Last modified by Xiaoling on 2025/05/07 17:24
Change comment:
Uploaded new attachment "1746441560175-162.png", version {1}
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 4 removed)
Details
- Page properties
-
- Content
-
... ... @@ -151,12 +151,14 @@ 151 151 * Stability: change within one year <±2% 152 152 * Working environment: -30℃~75℃ 153 153 154 + 155 + 154 154 == 3.2 Wiring == 155 155 156 156 157 157 [[image:image-20250505102905-9.png||height="406" width="771"]] 158 158 159 -== 3.3 DeviceDimension==161 +== 3.3 Mechinical Drawing == 160 160 161 161 [[image:1746424326901-763.png]] 162 162 ... ... @@ -181,12 +181,13 @@ 181 181 * Azimuth Response Error: ≤5% (When the sun altitude angle is 10°) 182 182 * Working environment: -40℃~70℃ 183 183 186 + 184 184 == 4.2 Wiring == 185 185 186 186 187 187 [[image:image-20250505140615-10.png||height="419" width="791"]] 188 188 189 -== 4.3 DeviceDimension==192 +== 4.3 Mechinical Drawing == 190 190 191 191 [[image:1746424326901-763.png]] 192 192 ... ... @@ -209,12 +209,13 @@ 209 209 * Response time: <1s 210 210 * Working Environment: Temperature: -55℃~120℃; Humidity: ≤95%RH 211 211 215 + 212 212 == 5.2 Wiring == 213 213 214 214 215 215 [[image:image-20250505140636-11.png||height="419" width="794"]] 216 216 217 -== 5.3 DeviceDimension==221 +== 5.3 Mechinical Drawing == 218 218 219 219 220 220 [[image:1746425244897-496.png||height="363" width="684"]] ... ... @@ -234,12 +234,13 @@ 234 234 * Output signal: RS485 (standard Modbus-RTU protocol) 235 235 * Stability and response time: <1 second 236 236 241 + 237 237 == 6.2 Wiring == 238 238 239 239 240 240 [[image:image-20250505144810-14.png]] 241 241 242 -== 6.3 DeviceDimension==247 +== 6.3 Mechinical Drawing == 243 243 244 244 [[image:image-20250505144906-15.png]] 245 245 ... ... @@ -251,7 +251,7 @@ 251 251 [[image:image-20250505145005-16.png]] 252 252 253 253 254 -= 7. WSS-23Carbon dioxide sensor =259 += 7. Carbon dioxide sensor = 255 255 256 256 == 7.1 Overview and Spec == 257 257 ... ... @@ -258,94 +258,12 @@ 258 258 [[image:1746427977346-600.png||height="261" width="318"]] 259 259 260 260 261 -* Supply voltage: 7~~24V DC 262 -* Measurement parameters: Carbon dioxide concentration 263 -* Measurement range: 0-2000ppm, 0-5000ppm, 0-10000ppm 264 -* Accuracy: ±3%F•S (25℃) 265 -* Resolution: 1ppm 266 +* Supply voltage: 12~~24V DC 267 +* Measurement parameters: Rain or snow 268 +* Working temperature: -30~70℃; humidity: 10~90%RH 269 +* Storage temperature: -40~80℃; humidity: 10~90%RH 266 266 * Output signal: RS485 (standard Modbus-RTU protocol) 267 -* Working temperature: 0℃~50℃ 268 -* Working humidity: 0~95%RH 269 -* Average current: Peak value ≤200mA; average 85 mA 270 -* Warm-up time: 3min 271 -* Response time: <90s 272 -* Stability: ≤2% F•S 271 +* Stability and response time: <1 second 273 273 274 -== 7.2 Wiring == 275 275 276 -[[image:image-20250505182902-17.png||height="372" width="698"]] 277 - 278 -== 7.3 Device Dimension == 279 - 280 - 281 -[[image:1746440854349-915.png||height="312" width="588"]] 282 - 283 - 284 - 285 - 286 -= 8. WSS-22 Integrated wind speed and direction sensor = 287 - 288 -== 8.1 Overview and Spec == 289 - 290 -[[image:1746441120854-584.png||height="271" width="394"]] 291 - 292 -* Supply voltage: 5~~24V DC 293 -* Wind speed measurement range: 0~30m/s; 0~50m/s; 0~60m/s; 294 -* Wind direction measurement range: 0~360° 295 -* Starting wind speed: ≤0.3m/s 296 -* Accuracy: ±(0.3+0.03V) m/s, ±1° 297 -* Output signal: RS485 (standard Modbus-RTU protocol) 298 -* Working environment: Temperature: -30℃~70℃; Humidity: ≤100%RH 299 -* Storage environment: Temperature: -30℃~70℃; Humidity: ≤100%RH 300 - 301 - 302 -== 8.2 Wiring == 303 - 304 -[[image:image-20250505183552-18.png||height="288" width="550"]] 305 - 306 - 307 -== 8.3 Device Dimension == 308 - 309 -[[image:1746441469178-155.png||height="372" width="405"]] 310 - 311 -[[image:1746441481289-965.png||height="370" width="404"]] 312 - 313 - 314 -== 8.4 Installation method == 315 - 316 -**The integrated wind speed and direction sensor (the outlet is pointing south, the opposite direction is north), the installation method is as follows:** 317 - 318 -[[image:1746441560175-162.png||height="304" width="484"]] 319 - 320 - 321 - 322 -= 9. WSS-21 Rain Sensor = 323 - 324 -== 9.1 Overview and Spec == 325 - 326 -[[image:image-20250505184214-19.png||height="324" width="320"]] 327 - 328 - 329 -* Rain-receiving port size: Φ200mm; sharp angle of blade: 40°~45° 330 -* Range: 0~100mm (range is limited to analog signal, RS485 signal is not measured) 331 -* Resolution: 0.2mm 332 -* Rain intensity range: 0mm~4mm/min (maximum rain intensity allowed is 8mm/min) 333 -* Accuracy: ≤±3% 334 -* Output signal: RS485 (standard Modbus-RTU protocol) 335 -* Power supply voltage: 5~24V DC 336 -* Operating temperature: 0℃~70℃ (optional heating function, can be as low as -40℃) 337 -* Operating humidity: <100% (no condensation) 338 - 339 -== 9.2 Wiring == 340 - 341 -[[image:image-20250505184559-21.png||height="335" width="631"]] 342 - 343 - 344 -== 9.3 Device Dimension == 345 - 346 - 347 -[[image:image-20250505184528-20.png||height="468" width="471"]] 348 - 349 -[[image:image-20250505185334-22.png||height="533" width="470"]] 350 - 351 351
- image-20250505184214-19.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ting - Size
-
... ... @@ -1,1 +1,0 @@ 1 -239.8 KB - Content
- image-20250505184528-20.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ting - Size
-
... ... @@ -1,1 +1,0 @@ 1 -125.8 KB - Content
- image-20250505184559-21.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ting - Size
-
... ... @@ -1,1 +1,0 @@ 1 -291.8 KB - Content
- image-20250505185334-22.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ting - Size
-
... ... @@ -1,1 +1,0 @@ 1 -109.7 KB - Content