255 255  **Steps:**
256 256  
257 +**~1. Calculate the K-value ratio**:
257 257  
259 +Ratio=Desired Value/Current Value=1500/2000=0.75
258 258  
261 +Multiply by the default K-value (1000) to get the new K-value: 0.75×1000=750(Decimal)
259 259  
263 +**2. Convert the new K-value to hexadecimal**:
260 260  
265 +* 750(D) = 0x02EE
266 +
267 +
268 +
269 +
261 261  if the value of sensor 1 is 1500 and the value of sensor 2 is 2000, it is necessary to keep the values around 1500if the value of sensor 1 is 1500 and the value of sensor 2 is 2000, it is necessary to keep the values around 1500.
262 262  