Last modified by Kilight Cao on 2025/07/22 16:13
From version 81.15
edited by Mengting Qiu
on 2025/07/01 14:07
on 2025/07/01 14:07
Change comment:
There is no comment for this version
To version 81.16
edited by Mengting Qiu
on 2025/07/01 14:09
on 2025/07/01 14:09
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -260,14 +260,17 @@ 260 260 261 261 Multiply by the default K-value (1000) to get the new K-value: 0.75×1000=750(Decimal) 262 262 263 -**2. Convert the new K-value to hexadecimal**: 263 +**2. Convert the (% style="color:#037691" %)S(%%)new K-value to hexadecimal**: 264 264 265 265 * 750(D) = 0x02EE(H) 266 266 267 267 **3. Send the calibration command to Sensor 2**: 268 268 269 +* Command Format: 0B 06 00 53 [K-value (2 bytes)] [CRC] 269 269 270 270 272 + 273 + 271 271 if the value of sensor 1 is 1500 and the value of sensor 2 is 2000, it is necessary to keep the values around 1500if the value of sensor 1 is 1500 and the value of sensor 2 is 2000, it is necessary to keep the values around 1500. 272 272 273 273 Modify the K value of sensor 2: