Table of Contents:

1. WSS-09 9 in 1 Weather Station Sensor

1.1 Overview and Spec

image-20240708092247-1.png

Power Input: 10 ~ 30VDC

Max Power Consumption: 1.2W

Wind Speed:

  • Range: 0~60m/s
  • Accuracy: ±(0.2m/s±0.02*v)(v : the wind speed)
  • Ultrasonic measurement,no start wind strength needed

Wind Direction:

  • Range: 0~3599
  • Accuracy: +3°
  • Ultrasonic measurement,no start wind strength needed
  • Built-in electronic compass. No need to consider installation direction

Temperature:

  • Range: -40°C ~ +80°C
  • Accuracy: +0.5°C

Humidity:

  • Range: 0 ~ 99% RH
  • Accuracy Tolerance : Typ +3% RH

Air Pressure:

  • Accuracy: ±0.15kPa@25°C 101kPa
  • Range: 0~120kPa

Noise:

  • Range: 30dB~120dB
  • Accuracy: +0.5dB

PM2.5:

  • Range: 0~1000ug/m3
  • Accuracy: ±3%FS
  • Resolution: 1ug/m3

PM10:

  • Range: 0~1000ug/m3
  • Accuracy: +3%FS
  • Resolution: 1ug/m3

llumination:

  • Range: 0~200k Lux
  • Accuracy: +7%(25 °C)

1.2 Wiring

1.2.1 Older version wiring

image-20240714104450-1.png

1.2.2 New version wiring

image-20250505102835-7.png

1.3 Mechinical Drawing

Device Dimension

image-20240714165651-5.png

Installation

  • Make sure the device is horizontal installed
  • Device include electronic compass. No need to consider installation direction to get correct wind direction.

2. WSS-08 Optical Range Guage

2.1 Overview and Spec

image-20240707215336-2.png

  • Input Power: 9~30 VDC
  • Sense diameter: 6cm
  • Pulse Output, each pulse , 0.1mm
  • Max rain: 24mm/min
  • Operation Temperature: -40 ~ 60 °C
  • Operation Humidify: 0~99%RH(no dew)

2.2 Wiring

2.2.1 Older version wiring

image-20241127091433-1.jpeg

2.2.2 New version wiring

image-20250505101405-5.png

2.3 Mechinical Drawing

Device Dimension

image-20240714164433-1.png

Bracket Dimension

image-20240714164803-3.png

Install without Bracket

image-20240714164856-4.png

3. WSS-27 Photosynthetically Active Radiation Sensor

3.1 Overview and Spec

1746411474621-748.png

  • Input Power: 5~24V DC
  • Measuring range: 0~2500μmol/m2·s
  • Response time: <1S
  • Resolution: 1μmol/m2·s
  • Accuracy: ±2%
  • Response spectrum: 400~700nm
  • Output signal: RS485 (standard Modbus-RTU protocol)
  • Stability: change within one year <±2%
  • Working environment: -30℃~75℃
  • Impedance requirements for current signals

         image-20250505102448-6.png

3.2 Wiring

image-20250505102905-9.png

3.3 Mechinical Drawing

1746412191614-581.png

 