... ... @@ -260,13 +260,17 @@ 260 260 261 261 Multiply by the default K-value (1000) to get the new K-value: 0.75×1000=750(Decimal) 262 262 263 -**2. Convert the new K-value to hexadecimal**: 263 +**2. Convert the (% style="color:#037691" %)S(%%)new K-value to hexadecimal**: 264 264 265 265 * 750(D) = 0x02EE(H) 266 266 267 +**3. Send the calibration command to Sensor 2**: 267 267 269 +* Command Format: 0B 06 00 53 [K-value (2 bytes)] [CRC] 268 268 269 269 272 + 273 + 270 270 if the value of sensor 1 is 1500 and the value of sensor 2 is 2000, it is necessary to keep the values around 1500if the value of sensor 1 is 1500 and the value of sensor 2 is 2000, it is necessary to keep the values around 1500. 271 271 272 272 Modify the K value of sensor 2: