Last modified by Xiaoling on 2025/05/07 17:24
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. ting1 +XWiki.Xiaoling - Content
-
... ... @@ -24,7 +24,7 @@ 24 24 **Wind Direction:** 25 25 26 26 * Range: 0~~3599 27 -* Accuracy: +3°27 +* Accuracy: ±3° 28 28 * Ultrasonic measurement,no start wind strength needed 29 29 * Built-in electronic compass. No need to consider installation direction 30 30 ... ... @@ -31,12 +31,12 @@ 31 31 **Temperature:** 32 32 33 33 * Range: -40°C ~~ +80°C 34 -* Accuracy: +0.5°C34 +* Accuracy: ±0.5°C 35 35 36 36 **Humidity:** 37 37 38 38 * Range: 0 ~~ 99% RH 39 -* Accuracy Tolerance : Typ +3% RH39 +* Accuracy Tolerance : Typ ±3% RH 40 40 41 41 **Air Pressure:** 42 42 ... ... @@ -46,7 +46,7 @@ 46 46 **Noise:** 47 47 48 48 * Range: 30dB~~120dB 49 -* Accuracy: +0.5dB49 +* Accuracy: ±0.5dB 50 50 51 51 **PM2.5:** 52 52 ... ... @@ -57,13 +57,13 @@ 57 57 **PM10:** 58 58 59 59 * Range: 0~~1000ug/m3 60 -* Accuracy: +3%FS60 +* Accuracy: ±3%FS 61 61 * Resolution: 1ug/m3 62 62 63 63 **llumination:** 64 64 65 65 * Range: 0~~200k Lux 66 -* Accuracy: +7%(25 °C)66 +* Accuracy: ±7%(25 °C) 67 67 68 68 == 1.2 Wiring == 69 69 ... ... @@ -77,9 +77,9 @@ 77 77 [[image:image-20250505193603-10.png||height="405" width="762"]] 78 78 79 79 80 - 81 81 == 1.3 Mechinical Drawing == 82 82 82 + 83 83 (% class="lead" %) 84 84 **Device Dimension** 85 85 ... ... @@ -96,6 +96,7 @@ 96 96 97 97 == 2.1 Overview and Spec == 98 98 99 + 99 99 Older versions of interfaces New version of the interface 100 100 101 101 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/WSC2-LB_LoRaWAN_Weather_Station_User_Manual/WebHome/image-20240707215336-2.png?width=218&height=159&rev=1.1||alt="image-20240707215336-2.png" height="159" width="218"]] [[image:image-20250505190822-2.png||height="155" width="197"]] ... ... @@ -113,13 +113,15 @@ 113 113 114 114 [[image:image-20241127091433-1.jpeg||height="361" width="517"]] 115 115 117 + 116 116 === 2.2.2 New version wiring === 117 117 120 + 118 118 [[image:image-20250505193511-9.png||height="392" width="708"]] 119 119 120 - 121 121 == 2.3 Mechinical Drawing == 122 122 125 + 123 123 (% class="lead" %) 124 124 **Device Dimension** 125 125 ... ... @@ -138,7 +138,6 @@ 138 138 [[image:image-20240714164856-4.png||height="250" width="433"]] 139 139 140 140 141 - 142 142 = 3. WSS-27 Photosynthetically Active Radiation Sensor = 143 143 144 144 == 3.1 Overview and Spec == ... ... @@ -146,14 +146,14 @@ 146 146 [[image:1746411474621-748.png||height="175" width="224"]] 147 147 148 148 * Input Power: 5~~24V DC 149 -* Measuring range: 0 ~2500μmol/m2·s151 +* Measuring range: 0~~2500μmol/m2·s 150 150 * Response time: <1S 151 151 * Resolution: 1μmol/m2·s 152 152 * Accuracy: ±2% 153 -* Response spectrum: 400 ~700nm155 +* Response spectrum: 400~~700nm 154 154 * Output signal: RS485 (standard Modbus-RTU protocol) 155 155 * Stability: change within one year <±2% 156 -* Working environment: -30℃ ~75℃158 +* Working environment: -30℃~~75℃ 157 157 158 158 == 3.2 Wiring == 159 159 ... ... @@ -164,25 +164,24 @@ 164 164 [[image:1746424326901-763.png]] 165 165 166 166 169 += 4. WSS-26 Simple Total Radiation Sensor = 167 167 168 -= 4. WSS-06 Simple Total Radiation Sensor = 169 - 170 170 == 4.1 Overview and Spec == 171 171 172 172 [[image:1746423871465-411.png||height="217" width="278"]] 173 173 174 174 * (% id="cke_bm_101984S" style="display:none" %) (%%)Input Power: 5~~24V DC 175 -* Spectral Range: 0.3 ~3μm (300~3000nm)176 -* Measuring Range: 0 ~2000W/m^^2^^176 +* Spectral Range: 0.3~~3μm (300~~3000nm) 177 +* Measuring Range: 0~~2000W/m^^2^^ 177 177 * Resolution: 0.1W/m^^2^^ 178 178 * Measurement Accuracy: ±3% 179 179 * Output signal: RS485 (standard Modbus-RTU protocol) 180 -* Temperature Characteristics: ±2% (-10℃ ~40℃)181 +* Temperature Characteristics: ±2% (-10℃~~40℃) 181 181 * Response Time: <1s 182 182 * Annual Stability: ≤±2% 183 183 * Cosine Response: ≤7% (When the sun altitude angle is 10°) 184 184 * Azimuth Response Error: ≤5% (When the sun altitude angle is 10°) 185 -* Working environment: -40℃ ~70℃186 +* Working environment: -40℃~~70℃ 186 186 187 187 == 4.2 Wiring == 188 188 ... ... @@ -194,7 +194,6 @@ 194 194 [[image:1746424326901-763.png]] 195 195 196 196 197 - 198 198 = 5. WSS-25 Air Temperature and Humidity = 199 199 200 200 == 5.1 Overview and Spec == ... ... @@ -204,13 +204,13 @@ 204 204 205 205 * Supply voltage: 5~~24V DC 206 206 * Temperature Measuring Range: Standard -30~~70℃ or 0~~50℃ 207 -* Humidity Measuring Range: 0 ~100%RH(Non-condensing state)208 -* Accuracy: ±0.2℃ (@25℃); ±3%RH (10% ~90%)207 +* Humidity Measuring Range: 0~~100%RH(Non-condensing state) 208 +* Accuracy: ±0.2℃ (@25℃); ±3%RH (10%~~90%) 209 209 * Repeatability: ±0.1℃; ±0.1%RH 210 210 * Long-term stability: <0.04℃/year; <0.5%RH/year 211 211 * Output signal:RS485 (standard Modbus-RTU protocol) 212 212 * Response time: <1s 213 -* Working Environment: Temperature: -55℃ ~120℃; Humidity: ≤95%RH213 +* Working Environment: Temperature: -55℃~~120℃; Humidity: ≤95%RH 214 214 215 215 == 5.2 Wiring == 216 216 ... ... @@ -232,8 +232,8 @@ 232 232 233 233 * Supply voltage: 12~~24V DC 234 234 * Measurement parameters: Rain or snow 235 -* Working temperature: -30 ~70℃; humidity: 10~90%RH236 -* Storage temperature: -40~80℃; humidity: 10 ~90%RH235 +* Working temperature: -30~~70℃; humidity: 10~~90%RH 236 +* Storage temperature: -40~80℃; humidity: 10~~90%RH 237 237 * Output signal: RS485 (standard Modbus-RTU protocol) 238 238 * Stability and response time: <1 second 239 239 ... ... @@ -248,6 +248,7 @@ 248 248 249 249 == 6.4 Installation Angle Requirements == 250 250 251 + 251 251 During installation, the sensor sensing surface should be kept at a 15-degree angle to the horizontal plane to prevent rain and snow accumulation from affecting sensor measurement. 252 252 253 253 [[image:image-20250505190308-23.png]] ... ... @@ -270,22 +270,22 @@ 270 270 271 271 272 272 * Measurement parameters: Carbon dioxide concentration 273 -* Measurement range: 0 -2000ppm, 0-5000ppm, 0-10000ppm274 +* Measurement range: 0~~2000ppm, 0~~5000ppm, 0~~10000ppm 274 274 * Accuracy: ±3%F•S (25℃) 275 275 * Resolution: 1ppm 276 276 * Output signal: RS485 (standard Modbus-RTU protocol) 277 -* Working temperature: 0℃ ~50℃278 -* Working humidity: 0 ~95%RH278 +* Working temperature: 0℃~~50℃ 279 +* Working humidity: 