Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -239,44 +239,23 @@ 239 239 240 240 == 4.6 Calibration Values (K-value Adjustment) == 241 241 242 -In the event of deviations in the sensor values, calibration can be carried out by modifying the sensor's internal parameter: K-value parameter(**Default: 03E8( H)=1000(D)**).242 +In the event of deviations in the sensor values, calibration can be carried out by modifying the sensor's internal parameter: K-value parameter(**Default: 03E8(h)=1000(D)**). 243 243 244 - (% style="color:#037691"%)**Calibration Principle**244 +For example: 245 245 246 - TheK-valuescalesthesensor'soutput.Ifmultiple sensorsmeasurethesameparameterbutshowdifferent values,adjusttheK-value ofthesecondarysensor(s)tomatchtheprimary sensor'sreading.246 +if the value of sensor 1 is 1500 and the value of sensor 2 is 2000, it is necessary to keep the values around 1500if the value of sensor 1 is 1500 and the value of sensor 2 is 2000, it is necessary to keep the values around 1500. 247 247 248 - (% style="color:#037691"%)**Step-by-StepExample:**248 +Modify the K value of sensor 2: 249 249 250 -**Scenario:** 250 +* K value calculation as follows: 251 +* 1500/2000=0.75, 0.75*1000=750 252 +* Convert 750 to hexadecimal to 02EE. 253 +* Send command to sensor 2 254 +* Send:0B 06 00 53 02 EE F8 5D Send successfully and return this command 251 251 252 -* Sensor 1 (reference) reads 1500. 253 -* Sensor 2 reads 2000, but should match Sensor 1's value (~~1500). 254 254 255 -**Steps:** 256 256 257 -**~1. Calculate the K-value ratio**: 258 258 259 -Ratio=Desired Value/Current Value=1500/2000=0.75 260 - 261 -Multiply by the default K-value (1000) to get the new K-value: 0.75×1000=750(Decimal) 262 - 263 -**2. Convert the (% style="color:#037691" %)new K-value(%%) to hexadecimal**: 264 - 265 -* 750(D) = 0x02EE(H) 266 - 267 -**3. Send the calibration command to Sensor 2**: 268 - 269 -* Command Format: **0B 06 00 53 [(% style="color:#037691" %)K-value(%%) (2 bytes)] [CRC]** 270 - 271 -Example for K-value 0x02EE: 0B 06 00 53 02 EE F8 5D 272 - 273 -Notes: 274 -Always use the sensor with the most trusted reading as the reference (do not modify its K-value). 275 -The default K-value 03E8 (1000) implies no scaling. Values below 03E8 reduce the output; values above increase it. 276 -CRC is auto-generated by the tool (no manual calculation needed). 277 - 278 - 279 - 280 280 = 5. WSS-25 ~-~- Temperature, Humidity, Illuminance, Pressure = 281 281 282 282