... ... @@ -1,1 +1,1 @@
1 -XWiki.kai
1 +XWiki.ting
Content
... ... @@ -163,8 +163,8 @@
163 163  * Yearly Stability: ≤ ±2%
164 164  * Working Temperature: -30℃ ~~ 75℃
165 165  * Working Humidity: 10 ~~ 90%RH
166 -* Power Consumption: 3mA @ 12v  &  @5v
167 -* Stable Time:
166 +* Power Consumption: 5mA @ 12v  &  6mA @ 5v
167 +* Stable Time: 5s
168 168  
169 169  == 3.2 Wiring ==
170 170  
... ... @@ -237,6 +237,29 @@
237 237  [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/Dragino%20LoRaWAN%20Weather%20Station%20User%20Manual/WebHome/1656057377943-564.png?rev=1.1||alt="1656057377943-564.png"]]
238 238  
239 239  
240 +== 4.6 Calibration Values (K-value Adjustment) ==
241 +
242 +In the event of deviations in the sensor values, calibration can be carried out by modifying the sensor's internal parameter: K-value parameter(**Default: 03E8(H)=1000(D)**).
243 +
244 +**Calibration Principle**
245 +
246 +The K-value scales the sensor's output. If multiple sensors measure the same parameter but show different values, adjust the K-value of the secondary sensor(s) to match the primary sensor's reading.
247 +
248 +**Step-by-Step Example**
249 +
250 +if the value of sensor 1 is 1500 and the value of sensor 2 is 2000, it is necessary to keep the values around 1500if the value of sensor 1 is 1500 and the value of sensor 2 is 2000, it is necessary to keep the values around 1500.
251 +
252 +Modify the K value of sensor 2:
253 +
254 +* K value calculation as follows:
255 +* 1500/2000=0.75,  0.75*1000=750
256 +* Convert 750 to hexadecimal to 02EE.
257 +* Send command to sensor 2
258 +* Send:0B 06 00 53 02 EE F8 5D  Send successfully and return this command
259 +
260 +
261 +
262 +
240 240  = 5. WSS-25 ~-~- Temperature, Humidity, Illuminance, Pressure =
241 241  