... ... @@ -245,8 +245,13 @@ 245 245 246 246 The K-value scales the sensor's output. If multiple sensors measure the same parameter but show different values, adjust the K-value of the secondary sensor(s) to match the primary sensor's reading. 247 247 248 -**Step-by-Step Example** 248 +**Step-by-Step Example:** 249 249 250 +Scenario: 251 + 252 +* Sensor 1 (reference) reads 1500. 253 +* Sensor 2 reads 2000, but should match Sensor 1's value (~~1500). 254 + 250 250 if the value of sensor 1 is 1500 and the value of sensor 2 is 2000, it is necessary to keep the values around 1500if the value of sensor 1 is 1500 and the value of sensor 2 is 2000, it is necessary to keep the values around 1500. 251 251 252 252 Modify the K value of sensor 2: