Last modified by Xiaoling on 2025/05/07 17:24
Change comment:
Uploaded new attachment "image-20250505193603-10.png", version {1}
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.ting - Content
-
... ... @@ -24,7 +24,7 @@ 24 24 **Wind Direction:** 25 25 26 26 * Range: 0~~3599 27 -* Accuracy: ±3°27 +* Accuracy: +3° 28 28 * Ultrasonic measurement,no start wind strength needed 29 29 * Built-in electronic compass. No need to consider installation direction 30 30 ... ... @@ -31,12 +31,12 @@ 31 31 **Temperature:** 32 32 33 33 * Range: -40°C ~~ +80°C 34 -* Accuracy: ±0.5°C34 +* Accuracy: +0.5°C 35 35 36 36 **Humidity:** 37 37 38 38 * Range: 0 ~~ 99% RH 39 -* Accuracy Tolerance : Typ ±3% RH39 +* Accuracy Tolerance : Typ +3% RH 40 40 41 41 **Air Pressure:** 42 42 ... ... @@ -46,7 +46,7 @@ 46 46 **Noise:** 47 47 48 48 * Range: 30dB~~120dB 49 -* Accuracy: ±0.5dB49 +* Accuracy: +0.5dB 50 50 51 51 **PM2.5:** 52 52 ... ... @@ -57,13 +57,13 @@ 57 57 **PM10:** 58 58 59 59 * Range: 0~~1000ug/m3 60 -* Accuracy: ±3%FS60 +* Accuracy: +3%FS 61 61 * Resolution: 1ug/m3 62 62 63 63 **llumination:** 64 64 65 65 * Range: 0~~200k Lux 66 -* Accuracy: ±7%(25 °C)66 +* Accuracy: +7%(25 °C) 67 67 68 68 == 1.2 Wiring == 69 69 ... ... @@ -74,12 +74,12 @@ 74 74 75 75 === 1.2.2 New version wiring === 76 76 77 -[[image:image-202505051 93603-10.png||height="405" width="762"]]77 +[[image:image-20250505102835-7.png||height="409" width="739"]] 78 78 79 79 80 + 80 80 == 1.3 Mechinical Drawing == 81 81 82 - 83 83 (% class="lead" %) 84 84 **Device Dimension** 85 85 ... ... @@ -96,7 +96,6 @@ 96 96 97 97 == 2.1 Overview and Spec == 98 98 99 - 100 100 Older versions of interfaces New version of the interface 101 101 102 102 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/WSC2-LB_LoRaWAN_Weather_Station_User_Manual/WebHome/image-20240707215336-2.png?width=218&height=159&rev=1.1||alt="image-20240707215336-2.png" height="159" width="218"]] [[image:image-20250505190822-2.png||height="155" width="197"]] ... ... @@ -114,15 +114,13 @@ 114 114 115 115 [[image:image-20241127091433-1.jpeg||height="361" width="517"]] 116 116 117 - 118 118 === 2.2.2 New version wiring === 119 119 118 +[[image:image-20250505101405-5.png||height="381" width="748"]] 120 120 121 -[[image:image-20250505193511-9.png||height="392" width="708"]] 122 122 123 123 == 2.3 Mechinical Drawing == 124 124 125 - 126 126 (% class="lead" %) 127 127 **Device Dimension** 128 128 ... ... @@ -141,6 +141,7 @@ 141 141 [[image:image-20240714164856-4.png||height="250" width="433"]] 142 142 143 143 141 + 144 144 = 3. WSS-27 Photosynthetically Active Radiation Sensor = 145 145 146 146 == 3.1 Overview and Spec == ... ... @@ -148,47 +148,49 @@ 148 148 [[image:1746411474621-748.png||height="175" width="224"]] 149 149 150 150 * Input Power: 5~~24V DC 151 -* Measuring range: 0 ~~2500μmol/m2·s149 +* Measuring range: 0~2500μmol/m2·s 152 152 * Response time: <1S 153 153 * Resolution: 1μmol/m2·s 154 154 * Accuracy: ±2% 155 -* Response spectrum: 400 ~~700nm153 +* Response spectrum: 400~700nm 156 156 * Output signal: RS485 (standard Modbus-RTU protocol) 157 157 * Stability: change within one year <±2% 158 -* Working environment: -30℃ ~~75℃156 +* Working environment: -30℃~75℃ 159 159 160 160 == 3.2 Wiring == 161 161 162 -[[image:image-20250505193330-8.png||height="393" width="744"]] 163 163 161 +[[image:image-20250505102905-9.png||height="406" width="771"]] 162 + 164 164 == 3.3 Device Dimension == 165 165 166 166 [[image:1746424326901-763.png]] 167 167 168 168 169 -= 4. WSS-26 Simple Total Radiation Sensor = 170 170 169 += 4. WSS-06 Simple Total Radiation Sensor = 170 + 171 171 == 4.1 Overview and Spec == 172 172 173 173 [[image:1746423871465-411.png||height="217" width="278"]] 174 174 175 175 * (% id="cke_bm_101984S" style="display:none" %) (%%)Input Power: 5~~24V DC 176 -* Spectral Range: 0.3 ~~3μm (300~~3000nm)177 -* Measuring Range: 0 ~~2000W/m^^2^^176 +* Spectral Range: 0.3~3μm (300~3000nm) 177 +* Measuring Range: 0~2000W/m^^2^^ 178 178 * Resolution: 0.1W/m^^2^^ 179 179 * Measurement Accuracy: ±3% 180 180 * Output signal: RS485 (standard Modbus-RTU protocol) 181 -* Temperature Characteristics: ±2% (-10℃ ~~40℃)181 +* Temperature Characteristics: ±2% (-10℃~40℃) 182 182 * Response Time: <1s 183 183 * Annual Stability: ≤±2% 184 184 * Cosine Response: ≤7% (When the sun altitude angle is 10°) 185 185 * Azimuth Response Error: ≤5% (When the sun altitude angle is 10°) 186 -* Working environment: -40℃ ~~70℃186 +* Working environment: -40℃~70℃ 187 187 188 188 == 4.2 Wiring == 189 189 190 190 191 -[[image:image-202505051 93313-7.png||height="391" width="722"]]191 +[[image:image-20250505140615-10.png||height="419" width="791"]] 192 192 193 193 == 4.3 Device Dimension == 194 194 ... ... @@ -195,6 +195,7 @@ 195 195 [[image:1746424326901-763.png]] 196 196 197 197 198 + 198 198 = 5. WSS-25 Air Temperature and Humidity = 199 199 200 200 == 5.1 Overview and Spec == ... ... @@ -204,18 +204,18 @@ 204 204 205 205 * Supply voltage: 5~~24V DC 206 206 * Temperature Measuring Range: Standard -30~~70℃ or 0~~50℃ 207 -* Humidity Measuring Range: 0 ~~100%RH(Non-condensing state)208 -* Accuracy: ±0.2℃ (@25℃); ±3%RH (10% ~~90%)208 +* Humidity Measuring Range: 0~100%RH(Non-condensing state) 209 +* Accuracy: ±0.2℃ (@25℃); ±3%RH (10%~90%) 209 209 * Repeatability: ±0.1℃; ±0.1%RH 210 210 * Long-term stability: <0.04℃/year; <0.5%RH/year 211 211 * Output signal:RS485 (standard Modbus-RTU protocol) 212 212 * Response time: <1s 213 -* Working Environment: Temperature: -55℃ ~~120℃; Humidity: ≤95%RH214 +* Working Environment: Temperature: -55℃~120℃; Humidity: ≤95%RH 214 214 215 215 == 5.2 Wiring == 216 216 217 217 218 -[[image:image-202505051 93252-6.png||height="409" width="765"]]219 +[[image:image-20250505140636-11.png||height="419" width="794"]] 219 219 220 220 == 5.3 Device Dimension == 221 221 ... ... @@ -232,15 +232,16 @@ 232 232 233 233 * Supply voltage: 12~~24V DC 234 234 * Measurement parameters: Rain or snow 235 -* Working temperature: -30 ~~70℃; humidity: 10~~90%RH236 -* Storage temperature: -40~80℃; humidity: 10 ~~90%RH236 +* Working temperature: -30~70℃; humidity: 10~90%RH 237 +* Storage temperature: -40~80℃; humidity: 10~90%RH 237 237 * Output signal: RS485 (standard Modbus-RTU protocol) 238 238 * Stability and response time: <1 second 239 239 240 240 == 6.2 Wiring == 241 241 242 -[[image:image-20250505193053-5.png]] 243 243 244 +[[image:image-20250505144810-14.png]] 245 + 244 244 == 6.3 Device Dimension == 245 245 246 246 [[image:image-20250505144906-15.png]] ... ... @@ -248,7 +248,6 @@ 248 248 249 249 == 6.4 Installation Angle Requirements == 250 250 251 - 252 252 During installation, the sensor sensing surface should be kept at a 15-degree angle to the horizontal plane to prevent rain and snow accumulation from affecting sensor measurement. 253 253 254 254 [[image:image-20250505190308-23.png]] ... ... @@ -271,22 +271,22 @@ 271 271 272 272 273 273 * Measurement parameters: Carbon dioxide concentration 274 -* Measurement range: 0 ~~2000ppm, 0~~5000ppm, 0~~10000ppm275 +* Measurement range: 0-2000ppm, 0-5000ppm, 0-10000ppm 275 275 * Accuracy: ±3%F•S (25℃) 276 276 * Resolution: 1ppm 277 277 * Output signal: RS485 (standard Modbus-RTU protocol) 278 -* Working temperature: 0℃ ~~50℃279 -* Working humidity: 0 ~~95%RH279 +* Working temperature: 0℃~50℃ 280 +* Working humidity: 0~95%RH 280 280 281 281 **PM2.5 & PM10 Sensor** 282 282 283 283 * Measurement parameters: PM2.5 & PM10 concentration 284 -* Detection range: 0 ~~1000μg/m3285 +* Detection range: 0-1000μg/m3 285 285 * Resolution: 1μg/m3 286 286 * Accuracy: ±3%F•S (25℃) 287 -* Working temperature: -30℃ ~~50℃288 -* Storage temperature: -40℃ ~~60℃289 -* Working humidity: 15 ~~80%RH (no condensation)288 +* Working temperature: -30℃~50℃ 289 +* Storage temperature: -40℃~60℃ 290 +* Working humidity: 15~80%RH (no condensation) 290 290 * Temperature drift: 0.2%F•S/℃ 291 291 * Average current: 50mA@7V; 35mA@12V; 20mA@24V 292 292 * Stability: ≤2%F•S ... ... @@ -295,7 +295,7 @@ 295 295 296 296 == 7.2 Wiring == 297 297 298 -[[image:image-2025050519 3033-4.png||height="376" width="689"]]299 +[[image:image-20250505182902-17.png||height="372" width="698"]] 299 299 300 300 == 7.3 Device Dimension == 301 301 ... ... @@ -303,6 +303,8 @@ 303 303 [[image:1746440854349-915.png||height="312" width="588"]] 304 304 305 305 307 + 308 + 306 306 = 8. WSS-22 Integrated wind speed and direction sensor = 307 307 308 308 == 8.1 Overview and Spec == ... ... @@ -310,17 +310,17 @@ 310 310 [[image:1746441120854-584.png||height="271" width="394"]] 311 311 312 312 * Supply voltage: 5~~24V DC 313 -* Wind speed measurement range: 0 ~~30m/s; 0~~50m/s; 0~~60m/s;314 -* Wind direction measurement range: 0 ~~360°316 +* Wind speed measurement range: 0~30m/s; 0~50m/s; 0~60m/s; 317 +* Wind direction measurement range: 0~360° 315 315 * Starting wind speed: ≤0.3m/s 316 316 * Accuracy: ±(0.3+0.03V) m/s, ±1° 317 317 * Output signal: RS485 (standard Modbus-RTU protocol) 318 -* Working environment: Temperature: -30℃ ~~70℃; Humidity: ≤100%RH319 -* Storage environment: Temperature: -30℃ ~~70℃; Humidity: ≤100%RH321 +* Working environment: Temperature: -30℃~70℃; Humidity: ≤100%RH 322 +* Storage environment: Temperature: -30℃~70℃; Humidity: ≤100%RH 320 320 321 321 == 8.2 Wiring == 322 322 323 -[[image:image-202505051 92929-2.png||height="314" width="590"]]326 +[[image:image-20250505183552-18.png||height="288" width="550"]] 324 324 325 325 326 326 == 8.3 Device Dimension == ... ... @@ -332,12 +332,12 @@ 332 332 333 333 == 8.4 Installation method == 334 334 335 - 336 336 **The integrated wind speed and direction sensor (the outlet is pointing south, the opposite direction is north), the installation method is as follows:** 337 337 338 338 [[image:1746441560175-162.png||height="304" width="484"]] 339 339 340 340 343 + 341 341 = 9. WSS-21 Rain Sensor = 342 342 343 343 == 9.1 Overview and Spec == ... ... @@ -345,19 +345,19 @@ 345 345 [[image:image-20250505184214-19.png||height="324" width="320"]] 346 346 347 347 348 -* Rain-receiving port size: Φ200mm; sharp angle of blade: 40° ~~45°349 -* Range: 0 ~~100mm (range is limited to analog signal, RS485 signal is not measured)351 +* Rain-receiving port size: Φ200mm; sharp angle of blade: 40°~45° 352 +* Range: 0~100mm (range is limited to analog signal, RS485 signal is not measured) 350 350 * Resolution: 0.2mm 351 -* Rain intensity range: 0mm ~~4mm/min (maximum rain intensity allowed is 8mm/min)354 +* Rain intensity range: 0mm~4mm/min (maximum rain intensity allowed is 8mm/min) 352 352 * Accuracy: ≤±3% 353 353 * Output signal: RS485 (standard Modbus-RTU protocol) 354 -* Power supply voltage: 5 ~~24V DC355 -* Operating temperature: 0℃ ~~70℃ (optional heating function, can be as low as -40℃)357 +* Power supply voltage: 5~24V DC 358 +* Operating temperature: 0℃~70℃ (optional heating function, can be as low as -40℃) 356 356 * Operating humidity: <100% (no condensation) 357 357 358 358 == 9.2 Wiring == 359 359 360 -[[image:image-202505051 92952-3.png||height="305" width="581"]]363 +[[image:image-20250505184559-21.png||height="335" width="631"]] 361 361 362 362 363 363 == 9.3 Device Dimension ==