Last modified by Xiaoling on 2025/05/07 17:24
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -150,10 +150,9 @@ 150 150 * Output signal: RS485 (standard Modbus-RTU protocol) 151 151 * Stability: change within one year <±2% 152 152 * Working environment: -30℃~75℃ 153 -* Impedance requirements for current signals 154 154 155 - [[image:image-20250505102448-6.png]] 156 156 155 + 157 157 == 3.2 Wiring == 158 158 159 159 ... ... @@ -165,7 +165,7 @@ 165 165 166 166 167 167 168 -= 4. 167 += 4. WSS-06 Simple Total Radiation Sensor = 169 169 170 170 == 4.1 Overview and Spec == 171 171 ... ... @@ -183,15 +183,12 @@ 183 183 * Cosine Response: ≤7% (When the sun altitude angle is 10°) 184 184 * Azimuth Response Error: ≤5% (When the sun altitude angle is 10°) 185 185 * Working environment: -40℃~70℃ 186 -* Impedance requirements for current signals 187 187 188 - [[image:image-20250505102448-6.png]] 189 189 190 - 191 191 == 4.2 Wiring == 192 192 193 193 194 -[[image:image-2025050510 2905-9.png||height="406" width="771"]]190 +[[image:image-20250505140615-10.png||height="419" width="791"]] 195 195 196 196 == 4.3 Mechinical Drawing == 197 197 ... ... @@ -199,7 +199,7 @@ 199 199 200 200 201 201 202 -= 5. 198 += 5. WSS-25 Air Temperature and Humidity = 203 203 204 204 == 5.1 Overview and Spec == 205 205 ... ... @@ -206,8 +206,62 @@ 206 206 [[image:1746424465810-974.png||height="325" width="288"]] 207 207 208 208 205 +* Supply voltage: 5~~24V DC 206 +* Temperature Measuring Range: Standard -30~~70℃ or 0~~50℃ 207 +* Humidity Measuring Range: 0~100%RH(Non-condensing state) 208 +* Accuracy: ±0.2℃ (@25℃); ±3%RH (10%~90%) 209 +* Repeatability: ±0.1℃; ±0.1%RH 210 +* Long-term stability: <0.04℃/year; <0.5%RH/year 211 +* Output signal:RS485 (standard Modbus-RTU protocol) 212 +* Response time: <1s 213 +* Working Environment: Temperature: -55℃~120℃; Humidity: ≤95%RH 209 209 210 210 216 +== 5.2 Wiring == 211 211 212 212 219 +[[image:image-20250505140636-11.png||height="419" width="794"]] 220 + 221 +== 5.3 Mechinical Drawing == 222 + 223 + 224 +[[image:1746425244897-496.png||height="363" width="684"]] 225 + 226 + 227 += 6. WSS-24 Rain and snow sensor = 228 + 229 +== 6.1 Overview and Spec == 230 + 231 +[[image:image-20250505140953-12.png||height="293" width="246"]] 232 + 233 + 234 +* Supply voltage: 12~~24V DC 235 +* Measurement parameters: Rain or snow 236 +* Working temperature: -30~70℃; humidity: 10~90%RH 237 +* Storage temperature: -40~80℃; humidity: 10~90%RH 238 +* Output signal: RS485 (standard Modbus-RTU protocol) 239 +* Stability and response time: <1 second 240 + 241 + 242 +== 6.2 Wiring == 243 + 244 + 245 +[[image:image-20250505144810-14.png]] 246 + 247 +== 6.3 Mechinical Drawing == 248 + 249 +[[image:image-20250505144906-15.png]] 250 + 251 + 252 +== 6.4 Installation Angle Requirements == 253 + 254 +During installation, the sensor sensing surface should be kept at a 15-degree angle to the horizontal plane to prevent rain and snow accumulation from affecting sensor measurement. 255 + 256 +[[image:image-20250505145005-16.png]] 257 + 258 + 259 +7. 260 + 261 + 262 + 213 213
- image-20250505144810-14.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +291.7 KB - Content
- image-20250505144906-15.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +206.6 KB - Content
- image-20250505145005-16.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +154.5 KB - Content