1.1 | 11 | |
![]() |
15.1 | 12 | === **1.1.1 What is Actility Thingpark Enterprise** === |
![]() |
1.1 | 13 | |
14 | |||
![]() |
15.1 | 15 | //ThingPark Enterprise is an IoT connectivity management solution allowing to the deployment of a dedicated and fully controlled LoRaWAN® network for a fast use case enablement. All components of the network, including sensors, gateways, and data routing are managed from a unique and easy-to-use user interface. The ThingPark Enterprise allows full flexibility in the choice of gateways or devices. It is also a flexible, scalable, and secure solution allowing to start with a Proof-of-Concept (POC) and scale to full deployments.// |
![]() |
1.1 | 16 | |
17 | |||
![]() |
15.1 | 18 | = **2. Gateway Registration for Basics Station** = |
![]() |
1.1 | 19 | |
![]() |
15.1 | 20 | == **2.1 Introduction** == |
21 | |||
22 | |||
23 | //The LoRa Basics™ Station protocol simplifies the management of large-scale LoRaWAN networks. [[The LoRa Basics Station doc>>url:https://www.thethingsindustries.com/docs/gateways/lora-basics-station/]]// | ||
24 | |||
25 | |||
![]() |
40.2 | 26 | (% style="color:blue" %)**Below list the support products and Requirements:** |
![]() |
1.1 | 27 | |
![]() |
15.1 | 28 | 1. //LoRaWAN Gateway model: [[LIG16>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/171-lig16.html]], [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]], [[DLOS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/160-dlos8.html]] [[LPS8>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/148-lps8.html]]// |
29 | 1. //Firmware version since:[[lgw~~-~~-build-v5.4.1651822913>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LPS8/Firmware/Test_Firmware/lgw--build-v5.4.1651822913-20220506-1543/]]// | ||
![]() |
1.1 | 30 | |
![]() |
40.2 | 31 | (% style="color:blue" %)**What do you need to prepare** |
![]() |
1.1 | 32 | |
![]() |
15.1 | 33 | //A gateway that can access the internet normally// |
![]() |
1.1 | 34 | |
35 | |||
![]() |
15.1 | 36 | == **2.2 Step 1. Add Gateway** == |
37 | |||
![]() |
40.2 | 38 | |
![]() |
35.2 | 39 | [[image:image-20220531084235-1.png||height="767" width="1332"]] |
![]() |
1.1 | 40 | |
![]() |
1.2 | 41 | |
![]() |
40.2 | 42 | (% style="color:blue" %)**The following items need to be configured:** |
![]() |
1.2 | 43 | |
![]() |
1.4 | 44 | (% class="box" %) |
45 | ((( | ||
![]() |
15.1 | 46 | // 1.Model **~-~->** Choose the Model |
47 | 2.Name **~-~->** Custom | ||
![]() |
40.1 | 48 | 3.LRR-UUID **~-~->** **0016C0(aways is it)**-Gateway EUI // |
![]() |
15.1 | 49 | |
50 | // Such as: **0016C0-A840411E96744150**// | ||
51 | // 4.RF Region **~-~->** Choose the frequency// | ||
![]() |
1.4 | 52 | ))) |
![]() |
1.2 | 53 | |
![]() |
38.1 | 54 | [[image:image-20220610095043-1.png]] |
![]() |
1.2 | 55 | |
56 | |||
![]() |
40.2 | 57 | (% style="color:blue" %)**//Have need to put in latitude and longitude, and then click "CREATE".//** |
![]() |
15.1 | 58 | |
![]() |
36.2 | 59 | [[image:image-20220531085325-12.png]] |
![]() |
1.2 | 60 | |
61 | |||
![]() |
40.2 | 62 | |
![]() |
15.1 | 63 | == **2.3 Step 2. Access the gateway GUI** == |
![]() |
1.2 | 64 | |
![]() |
40.2 | 65 | |
![]() |
15.1 | 66 | //Users need to update the API key and install the Certificate// |
67 | |||
68 | |||
![]() |
36.3 | 69 | [[image:image-20220531084451-4.png||height="683" width="1357"]] |
![]() |
1.2 | 70 | |
71 | |||
![]() |
40.2 | 72 | |
![]() |
15.1 | 73 | == **2.4 Step 3. Configure Station** == |
![]() |
1.2 | 74 | |
![]() |
40.2 | 75 | |
![]() |
15.1 | 76 | //Users need to input Server URI, as well as install the CUPS certificate.// |
![]() |
1.2 | 77 | |
![]() |
15.1 | 78 | |
