... ... @@ -260,30 +260,23 @@
260 260  
261 261  Multiply by the default K-value (1000) to get the new K-value: 0.75×1000=750(Decimal)
262 262  
263 -**2. Convert the (% style="color:#037691" %)S(%%)new K-value to hexadecimal**:
263 +**2. Convert the (% style="color:#037691" %)new K-value(%%) to hexadecimal**:
264 264  
265 265  * 750(D) = 0x02EE(H)
266 266  
267 267  **3. Send the calibration command to Sensor 2**:
268 268  
269 -* Command Format: 0B 06 00 53 [K-value (2 bytes)] [CRC]
269 +* Command Format: **0B 06 00 53 [(% style="color:#037691" %)K-value(%%) (2 bytes)] [CRC]**
270 270  
271 +Example for K-value 0x02EE: 0B 06 00 53 02 EE F8 5D
271 271  
273 +Notes:
274 +Always use the sensor with the most trusted reading as the reference (do not modify its K-value).
275 +The default K-value 03E8 (1000) implies no scaling. Values below 03E8 reduce the output; values above increase it.
276 +CRC is auto-generated by the tool (no manual calculation needed).
272 272  
273 273  
274 -if the value of sensor 1 is 1500 and the value of sensor 2 is 2000, it is necessary to keep the values around 1500if the value of sensor 1 is 1500 and the value of sensor 2 is 2000, it is necessary to keep the values around 1500.
275 275  
276 -Modify the K value of sensor 2:
277 -
278 -* K value calculation as follows:
279 -* 1500/2000=0.75,  0.75*1000=750
280 -* Convert 750 to hexadecimal to 02EE.
281 -* Send command to sensor 2
282 -* Send:0B 06 00 53 02 EE F8 5D  Send successfully and return this command
283 -
284 -
285 -
286 -
287 287  = 5. WSS-25 ~-~- Temperature, Humidity, Illuminance, Pressure =
288 288  
289 289