... ... @@ -1,1 +1,1 @@ 1 -XWiki. ting1 +XWiki.Xiaoling - Content
-
... ... @@ -241,25 +241,43 @@ 241 241 242 242 In the event of deviations in the sensor values, calibration can be carried out by modifying the sensor's internal parameter: K-value parameter(**Default: 03E8(H)=1000(D)**). 243 243 244 -**Calibration Principle** 244 +(% style="color:#037691" %)**Calibration Principle** 245 245 246 246 The K-value scales the sensor's output. If multiple sensors measure the same parameter but show different values, adjust the K-value of the secondary sensor(s) to match the primary sensor's reading. 247 247 248 -**Step-by-Step Example** 248 +(% style="color:#037691" %)**Step-by-Step Example:** 249 249 250 - if the value of sensor 1 is 1500 and the value of sensor 2 is 2000, it is necessary to keep the values around 1500if the value of sensor1is 1500 and the valueof sensor 2 is 2000, it is necessary to keep the values around 1500.250 +**Scenario:** 251 251 252 -Modify the K value of sensor 2: 252 +* Sensor 1 (reference) reads 1500. 253 +* Sensor 2 reads 2000, but should match Sensor 1's value (~~1500). 253 253 254 -* K value calculation as follows: 255 -* 1500/2000=0.75, 0.75*1000=750 256 -* Convert 750 to hexadecimal to 02EE. 257 -* Send command to sensor 2 258 -* Send:0B 06 00 53 02 EE F8 5D Send successfully and return this command 255 +**Steps:** 259 259 257 +**~1. Calculate the K-value ratio**: 260 260 259 +Ratio=Desired Value/Current Value=1500/2000=0.75 261 261 261 +Multiply by the default K-value (1000) to get the new K-value: 0.75×1000=750(Decimal) 262 262 263 +**2. Convert the (% style="color:#037691" %)new K-value(%%) to hexadecimal**: 264 + 265 +* 750(D) = 0x02EE(H) 266 + 267 +**3. Send the calibration command to Sensor 2**: 268 + 269 +* Command Format: **0B 06 00 53 [(% style="color:#037691" %)K-value(%%) (2 bytes)] [CRC]** 270 +* Example for K-value 0x02EE: 0B 06 00 53 02 EE F8 5D 271 + 272 +(% style="color:red" %)**Notes:** 273 + 274 +~1. Always use the sensor with the most trusted reading as the reference (do not modify its K-value). 275 + 276 +2. The default K-value 03E8 (1000) implies no scaling. Values below 03E8 reduce the output; values above increase it. 277 + 278 +3. CRC is auto-generated by the tool (no manual calculation needed). 279 + 280 + 263 263 = 5. WSS-25 ~-~- Temperature, Humidity, Illuminance, Pressure = 264 264 265 265 ... ... @@ -555,7 +555,7 @@ 555 555 556 556 WS-K2: Bracket Kit for Pole installation 557 557 558 -WS SC-K2 dimension document, please see:576 +WS-K2 dimension document, please see: 559 559 ))) 560 560 561 561 [[https:~~/~~/www.dropbox.com/sh/7wa2elfm2q8xq4l/AAB7ZB_gSVGrhmJEgU2LyTQNa?dl=0>>https://www.dropbox.com/sh/7wa2elfm2q8xq4l/AAB7ZB_gSVGrhmJEgU2LyTQNa?dl=0]]