Last modified by Xiaoling on 2025/05/07 17:24
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -151,14 +151,12 @@ 151 151 * Stability: change within one year <±2% 152 152 * Working environment: -30℃~75℃ 153 153 154 - 155 - 156 156 == 3.2 Wiring == 157 157 158 158 159 159 [[image:image-20250505102905-9.png||height="406" width="771"]] 160 160 161 -== 3.3 MechinicalDrawing==159 +== 3.3 Device Dimension == 162 162 163 163 [[image:1746424326901-763.png]] 164 164 ... ... @@ -183,13 +183,12 @@ 183 183 * Azimuth Response Error: ≤5% (When the sun altitude angle is 10°) 184 184 * Working environment: -40℃~70℃ 185 185 186 - 187 187 == 4.2 Wiring == 188 188 189 189 190 190 [[image:image-20250505140615-10.png||height="419" width="791"]] 191 191 192 -== 4.3 MechinicalDrawing==189 +== 4.3 Device Dimension == 193 193 194 194 [[image:1746424326901-763.png]] 195 195 ... ... @@ -212,13 +212,12 @@ 212 212 * Response time: <1s 213 213 * Working Environment: Temperature: -55℃~120℃; Humidity: ≤95%RH 214 214 215 - 216 216 == 5.2 Wiring == 217 217 218 218 219 219 [[image:image-20250505140636-11.png||height="419" width="794"]] 220 220 221 -== 5.3 MechinicalDrawing==217 +== 5.3 Device Dimension == 222 222 223 223 224 224 [[image:1746425244897-496.png||height="363" width="684"]] ... ... @@ -238,13 +238,12 @@ 238 238 * Output signal: RS485 (standard Modbus-RTU protocol) 239 239 * Stability and response time: <1 second 240 240 241 - 242 242 == 6.2 Wiring == 243 243 244 244 245 245 [[image:image-20250505144810-14.png]] 246 246 247 -== 6.3 MechinicalDrawing==242 +== 6.3 Device Dimension == 248 248 249 249 [[image:image-20250505144906-15.png]] 250 250 ... ... @@ -256,7 +256,7 @@ 256 256 [[image:image-20250505145005-16.png]] 257 257 258 258 259 -= 7. 254 += 7. WSS-23 Carbon dioxide sensor = 260 260 261 261 == 7.1 Overview and Spec == 262 262 ... ... @@ -263,12 +263,94 @@ 263 263 [[image:1746427977346-600.png||height="261" width="318"]] 264 264 265 265 266 -* Supply voltage: 12~~24V DC 267 -* Measurement parameters: Rain or snow 268 -* Working temperature: -30~70℃; humidity: 10~90%RH 269 -* Storage temperature: -40~80℃; humidity: 10~90%RH 261 +* Supply voltage: 7~~24V DC 262 +* Measurement parameters: Carbon dioxide concentration 263 +* Measurement range: 0-2000ppm, 0-5000ppm, 0-10000ppm 264 +* Accuracy: ±3%F•S (25℃) 265 +* Resolution: 1ppm 270 270 * Output signal: RS485 (standard Modbus-RTU protocol) 271 -* Stability and response time: <1 second 267 +* Working temperature: 0℃~50℃ 268 +* Working humidity: 0~95%RH 269 +* Average current: Peak value ≤200mA; average 85 mA 270 +* Warm-up time: 3min 271 +* Response time: <90s 272 +* Stability: ≤2% F•S 272 272 274 +== 7.2 Wiring == 273 273 276 +[[image:image-20250505182902-17.png||height="372" width="698"]] 277 + 278 +== 7.3 Device Dimension == 279 + 280 + 281 +[[image:1746440854349-915.png||height="312" width="588"]] 282 + 283 + 284 + 285 + 286 += 8. WSS-22 Integrated wind speed and direction sensor = 287 + 288 +== 8.1 Overview and Spec == 289 + 290 +[[image:1746441120854-584.png||height="271" width="394"]] 291 + 292 +* Supply voltage: 5~~24V DC 293 +* Wind speed measurement range: 0~30m/s; 0~50m/s; 0~60m/s; 294 +* Wind direction measurement range: 0~360° 295 +* Starting wind speed: ≤0.3m/s 296 +* Accuracy: ±(0.3+0.03V) m/s, ±1° 297 +* Output signal: RS485 (standard Modbus-RTU protocol) 298 +* Working environment: Temperature: -30℃~70℃; Humidity: ≤100%RH 299 +* Storage environment: Temperature: -30℃~70℃; Humidity: ≤100%RH 300 + 301 + 302 +== 8.2 Wiring == 303 + 304 +[[image:image-20250505183552-18.png||height="288" width="550"]] 305 + 306 + 307 +== 8.3 Device Dimension == 308 + 309 +[[image:1746441469178-155.png||height="372" width="405"]] 310 + 311 +[[image:1746441481289-965.png||height="370" width="404"]] 312 + 313 + 314 +== 8.4 Installation method == 315 + 316 +**The integrated wind speed and direction sensor (the outlet is pointing south, the opposite direction is north), the installation method is as follows:** 317 + 318 +[[image:1746441560175-162.png||height="304" width="484"]] 319 + 320 + 321 + 322 += 9. WSS-21 Rain Sensor = 323 + 324 +== 9.1 Overview and Spec == 325 + 326 +[[image:image-20250505184214-19.png||height="324" width="320"]] 327 + 328 + 329 +* Rain-receiving port size: Φ200mm; sharp angle of blade: 40°~45° 330 +* Range: 0~100mm (range is limited to analog signal, RS485 signal is not measured) 331 +* Resolution: 0.2mm 332 +* Rain intensity range: 0mm~4mm/min (maximum rain intensity allowed is 8mm/min) 333 +* Accuracy: ≤±3% 334 +* Output signal: RS485 (standard Modbus-RTU protocol) 335 +* Power supply voltage: 5~24V DC 336 +* Operating temperature: 0℃~70℃ (optional heating function, can be as low as -40℃) 337 +* Operating humidity: <100% (no condensation) 338 + 339 +== 9.2 Wiring == 340 + 341 +[[image:image-20250505184559-21.png||height="335" width="631"]] 342 + 343 + 344 +== 9.3 Device Dimension == 345 + 346 + 347 +[[image:image-20250505184528-20.png||height="468" width="471"]] 348 + 349 +[[image:image-20250505185334-22.png||height="533" width="470"]] 350 + 274 274
- image-20250505184559-21.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +291.8 KB - Content
- image-20250505185334-22.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +109.7 KB - Content