... ... @@ -241,42 +241,30 @@ 241 241 242 242 In the event of deviations in the sensor values, calibration can be carried out by modifying the sensor's internal parameter: K-value parameter(**Default: 03E8(H)=1000(D)**). 243 243 244 - (% style="color:#037691" %)**Calibration Principle**244 +**Calibration Principle** 245 245 246 246 The K-value scales the sensor's output. If multiple sensors measure the same parameter but show different values, adjust the K-value of the secondary sensor(s) to match the primary sensor's reading. 247 247 248 - (% style="color:#037691" %)**Step-by-Step Example:**248 +**Step-by-Step Example:** 249 249 250 - **Scenario:**250 +Scenario: 251 251 252 252 * Sensor 1 (reference) reads 1500. 253 253 * Sensor 2 reads 2000, but should match Sensor 1's value (~~1500). 254 254 255 - **Steps:**255 +if the value of sensor 1 is 1500 and the value of sensor 2 is 2000, it is necessary to keep the values around 1500if the value of sensor 1 is 1500 and the value of sensor 2 is 2000, it is necessary to keep the values around 1500. 256 256 257 - **~1.Calculate the K-valueratio**:257 +Modify the K value of sensor 2: 258 258 259 -Ratio=Desired Value/Current Value=1500/2000=0.75 259 +* K value calculation as follows: 260 +* 1500/2000=0.75, 0.75*1000=750 261 +* Convert 750 to hexadecimal to 02EE. 262 +* Send command to sensor 2 263 +* Send:0B 06 00 53 02 EE F8 5D Send successfully and return this command 260 260 261 -Multiply by the default K-value (1000) to get the new K-value: 0.75×1000=750(Decimal) 262 262 263 -**2. Convert the (% style="color:#037691" %)new K-value(%%) to hexadecimal**: 264 264 265 -* 750(D) = 0x02EE(H) 266 266 267 -**3. Send the calibration command to Sensor 2**: 268 - 269 -* Command Format: **0B 06 00 53 [(% style="color:#037691" %)K-value(%%) (2 bytes)] [CRC]** 270 - 271 -Example for K-value 0x02EE: 0B 06 00 53 02 EE F8 5D 272 - 273 -Notes: 274 -Always use the sensor with the most trusted reading as the reference (do not modify its K-value). 275 -The default K-value 03E8 (1000) implies no scaling. Values below 03E8 reduce the output; values above increase it. 276 -CRC is auto-generated by the tool (no manual calculation needed). 277 - 278 - 279 - 280 280 = 5. WSS-25 ~-~- Temperature, Humidity, Illuminance, Pressure = 281 281 282 282