Qiu
on 2025/07/01 14:07
on 2025/07/01 14:07
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Kilight1 +XWiki.ting - Content
-
... ... @@ -93,15 +93,6 @@ 93 93 * Make sure the device is horizontal installed 94 94 * Device include electronic compass. No need to consider installation direction to get correct wind direction. 95 95 96 - 97 - 98 -== 1.4. RS485 Commands == 99 - 100 - 101 -The RS485 command is as follows: 102 - 103 - 104 - 105 105 = 2. WSS-08 ~-~- Optical Range Guage = 106 106 107 107 == 2.1 Overview and Spec == ... ... @@ -269,24 +269,27 @@ 269 269 270 270 Multiply by the default K-value (1000) to get the new K-value: 0.75×1000=750(Decimal) 271 271 272 -**2. Convert the (% style="color:#037691" %)new K-value(%%)to hexadecimal**:263 +**2. Convert the new K-value to hexadecimal**: 273 273 274 274 * 750(D) = 0x02EE(H) 275 275 276 276 **3. Send the calibration command to Sensor 2**: 277 277 278 -* Command Format: **0B 06 00 53 [(% style="color:#037691" %)K-value(%%) (2 bytes)] [CRC]** 279 -* Example for K-value 0x02EE: 0B 06 00 53 02 EE F8 5D 280 280 281 -(% style="color:red" %)**Notes:** 282 282 283 - ~1.Alwaysusethesensorwiththemosttrustedreadingas thereference(do notmodifyitsK-value).271 +if the value of sensor 1 is 1500 and the value of sensor 2 is 2000, it is necessary to keep the values around 1500if the value of sensor 1 is 1500 and the value of sensor 2 is 2000, it is necessary to keep the values around 1500. 284 284 285 - 2.ThedefaultK-value03E8 (1000) implies no scaling. Valuesbelow 03E8reducethe output; values above increase it.273 +Modify the K value of sensor 2: 286 286 287 -3. CRC is auto-generated by the tool (no manual calculation needed). 275 +* K value calculation as follows: 276 +* 1500/2000=0.75, 0.75*1000=750 277 +* Convert 750 to hexadecimal to 02EE. 278 +* Send command to sensor 2 279 +* Send:0B 06 00 53 02 EE F8 5D Send successfully and return this command 288 288 289 289 282 + 283 + 290 290 = 5. WSS-25 ~-~- Temperature, Humidity, Illuminance, Pressure = 291 291 292 292 ... ... @@ -582,7 +582,7 @@ 582 582 583 583 WS-K2: Bracket Kit for Pole installation 584 584 585 -WS-K2 dimension document, please see: 579 +WSSC-K2 dimension document, please see: 586 586 ))) 587 587 588 588 [[https:~~/~~/www.dropbox.com/sh/7wa2elfm2q8xq4l/AAB7ZB_gSVGrhmJEgU2LyTQNa?dl=0>>https://www.dropbox.com/sh/7wa2elfm2q8xq4l/AAB7ZB_gSVGrhmJEgU2LyTQNa?dl=0]]