0~~95%RH 279 279 280 280 **PM2.5 & PM10 Sensor** 281 281 282 282 * Measurement parameters: PM2.5 & PM10 concentration 283 -* Detection range: 0 -1000μg/m3284 +* Detection range: 0~~1000μg/m3 284 284 * Resolution: 1μg/m3 285 285 * Accuracy: ±3%F•S (25℃) 286 -* Working temperature: -30℃ ~50℃287 -* Storage temperature: -40℃ ~60℃288 -* Working humidity: 15 ~80%RH (no condensation)287 +* Working temperature: -30℃~~50℃ 288 +* Storage temperature: -40℃~~60℃ 289 +* Working humidity: 15~~80%RH (no condensation) 289 289 * Temperature drift: 0.2%F•S/℃ 290 290 * Average current: 50mA@7V; 35mA@12V; 20mA@24V 291 291 * Stability: ≤2%F•S ... ... @@ -302,8 +302,6 @@ 302 302 [[image:1746440854349-915.png||height="312" width="588"]] 303 303 304 304 305 - 306 - 307 307 = 8. WSS-22 Integrated wind speed and direction sensor = 308 308 309 309 == 8.1 Overview and Spec == ... ... @@ -311,13 +311,13 @@ 311 311 [[image:1746441120854-584.png||height="271" width="394"]] 312 312 313 313 * Supply voltage: 5~~24V DC 314 -* Wind speed measurement range: 0 ~30m/s; 0~50m/s; 0~60m/s;315 -* Wind direction measurement range: 0 ~360°313 +* Wind speed measurement range: 0~~30m/s; 0~~50m/s; 0~~60m/s; 314 +* Wind direction measurement range: 0~~360° 316 316 * Starting wind speed: ≤0.3m/s 317 317 * Accuracy: ±(0.3+0.03V) m/s, ±1° 318 318 * Output signal: RS485 (standard Modbus-RTU protocol) 319 -* Working environment: Temperature: -30℃ ~70℃; Humidity: ≤100%RH320 -* Storage environment: Temperature: -30℃ ~70℃; Humidity: ≤100%RH318 +* Working environment: Temperature: -30℃~~70℃; Humidity: ≤100%RH 319 +* Storage environment: Temperature: -30℃~~70℃; Humidity: ≤100%RH 321 321 322 322 == 8.2 Wiring == 323 323 ... ... @@ -333,12 +333,12 @@ 333 333 334 334 == 8.4 Installation method == 335 335 335 + 336 336 **The integrated wind speed and direction sensor (the outlet is pointing south, the opposite direction is north), the installation method is as follows:** 337 337 338 338 [[image:1746441560175-162.png||height="304" width="484"]] 339 339 340 340 341 - 342 342 = 9. WSS-21 Rain Sensor = 343 343 344 344 == 9.1 Overview and Spec == ... ... @@ -346,14 +346,14 @@ 346 346 [[image:image-20250505184214-19.png||height="324" width="320"]] 347 347 348 348 349 -* Rain-receiving port size: Φ200mm; sharp angle of blade: 40° ~45°350 -* Range: 0 ~100mm (range is limited to analog signal, RS485 signal is not measured)348 +* Rain-receiving port size: Φ200mm; sharp angle of blade: 40°~~45° 349 +* Range: 0~~100mm (range is limited to analog signal, RS485 signal is not measured) 351 351 * Resolution: 0.2mm 352 -* Rain intensity range: 0mm ~4mm/min (maximum rain intensity allowed is 8mm/min)351 +* Rain intensity range: 0mm~~4mm/min (maximum rain intensity allowed is 8mm/min) 353 353 * Accuracy: ≤±3% 354 354 * Output signal: RS485 (standard Modbus-RTU protocol) 355 -* Power supply voltage: 5 ~24V DC356 -* Operating temperature: 0℃ ~70℃ (optional heating function, can be as low as -40℃)354 +* Power supply voltage: 5~~24V DC 355 +* Operating temperature: 0℃~~70℃ (optional heating function, can be as low as -40℃) 357 357 * Operating humidity: <100% (no condensation) 358 358 359 359 == 9.2 Wiring ==