Wiki source code of

Version 81.7 by Mengting Qiu on 2025/07/01 14:02

Show last authors
1 **Table of Contents:**
2
3 {{toc/}}
4
5
6 = 1. WSS-09 ~-~- 9 in 1 Weather Station Sensor =
7
8 == 1.1 Overview and Spec ==
9
10
11 **Older versions of interfaces  New version of the interface**
12
13 [[image:image-20250507141942-2.jpeg]] [[image:image-20250507141229-1.png||height="265" width="205"]]
14
15 **Power Input**: 10 ~~ 30VDC
16
17 **Max Power Consumption**: 1.2W
18
19 **Wind Speed:**
20
21 * Range: 0~~60m/s
22 * Accuracy: ±(0.2m/s±0.02*v)(v : the wind speed)
23 * Ultrasonic measurement,no start wind strength needed
24
25 **Wind Direction:**
26
27 * Range: 0~~3599
28 * Accuracy: ±3°
29 * Ultrasonic measurement, no start wind strength needed
30 * Built-in electronic compass. No need to consider installation direction
31
32 **Temperature:**
33
34 * Range: -40°C ~~ +80°C
35 * Accuracy: ±0.5°C
36
37 **Humidity:**
38
39 * Range: 0 ~~ 99% RH
40 * Accuracy Tolerance : Typ ±3% RH
41
42 **Air Pressure:**
43
44 * Accuracy: ±0.15kPa@25°C 101kPa
45 * Range: 0~~120kPa
46
47 **Noise:**
48
49 * Range: 30dB~~120dB
50 * Accuracy: ±0.5dB
51
52 **PM2.5:**
53
54 * Range: 0~~1000ug/m3
55 * Accuracy: ±3%FS
56 * Resolution: 1ug/m3
57
58 **PM10:**
59
60 * Range: 0~~1000ug/m3
61 * Accuracy: ±3%FS
62 * Resolution: 1ug/m3
63
64 **llumination:**
65
66 * Range: 0~~200k Lux
67 * Accuracy: ±7%(25 °C)
68
69 == 1.2 Wiring ==
70
71 === 1.2.1 Older version wiring ===
72
73 [[image:image-20240714104450-1.png||height="239" width="445"]]
74
75
76 === 1.2.2 New version wiring ===
77
78 [[image:image-20250507161616-1.png||height="363" width="682"]]
79
80
81 == 1.3 Mechinical Drawing ==
82
83
84 (% class="lead" %)
85 **Device Dimension**
86
87 [[image:image-20240714165651-5.png||height="308" width="245"]]
88
89
90 (% class="lead" %)
91 **Installation**
92
93 * Make sure the device is horizontal installed
94 * Device include electronic compass. No need to consider installation direction to get correct wind direction.
95
96 = 2. WSS-08 ~-~- Optical Range Guage =
97
98 == 2.1 Overview and Spec ==
99
100
101 **Older versions of interfaces  New version of the interface**
102
103 [[image:image-20250507142027-3.jpeg]] [[image:image-20250505190822-2.png||height="155" width="197"]]
104
105 * Input Power: 9~~30 VDC
106 * Sense diameter: 6cm
107 * Pulse Output, each pulse , 0.1mm
108 * Max rain: 24mm/min
109 * Operation Temperature: -40 ~~ 60 °C
110 * Operation Humidify: 0~~99%RH(no dew)
111
112 == 2.2 Wiring ==
113
114 === 2.2.1 Older version wiring ===
115
116 [[image:image-20241127091433-1.jpeg||height="361" width="517"]]
117
118
119 === 2.2.2 New version wiring ===
120
121
122 [[image:image-20250505193511-9.png||height="392" width="708"]]
123
124 == 2.3 Mechinical Drawing ==
125
126
127 (% class="lead" %)
128 **Device Dimension**
129
130 [[image:image-20240714164433-1.png||height="211" width="548"]]
131
132
133 (% class="lead" %)
134 **Bracket Dimension**
135
136 [[image:image-20240714164803-3.png||height="306" width="836"]]
137
138
139 (% class="lead" %)
140 **Install without Bracket**
141
142 [[image:image-20240714164856-4.png||height="250" width="433"]]
143
144
145 = 3. WSS-27 ~-~- PAR (Photosynthetically Available Radiation) =
146
147
148 WSS-27 photosynthetically active radiation sensor is mainly used to measure the photosynthetically active radiation of natural light in the wavelength range of 400-700nm.
