Last modified by Kilight Cao on 2025/07/22 16:13
From version 81.13
edited by Mengting Qiu
on 2025/07/01 14:06
on 2025/07/01 14:06
Change comment:
There is no comment for this version
To version 83.2
edited by Kilight Cao
on 2025/07/22 15:59
on 2025/07/22 15:59
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. ting1 +XWiki.Kilight - Content
-
... ... @@ -93,6 +93,11 @@ 93 93 * Make sure the device is horizontal installed 94 94 * Device include electronic compass. No need to consider installation direction to get correct wind direction. 95 95 96 + 97 + 98 +== 1.4. RS485 Commands == 99 + 100 + 96 96 = 2. WSS-08 ~-~- Optical Range Guage = 97 97 98 98 == 2.1 Overview and Spec == ... ... @@ -260,26 +260,24 @@ 260 260 261 261 Multiply by the default K-value (1000) to get the new K-value: 0.75×1000=750(Decimal) 262 262 263 -**2. Convert the new K-value to hexadecimal**: 268 +**2. Convert the (% style="color:#037691" %)new K-value(%%) to hexadecimal**: 264 264 265 -* 750(D) = 0x02EE(H 270 +* 750(D) = 0x02EE(H) 266 266 272 +**3. Send the calibration command to Sensor 2**: 267 267 274 +* Command Format: **0B 06 00 53 [(% style="color:#037691" %)K-value(%%) (2 bytes)] [CRC]** 275 +* Example for K-value 0x02EE: 0B 06 00 53 02 EE F8 5D 268 268 277 +(% style="color:red" %)**Notes:** 269 269 270 - ifthe valueofsensor1 is 1500 andthevalue ofsensor2is 2000, itis necessaryto keep thevaluesaround1500ifthevalueofsensor1 is 1500 and thevalueofsensor2is2000,itisnecessary to keep thevalues around 1500.279 +~1. Always use the sensor with the most trusted reading as the reference (do not modify its K-value). 271 271 272 - ModifytheKvalue ofsensor2:281 +2. The default K-value 03E8 (1000) implies no scaling. Values below 03E8 reduce the output; values above increase it. 273 273 274 -* K value calculation as follows: 275 -* 1500/2000=0.75, 0.75*1000=750 276 -* Convert 750 to hexadecimal to 02EE. 277 -* Send command to sensor 2 278 -* Send:0B 06 00 53 02 EE F8 5D Send successfully and return this command 283 +3. CRC is auto-generated by the tool (no manual calculation needed). 279 279 280 280 281 - 282 - 283 283 = 5. WSS-25 ~-~- Temperature, Humidity, Illuminance, Pressure = 284 284 285 285 ... ... @@ -575,7 +575,7 @@ 575 575 576 576 WS-K2: Bracket Kit for Pole installation 577 577 578 -WS SC-K2 dimension document, please see:581 +WS-K2 dimension document, please see: 579 579 ))) 580 580 581 581 [[https:~~/~~/www.dropbox.com/sh/7wa2elfm2q8xq4l/AAB7ZB_gSVGrhmJEgU2LyTQNa?dl=0>>https://www.dropbox.com/sh/7wa2elfm2q8xq4l/AAB7ZB_gSVGrhmJEgU2LyTQNa?dl=0]]