Changes for page

Last modified by Kilight Cao on 2025/07/22 16:13

From version 81.18
edited by Mengting Qiu
on 2025/07/01 14:12
Change comment: There is no comment for this version
To version 83.1
edited by Xiaoling
on 2025/07/22 14:50
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.ting
1 +XWiki.Xiaoling
Content
... ... @@ -267,16 +267,17 @@
267 267  **3. Send the calibration command to Sensor 2**:
268 268  
269 269  * Command Format: **0B 06 00 53 [(% style="color:#037691" %)K-value(%%) (2 bytes)] [CRC]**
270 +* Example for K-value 0x02EE: 0B 06 00 53 02 EE F8 5D
270 270  
271 -Example for K-value 0x02EE: 0B 06 00 53 02 EE F8 5D
272 +(% style="color:red" %)**Notes:**
272 272  
273 -Notes:
274 -Always use the sensor with the most trusted reading as the reference (do not modify its K-value).
275 -The default K-value 03E8 (1000) implies no scaling. Values below 03E8 reduce the output; values above increase it.
276 -CRC is auto-generated by the tool (no manual calculation needed).
274 +~1. Always use the sensor with the most trusted reading as the reference (do not modify its K-value).
277 277  
276 +2. The default K-value 03E8 (1000) implies no scaling. Values below 03E8 reduce the output; values above increase it.
278 278  
278 +3. CRC is auto-generated by the tool (no manual calculation needed).
279 279  
280 +
280 280  = 5. WSS-25 ~-~- Temperature, Humidity, Illuminance, Pressure =
281 281  
282 282  
... ... @@ -572,7 +572,7 @@
572 572  
573 573  WS-K2: Bracket Kit for Pole installation
574 574  
575 -WSSC-K2 dimension document, please see:
576 +WS-K2 dimension document, please see:
576 576  )))
577 577  
578 578  [[https:~~/~~/www.dropbox.com/sh/7wa2elfm2q8xq4l/AAB7ZB_gSVGrhmJEgU2LyTQNa?dl=0>>https://www.dropbox.com/sh/7wa2elfm2q8xq4l/AAB7ZB_gSVGrhmJEgU2LyTQNa?dl=0]]