149
150 WSS-27 use precision optical detectors and has an optical filter of 400-700nm, when natural light is irradiated, a voltage signal proportional to the intensity of the incident radiation is generated, and its luminous flux density is proportional to the cosine of the direct angle of the incident light.
151
152
153 == 3.1 Specification ==
154
155 [[image:1746411474621-748.png||height="175" width="224"]]
156
157 * Input Power: DC 5 ~~ 24v
158 * Interface: RS485
159 * Response Spectrum: 400~~700nm
160 * Measure range: 0 ~~ 2500μmol/m2•s
161 * Resolution: 1μmol/m2•s
162 * Accuracy: ±2%
163 * Yearly Stability: ≤ ±2%
164 * Working Temperature: -30℃ ~~ 75℃
165 * Working Humidity: 10 ~~ 90%RH
166 * Power Consumption: 5mA @ 12v  &  6mA @ 5v
167 * Stable Time: 5s
168
169 == 3.2 Wiring ==
170
171 [[image:image-20250505193330-8.png||height="393" width="744"]]
172
173 == 3.3 Dimension ==
174
175 [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/Dragino%20LoRaWAN%20Weather%20Station%20User%20Manual/WebHome/1656057538793-888.png?rev=1.1||alt="1656057538793-888.png"]]
176
177 == 3.4 Installation Notice ==
178
179
180 Do not power on while connect the cables. Double check the wiring before power on.
181
182 [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/Dragino%20LoRaWAN%20Weather%20Station%20User%20Manual/WebHome/1656057557191-895.png?rev=1.1||alt="1656057557191-895.png"]]
183
184 [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/Dragino%20LoRaWAN%20Weather%20Station%20User%20Manual/WebHome/1656057565783-251.png?rev=1.1||alt="1656057565783-251.png"]]
185
186
187 = 4. WSS-26 ~-~- Total Solar Radiation sensor =
188
189
190 WSS-26 is Total Radiation Sensor can be used to measure the total solar radiation in the spectral range of 0.3 to 3 μm (300 to 3000 nm). If the sensor face is down, the reflected radiation can be measured, and the shading ring can also be used to measure the scattered radiation.
191
192 The core device of the radiation sensor is a high-precision photosensitive element, which has good stability and high precision; at the same time, a precision-machined PTTE radiation cover is installed outside the sensing element, which effectively prevents environmental factors from affecting its performance.
193
194
195 == 4.1 Feature ==
196
197
198 * RS485 Total Solar Radiation sensor
199 * Measure Total Radiation between 0.3 ~~ 3μm(300 ~~ 3000nm)
200 * Measure Reflected Radiation if sense area towards ground.
201
202 == 4.2 Specification ==
203
204
205 (% id="cke_bm_101984S" style="display:none" %)
206
207 * Input Power: DC 5 ~~ 24v
208 * Interface: RS485
209 * Detect spectrum: 0.3 ~~ 3μm(300~3000nm)
210 * Measure strength range: 0 ~~ 2000W/m2
211 * Resolution: 0.1W/m2
212 * Accuracy: ±3%
213 * Yearly Stability: ≤±2%
214 * Cosine response: ≤7% (@ Sun angle 10°)
215 * Temperature Effect: ±2% (-10℃ ~~ 40℃)
216 * Working Temperature: -40℃ ~~ 70℃
217 * Working Humidity: 10 ~~ 90%RH
218 * Power Consumption: 4mA @ 12v
219
220 == 4.3 Wiring ==
221
222
223 [[image:image-20250505193313-7.png||height="391" width="722"]]
224
225 == 4.4 Device Dimension ==
226
227 [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/Dragino%20LoRaWAN%20Weather%20Station%20User%20Manual/WebHome/1656057348695-898.png?rev=1.1||alt="1656057348695-898.png"]]
228
229
230 == 4.5 Installation Notice ==
231
232
233 Do not power on while connect the cables. Double check the wiring before power on.
234
235 [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/Dragino%20LoRaWAN%20Weather%20Station%20User%20Manual/WebHome/1656057369259-804.png?rev=1.1||alt="1656057369259-804.png"]]
236
237 [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/Dragino%20LoRaWAN%20Weather%20Station%20User%20Manual/WebHome/1656057377943-564.png?rev=1.1||alt="1656057377943-564.png"]]
238
239
240 == 4.6 Calibration Values (K-value Adjustment) ==
241
242 In the event of deviations in the sensor values, calibration can be carried out by modifying the sensor's internal parameter: K-value parameter(**Default: 03E8(H)=1000(D)**).
