Changes for page

Last modified by Kilight Cao on 2025/07/22 16:13

From version 81.18
edited by Mengting Qiu
on 2025/07/01 14:12
Change comment: There is no comment for this version
To version 81.16
edited by Mengting Qiu
on 2025/07/01 14:09
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -260,23 +260,30 @@
260 260  
261 261  Multiply by the default K-value (1000) to get the new K-value: 0.75×1000=750(Decimal)
262 262  
263 -**2. Convert the (% style="color:#037691" %)new K-value(%%) to hexadecimal**:
263 +**2. Convert the (% style="color:#037691" %)S(%%)new K-value to hexadecimal**:
264 264  
265 265  * 750(D) = 0x02EE(H)
266 266  
267 267  **3. Send the calibration command to Sensor 2**:
268 268  
269 -* Command Format: **0B 06 00 53 [(% style="color:#037691" %)K-value(%%) (2 bytes)] [CRC]**
269 +* Command Format: 0B 06 00 53 [K-value (2 bytes)] [CRC]
270 270  
271 -Example for K-value 0x02EE: 0B 06 00 53 02 EE F8 5D
272 272  
273 -Notes:
274 -Always use the sensor with the most trusted reading as the reference (do not modify its K-value).
275 -The default K-value 03E8 (1000) implies no scaling. Values below 03E8 reduce the output; values above increase it.
276 -CRC is auto-generated by the tool (no manual calculation needed).
277 277  
278 278  
274 +if the value of sensor 1 is 1500 and the value of sensor 2 is 2000, it is necessary to keep the values around 1500if the value of sensor 1 is 1500 and the value of sensor 2 is 2000, it is necessary to keep the values around 1500.
279 279  
276 +Modify the K value of sensor 2:
277 +
278 +* K value calculation as follows:
279 +* 1500/2000=0.75,  0.75*1000=750
280 +* Convert 750 to hexadecimal to 02EE.
281 +* Send command to sensor 2
282 +* Send:0B 06 00 53 02 EE F8 5D  Send successfully and return this command
283 +
284 +
285 +
286 +
280 280  = 5. WSS-25 ~-~- Temperature, Humidity, Illuminance, Pressure =
281 281  
282 282