![]() |
40.3 | 79 | (% style="color:blue" %)**Just to clarify.** |
![]() |
15.1 | 80 | |
![]() |
1.4 | 81 | (% class="box" %) |
82 | ((( | ||
![]() |
39.1 | 83 | //CUPS Server URI **~-~->** Server Address// |
![]() |
15.1 | 84 | |
85 | // Such as:[[https:~~/~~/community.thingpark.io:443>>url:https://community.thingpark.io/||style="background-color: rgb(250, 250, 250);"]]// | ||
86 | |||
87 | //CUPS certificate **~-~->** server certificate **(user can use the button to install the certificate by default)**// | ||
![]() |
1.4 | 88 | ))) |
![]() |
1.2 | 89 | |
![]() |
36.3 | 90 | [[image:image-20220531084527-5.png||height="685" width="1370"]] |
![]() |
1.2 | 91 | |
92 | Configure the gateway | ||
93 | |||
94 | |||
![]() |
15.1 | 95 | == **2.5 Start Station** == |
![]() |
1.2 | 96 | |
![]() |
40.2 | 97 | |
![]() |
15.1 | 98 | //When the user has finished the configuration, Please click Sace&Apply to start station to connect Actility Thingpark Enterprise.// |
![]() |
1.2 | 99 | |
![]() |
23.8 | 100 | |
![]() |
15.1 | 101 | == **2.6 Successful Connection** == |
![]() |
1.2 | 102 | |
![]() |
40.2 | 103 | |
![]() |
15.1 | 104 | //If users complete the above steps, which will see the live date in the Actility Thingpark Enterprise.// |
105 | |||
106 | |||
![]() |
36.4 | 107 | [[image:image-20220531084632-6.png||height="700" width="1403"]] |
![]() |
1.2 | 108 | |
109 | |||
![]() |
40.2 | 110 | |
![]() |
15.1 | 111 | //Station live date// |
112 | |||
![]() |
36.4 | 113 | [[image:image-20220531084747-7.png||height="591" width="1410"]] |
![]() |
1.2 | 114 | |
115 | |||
![]() |
40.2 | 116 | |
![]() |
15.1 | 117 | == **2.7 Trouble Shooting** == |
![]() |
1.2 | 118 | |
![]() |
40.2 | 119 | |
![]() |
45.1 | 120 | === **2.7.1 How do users view Basic Station logs and Record logs** === |
121 | |||
![]() |
15.1 | 122 | //Users can check the station log on the logread/system log page.// |
123 | |||
124 | |||
125 | //Station Log~:// | ||
126 | |||
![]() |
33.2 | 127 | [[image:image-20220531085014-10.png]] |
![]() |
1.2 | 128 | |
129 | |||
![]() |
40.2 | 130 | |
![]() |
15.1 | 131 | //and recode the station log on the system/Recode log page.// |
![]() |
1.2 | 132 | |
![]() |
32.2 | 133 | [[image:image-20220531084931-9.png]] |
![]() |
1.2 | 134 | |
![]() |
15.1 | 135 | //Recore Log// |
![]() |
1.2 | 136 | |
![]() |
23.11 | 137 | |
![]() |
45.1 | 138 | === **2.7.2 How to solve the problem when "(400) TC credentials not found" is displayed in the log** === |
![]() |
40.2 | 139 | |
![]() |
45.1 | 140 | |
141 | In this case, the user needs to check whether the Gateway ID matches the UUID on Actility Thingpark. | ||
142 | |||
![]() |
46.1 | 143 | In addition, the user needs to regenerate new certificates in ThingPark GUI **(Advanced tab of the Base Station panel)**, Then wait 2-3 minutes to refresh the ThingPark GUI to see if the gateway is online. |
![]() |
45.1 | 144 | |
145 | [[image:image-20220822085416-2.png]] | ||
146 | |||
147 | [[image:image-20220822091137-3.png]] | ||
148 | |||
149 | [[image:image-20220822091229-4.png||height="569" width="1267"]] | ||
150 | |||
151 | |||
![]() |
1.5 | 152 | ((( |
![]() |
40.2 | 153 | //The reason of fail to join Actility is that our end node use (% style="color:blue" %)**RX2DR=3**(%%) for join. this is the default setting for TTN and many LoRaWAN servers.// |
![]() |
1.5 | 154 | ))) |
![]() |
1.2 | 155 | |
![]() |
1.5 | 156 | ((( |
![]() |
40.2 | 157 | //The Actility use (% style="color:blue" %)**RX2DR=0**(%%) for Join, when Actility sends a Join Accept, due to RX2DR different, the end node can not receive the Join Accept message from Actility so keep joining.// |
![]() |
1.5 | 158 | ))) |
![]() |