... ... @@ -237,25 +237,6 @@
237 237  [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/Dragino%20LoRaWAN%20Weather%20Station%20User%20Manual/WebHome/1656057377943-564.png?rev=1.1||alt="1656057377943-564.png"]]
238 238  
239 239  
240 -== 4.6 Calibration Values (K-value Adjustment) ==
241 -
242 -When sensor readings show deviations, calibration can be performed by modifying the K-value parameter in the sensor: K-value parameter(**Default: 03E8(h)=1000(D)**).
243 -
244 -For example:
245 -
246 -if the value of sensor 1 is 1500 and the value of sensor 2 is 2000, it is necessary to keep the values around 1500if the value of sensor 1 is 1500 and the value of sensor 2 is 2000, it is necessary to keep the values around 1500.
247 -
248 -Modify the K value of sensor 2:
249 -
250 -* K value calculation as follows:
251 -* 1500/2000=0.75,  0.75*1000=750
252 -* Convert 750 to hexadecimal to 02EE.
253 -* Send command to sensor 2
254 -* Send:0B 06 00 53 02 EE F8 5D  Send successfully and return this command
255 -
256 -