Last modified by Kilight Cao on 2025/07/22 16:13
From version 78.3
edited by kai
on 2025/06/28 09:29
on 2025/06/28 09:29
Change comment:
There is no comment for this version
To version 81.2
edited by Mengting Qiu
on 2025/07/01 13:51
on 2025/07/01 13:51
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. kai1 +XWiki.ting - Content
-
... ... @@ -237,6 +237,25 @@ 237 237 [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/Dragino%20LoRaWAN%20Weather%20Station%20User%20Manual/WebHome/1656057377943-564.png?rev=1.1||alt="1656057377943-564.png"]] 238 238 239 239 240 +== 4.6 Calibration Values (K-value Adjustment) == 241 + 242 +When sensor readings show deviations, calibration can be performed by modifying the K-value parameter in the sensor: K-value parameter(**Default: 03E8(h)=1000(D)**). 243 + 244 +For example: 245 + 246 +if the value of sensor 1 is 1500 and the value of sensor 2 is 2000, it is necessary to keep the values around 1500if the value of sensor 1 is 1500 and the value of sensor 2 is 2000, it is necessary to keep the values around 1500. 247 + 248 +Modify the K value of sensor 2: 249 + 250 +* K value calculation as follows: 251 +* 1500/2000=0.75, 0.75*1000=750 252 +* Convert 750 to hexadecimal to 02EE. 253 +* Send command to sensor 2 254 +* Send:0B 06 00 53 02 EE F8 5D Send successfully and return this command 255 + 256 + 257 + 258 + 240 240 = 5. WSS-25 ~-~- Temperature, Humidity, Illuminance, Pressure = 241 241 242 242