14
15 = 1. Overview =
16
17 AIS is a video photo recognition sensor, the sensor can be used in electricity meters, gas meters, water meters, pressure gauges and other types of meters. Accurately identify the number of the current dial or upload the picture of the current dial for comparison, which can replace people to go to the door to read the meter, and is more accurate and energy-saving than the meter. The first thing to do is to fix the AIS sensor, the end direction needs to be aligned with the object that needs to be identified, you can check whether the object all appears in the lens range through the upper computer, and then calibrate, Chapter 2 will explain the calibration method of different tables. 
18
19 = 2. Calibrate Digits Readings =
20
21
22 == 2.1 Calibrate a Water Meter ==
23
24 === 2.1.1 Introduce ===
25
26 This water meter is designed in accordance with the Chinese standard for drinking cold water meters and hot water meters, GB/T 778.1-2007. It features five dial numbers for measurement accuracy.
27
28 === 2.1.2 Fix Sensor to a Water Meter ===
29
30 The assembly necessitates the use of two screws, two spacers, and this specific device. Additionally, there are AIS Sensors available along with TTL adapters for AIS Sensors.
31
32 The fixture below is just a demo, user might adjust it with their water meter. Here is the STEP file for the fixture as below: [[Water Meter Fixture Demo>>https://www.dropbox.com/scl/fo/p1ykgysrv8p454swsh4zj/AHCYr5pcOM0WNad4fT1sf_I?rlkey=7x964q1tuvh0ezbhgxb9b2zqg&st=wxxq87t3&dl=0]].
33
34 [[image:image-20240428163842-3.png||height="425" width="609"]] [[image:image-20240428155254-1.png||height="424" width="358"]]
35
36 The procedure is as follows:
37
38 ~1. Secure back of the AIS sensor  onto the small board and adjust its position according to your requirements. You may use two additional screws for fixation or utilize 3M double-sided adhesive for attachment.
39
40 [[image:image-20240428165320-4.gif]]
41
42 2. Proceed by fastening the device using the previously prepared screws and gaskets.
43
44 [[image:image-20240428165354-5.gif]]
45
46 3. Finally, nestle the device onto your water meter, ensuring that it can be adjusted to meet your specific needs while guaranteeing that the camera is directed towards the digital wheel face.
47
48 [[image:image-20240428165412-6.gif]].
49
50 The AI Sensors and AUC USB TTL Adapter for AIS Sensors are connected and then connected to the PC.
51
52 [[image:image-20240428165634-7.gif]][[image:image-20240428165645-8.jpeg||height="332" width="443"]]
53
54
55
56
57 === 2.1.3 Calibration ===
58
59 Launch [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
60
61 Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14.
62
63 (% class="box warningmessage" %)
64 (((
65 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the [[visualcppredist_aio_x6_x64_v42.exe>>https://www.dropbox.com/scl/fi/mzqx6ld5a4zkcecntqjjg/VisualCppRedist_AIO_x86_x64_v42.rar?rlkey=9fuzodmed1fg9ulquh22h0dtr&st=ph6ozi4d&dl=0]] configuration environment. Otherwise, an error pop-up window occurs when running software.
66 )))
67
68 (% aria-label="1713519971789-213.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713519971789-213.png||data-widget="image"]](% title="Click and drag to resize" %)​
69
70 Next, select a Baud rate of 921600 and click on "start". Then, click on "show full image" to display the camera screen.
71
72 (% aria-label="image-20240419174908-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174908-5.png||data-widget="image" height="491" width="406"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​(% aria-label="image-20240419175103-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419175103-7.png||data-widget="image" height="489" width="632"]](% title="Click and drag to resize" %)​
73
74 Click "enable Raw" and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
75
76 (% aria-label="image-20240419175324-8.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419175324-8.png||data-widget="image" height="637" width="911"]](% title="Click and drag to resize" %)​
77
78 (% aria-label="image-20240419175324-9.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419175324-9.png||data-widget="image" height="348" width="913"]](% title="Click and drag to resize" %)​
79
80 This water meter has only five fields, and the coordinates of the digital roulette wheel are shown in the figure.
81
82 If your device's digital scroll wheel dial does not match these five fields, you can try the other field dial coordinate dot plots in 2.4.
83
84 (% aria-label="1713573839396-314.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713573839396-314.png||data-widget="image" height="198" width="649"]](% title="Click and drag to resize" %)​
85
86 The computer's drawing tool can be used to open the latest bmp image and get the coordinates of the digital wheel dial, as shown below. Based on the format of the digital wheel dial, we can obtain each coordinate point of the current use dial. The (x,y) coordinate on the image is located at the bottom left corner.