243
244 (% style="color:#037691" %)**Calibration Principle**
245
246 The K-value scales the sensor's output. If multiple sensors measure the same parameter but show different values, adjust the K-value of the secondary sensor(s) to match the primary sensor's reading.
247
248 (% style="color:#037691" %)**Step-by-Step Example:**
249
250 **Scenario:**
251
252 * Sensor 1 (reference) reads 1500.
253 * Sensor 2 reads 2000, but should match Sensor 1's value (~~1500).
254
255 **Steps:**
256
257 1. (((
258 **Calculate the K-value ratio**:
259
260 Ratio=Desired Value
261 )))
262 1. Current Value=15002000=0.75Ratio=Current ValueDesired Value​=20001500​=0.75(((
263 Multiply by the default K-value (1000) to get the new K-value:
264
265 0.75×1000=750(Decimal)0.75×1000=750(Decimal)
266 )))
267
268
269
270
271
272 if the value of sensor 1 is 1500 and the value of sensor 2 is 2000, it is necessary to keep the values around 1500if the value of sensor 1 is 1500 and the value of sensor 2 is 2000, it is necessary to keep the values around 1500.
273
274 Modify the K value of sensor 2:
275
276 * K value calculation as follows:
277 * 1500/2000=0.75,  0.75*1000=750
278 * Convert 750 to hexadecimal to 02EE.
279 * Send command to sensor 2
280 * Send:0B 06 00 53 02 EE F8 5D  Send successfully and return this command
281
282
283
284
285 = 5. WSS-25 ~-~- Temperature, Humidity, Illuminance, Pressure =
286
287
288 WSS-25 is a 4 in 1 RS485 sensor which can monitor Temperature, Humidity, Illuminance and Pressure at the same time.
289
290
291 == 5.1 Feature ==
292
293
294 * RS485 Temperature, Humidity, Illuminance, Pressure sensor
295
296 == 5.2 Specification ==
297
298
299 * Input Power: DC 12 ~~ 24v
300 * Interface: RS485
301 * Temperature Sensor Spec:
302 ** Range: -30 ~~ 70℃
303 ** resolution 0.1℃
304 ** Accuracy: ±0.5℃
305 * Humidity Sensor Spec:
306 ** Range: 0 ~~ 100% RH
307 ** resolution 0.1 %RH
308 ** Accuracy: ±3% RH
309 * Pressure Sensor Spec:
310 ** Range: 10 ~~ 1100hPa
311 ** Resolution: 0.1hPa
312 ** Accuracy: ±0.1hPa
313 * Illuminate sensor:
314 ** Range: 0~~2/20/200kLux
315 ** Resolution: 10 Lux
316 ** Accuracy: ±3%FS
317 * Working Temperature: -30℃ ~~ 70℃
318 * Working Humidity: 10 ~~ 90%RH
319 * Power Consumption: 4mA @ 12v
320
321 == 5.3 Wiring ==
322
323
324 [[image:image-20250505193252-6.png||height="409" width="765"]]
325
326 == 5.4 Dimension ==
327
328
329 [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/Dragino%20LoRaWAN%20Weather%20Station%20User%20Manual/WebHome/1656057170639-522.png?rev=1.1||alt="1656057170639-522.png"]]
330
331
332 == 5.5 Installation Notice ==
333
334
335 Do not power on while connect the cables. Double check the wiring before power on.
336
337 [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/Dragino%20LoRaWAN%20Weather%20Station%20User%20Manual/WebHome/1656057199955-514.png?rev=1.1||alt="1656057199955-514.png"]]
338
339 [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/Dragino%20LoRaWAN%20Weather%20Station%20User%20Manual/WebHome/1656057212438-475.png?rev=1.1||alt="1656057212438-475.png"]]
340
341
342 = 6. WSS-24 ~-~- Rain/Snow Detect =
343
344
345 WSS-24 is a RS485 rain / snow detect sensor. It can monitor Rain or Snow event.
346
347 WSS-24 has auto heating feature, this ensures measurement more reliable.
348
349 == 6.1  Feature ==
350
351
352 * RS485 Rain/Snow detect sensor
353 * Surface heating to dry
354 * grid electrode uses Electroless Nickel/Immersion Gold design for resist corrosion
355
356 == 6.2 Specification ==
357
358
359 * Detect if there is rain or snow
360 * Input Power: DC 12 ~~ 24v
361 * Interface: RS485
362 * Working Temperature: -30℃ ~~ 70℃
363 * Working Humidity: 10 ~~ 90%RH
364 * Power Consumption:
365 ** No heating: 12mA @ 12v,
366 ** heating: 94ma @ 12v.
367
368 == 6.3 Wiring ==
369
370 [[image:image-20250505193053-5.png||height="479" width="895"]]
371
372 == 6.4 Dimension ==
373
374 [[image:image-20250505144906-15.png]]
375
376
377 == 6.5 Installation Notice ==
378
379
380 Do not power on while connect the cables. Double check the wiring before power on.
381
382 Install with 15°degree.
383
384 [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/Dragino%20LoRaWAN%20Weather%20Station%20User%20Manual/WebHome/1656056873783-780.png?rev=1.1||alt="1656056873783-780.png"]]
385
386 [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/Dragino%20LoRaWAN%20Weather%20Station%20User%20Manual/WebHome/1656056883736-804.png?rev=1.1||alt="1656056883736-804.png"]]
387
388 == 6.6 Heating ==
389
390
391 WSS-24 supports auto-heat feature. When the temperature is below the heat start temperature 15℃, WSS-24 starts to heat and stop at stop temperature (default is 25℃).
392
393
394 = 7. WSS-23 ~-~- CO2/PM2.5/PM10 =
395
396
397 WSS-23 is a RS485 Air Quality sensor. It can monitor CO2, PM2.5 and PM10 at the same time.
398
399 WSS-23 uses weather proof shield which can make sure the sensors are well protected against UV & radiation.
400
401
402 == 7.1 Feature ==
403
404
405 * RS485 CO2, PM2.5, PM10 sensor
406 * NDIR to measure CO2 with Internal Temperature Compensation
407 * Laser Beam Scattering to PM2.5 and PM10
408
409 == 7.2  Specification ==
410
411
412 * CO2 Range: 0 ~~ 5000ppm, accuracy: ±3%F•S(25℃)
413 * CO2 resolution: 1ppm
414 * PM2.5/PM10 Range: 0 ~~ 1000μg/m3 , accuracy ±3%F•S(25℃)
415 * PM2.5/PM10 resolution: 1μg/m3
416 * Input Power: DC 7 ~~ 24v
417 * Preheat time: 3min
418 * Interface: RS485
419 * Working Temperature:
420 ** CO2: 0℃ ~~ 50℃;
421 ** PM2.5/PM10: -30 ~~ 50℃
422 * Working Humidity:
423 ** PM2.5/PM10: 15 ~~ 80%RH (no dewing)
424 ** CO2: 0 ~~ 95%RH
425 * Power Consumption: 50mA@ 12v.
426
427 == 7.3 Wiring ==
428
429 [[image:image-20250505193033-4.png||height="376" width="689"]]
430
431 == 7.4 Device Dimension ==
432
433
434 [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/Dragino%20LoRaWAN%20Weather%20Station%20User%20Manual/WebHome/1656056708366-230.png?rev=1.1||alt="1656056708366-230.png"]]
435
436
437 == 7.5 Installation Notice ==
438
439
440 Do not power on while connect the cables. Double check the wiring before power on.
441
442 [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/Dragino%20LoRaWAN%20Weather%20Station%20User%20Manual/WebHome/1656056751153-304.png?rev=1.1||alt="1656056751153-304.png"]]
443
444 [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/Dragino%20LoRaWAN%20Weather%20Station%20User%20Manual/WebHome/1656056766224-773.png?rev=1.1||alt="1656056766224-773.png"]]
445
446
447 = 8. WSS-22 ~-~- Integrated wind speed and direction sensor =
448
449 [[image:1746441120854-584.png||height="271" width="394"]]
450
451 WSS-22 is a RS485 wind speed and wind direction monitor designed for weather station solution.
452
453 WSS-22 shell is made of polycarbonate composite material, which has good anti-corrosion and anti-corrosion characteristics, and ensure the long-term use of the sensor without rust. At the same time, it cooperates with the internal smooth bearing system to ensure the stability of information collection
454
455
456 == 8.1 Feature ==
457
458
459 * RS485 wind speed / direction sensor
460 * PC enclosure, resist corrosion
461
462 == 8.2 Specification ==
463
464
465 * Wind speed range: 0 ~~ 60m/s
466 * Wind direction range: 0 ~~ 360°
467 * Start wind speed: ≤0.3 m/s
468 * Accuracy: ±(0.3+0.03V) m/s , ±1°
469 * Input Power: DC 5 ~~ 24v
470 * Interface: RS485
471 * Working Temperature: -30℃ ~~ 70℃
472 * Working Humidity: <100% (no dewing)
473 * Power Consumption: 13mA @ 12v.
474 * Cable Length: 2 meters
475
476 == 8.3 Wiring ==
477
478 [[image:image-20250505192929-2.png||height="314" width="590"]]
479
480
481 == 8.4 Device Dimension ==
482
483 (% class="wikigeneratedid" %)
484 [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/Dragino%20LoRaWAN%20Weather%20Station%20User%20Manual/WebHome/image-20220624152813-2.png?rev=1.1||alt="image-20220624152813-2.png"]]
485
486
487 == 8.5 Angle Mapping ==
488
489 [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/Dragino%20LoRaWAN%20Weather%20Station%20User%20Manual/WebHome/1656056303845-585.png?rev=1.1||alt="1656056303845-585.png" height="455" width="476"]]
490
491
492 == 8.6 Installation Notice ==
493
494
495 Do not power on while connect the cables. Double check the wiring before power on.
496
497 The sensor must be installed with below direction, towards North.
498
499 [[image:1746441560175-162.png||height="304" width="484"]]
500
501
502 = 9. WSS-21 ~-~- Rain Gauge =
503
504
505 WSS-21 RS485 Rain Gauge is used in meteorology and hydrology to gather and measure the amount of liquid precipitation (mainly rainfall) over an area.
506
507 WSS-21 uses a tipping bucket to detect rainfall. The tipping bucket use 3D streamline shape to make sure it works smoothly and is easy to clean.
508
509 The tipping bucket of WSS-01 is adjusted to the best angle. When installation, user only needs to screw up and adjust the bottom horizontally.
510
511 WSS-21 package includes screw which can be installed to ground. If user want to install WSS-21 on pole, they can purchase WS-K2 bracket kit.
512
513
514 == 9.1 Feature ==
515
516
517 * RS485 Rain Gauge
518 * Small dimension, easy to install
519 * Vents under funnel, avoid leaf or other things to avoid rain flow.
520 * ABS enclosure.
521 * Horizontal adjustable.
522
523 == 9.2  Specification ==
524
525
526 * Resolution: 0.2mm
527 * Accuracy: ±3%
528 * Range: 0 ~~ 100mm
529 * Rainfall strength: 0mm ~~ 4mm/min (max 8mm/min)
530 * Input Power: DC 5 ~~ 24v
531 * Interface: RS485
532 * Working Temperature: 0℃ ~~ 70℃ (incorrect below 0 degree, because water become ICE)
533 * Working Humidity: <100% (no dewing)
534 * Power Consumption: 4mA @ 12v.
535
536 == 9.3 Wiring ==
537
538 [[image:image-20250505192952-3.png||height="305" width="581"]]
539
540
541 == 9.4 Dimension ==
542
543
544 [[image:image-20250505184528-20.png||height="468" width="471"]]
545
546 [[image:image-20250505185334-22.png||height="533" width="470"]]
547
548 == 9.5 Installation Notice ==
549
550
551 (((
552 Do not power on while connect the cables. Double check the wiring before power on.
553 )))
554
555 (((
556 Installation Photo as reference:
557 )))
558
559
560 (((
561 (% style="color:#4472c4" %)** Install on Ground:**
562 )))
563
564 (((
565 WSS-21 Rain Gauge include screws so can install in ground directly .
566 )))
567
568
569 (((
570 (% style="color:#4472c4" %)** Install on pole:**
571 )))
572
573 (((
574 If user want to install on pole, they can purchase the (% style="color:#4472c4" %)** WS-K2 :  Bracket Kit for Pole installation**(%%), and install as below:
575
576 [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/Dragino%20LoRaWAN%20Weather%20Station%20User%20Manual/WebHome/image-20220624152218-1.png?width=276&height=526&rev=1.1||alt="image-20220624152218-1.png"]]
577
578 WS-K2: Bracket Kit for Pole installation
579
580 WSSC-K2 dimension document, please see:
581 )))
582
583 [[https:~~/~~/www.dropbox.com/sh/7wa2elfm2q8xq4l/AAB7ZB_gSVGrhmJEgU2LyTQNa?dl=0>>https://www.dropbox.com/sh/7wa2elfm2q8xq4l/AAB7ZB_gSVGrhmJEgU2LyTQNa?dl=0]]
584
585
586