... ... @@ -1,1 +1,1 @@
1 -XWiki.Kilight
1 +XWiki.ting
Content
... ... @@ -93,11 +93,6 @@
93 93  * Make sure the device is horizontal installed
94 94  * Device include electronic compass. No need to consider installation direction to get correct wind direction.
95 95  
96 -
97 -
98 -== 1.4. RS485 Commands ==
99 -
100 -
101 101  = 2. WSS-08 ~-~- Optical Range Guage =
102 102  
103 103  == 2.1 Overview and Spec ==
... ... @@ -265,24 +265,30 @@
265 265  
266 266  Multiply by the default K-value (1000) to get the new K-value: 0.75×1000=750(Decimal)
267 267  
268 -**2. Convert the (% style="color:#037691" %)new K-value(%%) to hexadecimal**:
263 +**2. Convert the (% style="color:#037691" %)S(%%)new K-value to hexadecimal**:
269 269  
270 270  * 750(D) = 0x02EE(H)
271 271  
272 272  **3. Send the calibration command to Sensor 2**:
273 273  
274 -* Command Format: **0B 06 00 53 [(% style="color:#037691" %)K-value(%%) (2 bytes)] [CRC]**
275 -* Example for K-value 0x02EE: 0B 06 00 53 02 EE F8 5D
269 +* Command Format: 0B 06 00 53 [K-value (2 bytes)] [CRC]
276 276  
277 -(% style="color:red" %)**Notes:**
278 278  
279 -~1. Always use the sensor with the most trusted reading as the reference (do not modify its K-value).
280 280  
281 -2. The default K-value 03E8 (1000) implies no scaling. Values below 03E8 reduce the output; values above increase it.
282 282  
283 -3. CRC is auto-generated by the tool (no manual calculation needed).
274 +if the value of sensor 1 is 1500 and the value of sensor 2 is 2000, it is necessary to keep the values around 1500if the value of sensor 1 is 1500 and the value of sensor 2 is 2000, it is necessary to keep the values around 1500.
284 284  
276 +Modify the K value of sensor 2:
285 285  
278 +* K value calculation as follows:
279 +* 1500/2000=0.75,  0.75*1000=750
280 +* Convert 750 to hexadecimal to 02EE.
281 +* Send command to sensor 2
282 +* Send:0B 06 00 53 02 EE F8 5D  Send successfully and return this command
283 +
284 +
285 +
286 +
286 286  = 5. WSS-25 ~-~- Temperature, Humidity, Illuminance, Pressure =
287 287  
288 288  
... ... @@ -578,7 +578,7 @@
578 578  
579 579  WS-K2: Bracket Kit for Pole installation
580 580  
581 -WS-K2 dimension document, please see:
582 +WSSC-K2 dimension document, please see:
582 582  )))
583 583  
584 584  [[https:~~/~~/www.dropbox.com/sh/7wa2elfm2q8xq4l/AAB7ZB_gSVGrhmJEgU2LyTQNa?dl=0>>https://www.dropbox.com/sh/7wa2elfm2q8xq4l/AAB7ZB_gSVGrhmJEgU2LyTQNa?dl=0]]