87
88 (% aria-label="1713574859715-722.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713574859715-722.png||data-widget="image" height="481" width="576"]](% title="Click and drag to resize" %)​
89
90 Click the "ROI setting" button in "HIMAX_AMR_PC_Tool" and three options will pop up
91
92 The "Long dial" option is the long hand dial.
93
94 The "Short dial" option is the short pointer and digital wheel dial.
95
96 The "Digit wheel" option is the digital wheel dial.
97
98 Now we are calibrating the digital wheel face of the water meter. Here we select "digit wheel".
99
100 (% aria-label="1713576691266-408.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713576691266-408.png||data-widget="image"]](% title="Click and drag to resize" %)​
101
102 1:Fill in the coordinates you just got; it's best to get a coordinate and fill in a coordinate.
103
104 2: Fill in the number of number wheel on their dial,fi;
105
106 3: Select the number of short Pointers (currently we don't use short Pointers, the "digit wheelu" option defaults to 0);
107
108 4: Preview whether the setting of their coordinates is accurate;
109
110 5: Click to write all configuration to AIS;
111
112 6: Click the exit configuration interface, at this time, there will be a readout. If the Reading of "reading" is consistent with the watch face, the calibration is successful. The AIS cannot move thereafter to avoid misreading.
113
114 (% aria-label="1713576930301-479.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713576930301-479.png||data-widget="image"]](% title="Click and drag to resize" %)​
115
116 The effect can be previewed by clicking the "Preview correction" button as shown below.
117
118 (% aria-label="1713577029535-253.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713577029535-253.png||data-widget="image" height="748" width="1069"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
119
120
121 After the calibration process is completed, it can be observed that the obtained reading aligns consistently with the numerical value displayed on the digital wheel dial.
122
123 (% aria-label="1713577072196-132.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713577072196-132.png||data-widget="image" height="751" width="1073"]]
124
125 (% title="Click and drag to resize" %)​
126
127 == 2.2 Calibration Power Meter ==
128
129 === 2.2.1 Introduce ===
130
131 This power meter is designed in accordance with the Chinese standard for Electricity metering equipment, GB/T 17215.321-2008. It features six dial numbers for measurement accuracy.
132
133 === 2.2.2 Fix Sensor to a Power Meter(% title="Click and drag to resize" %)​(%%) ===
134
135 You can utilize a couple of pea clips or other suitable fixtures to securely fasten the AIS sensor and ensure precise alignment of the camera with the digital watch wheel.
136
137 [[image:image-20240428180114-11.png||height="705" width="536"]]
138
139 === 2.2.3 Calibration ===
140
141 Perform a power reset on the EVB board, making sure to close the ota.exe program before opening HMX_FT4222H_GUI.exe.
142
143 Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14.
144
145 (% class="box warningmessage" %)
146 (((
147 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the visualcppredist_aio_x6_x64_v42.exe configuration environment. Otherwise, an error pop-up window occurs when running software.
148 )))
149
150 (% aria-label="1713519971789-213.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713519971789-213.png||data-widget="image"]](% title="Click and drag to resize" %)​
151
152 Next, select a Baud rate of 921600 and click on "start". Then, click on "show full image" to display the camera screen.
153
154 (% aria-label="image-20240419174908-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174908-5.png||data-widget="image" height="491" width="406"]][[image:image-20240420135207-3.png||height="485" width="706"]]
155
156 Click "enable Raw" and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
157
158 [[image:1713592384928-500.png||height="494" width="266"]][[image:image-20240420141955-4.png||height="492" width="782"]]
159
160 This power meter has only six fields, and the coordinates of the digital roulette wheel are shown in the figure.
161
162 If your device's digital scroll wheel dial does not match these six fields, you can try the other field dial coordinate dot plots in 2.4.
163
164 (% aria-label="image-20240420094632-13.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-13.png||data-widget="image" height="148" width="588"]]
165
166 The computer's drawing tool can be used to open the latest bmp image and get the coordinates of the digital wheel dial, as shown below. Based on the format of the digital wheel dial, we can obtain each coordinate point of the current use dial. The (x,y) coordinate on the image is located at the bottom left corner.
167
168 [[image:image-20240420153316-11.png||height="569" width="755"]]
169
170 (% id="cke_bm_67462S" style="display:none" %) (%%)Click the "ROI setting" button in "HIMAX_AMR_PC_Tool" and three options will pop up
171
172 The "Long dial" option is the long hand dial.
173
174 The "Short dial" option is the short pointer and digital wheel dial.
175
176 The "Digit wheel" option is the digital wheel dial.
177
178 Now we are calibrating the digital wheel face of the power meter. Here we select "digit wheel".
179
180 (% aria-label="1713576691266-408.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713576691266-408.png||data-widget="image"]](% title="Click and drag to resize" %)​
181
182 1: Fill in the coordinates you just got; it's best to get a coordinate and fill in a coordinate.
183
184 2: Fill in the number of number wheel on their dial,six;
185
186 3: Select the number of short Pointers (currently we don't use short Pointers, the "digit wheelu" option defaults to 0);
187
188 4: Preview whether the setting of their coordinates is accurate;
189
190 5: Click to write all configuration to AIS;
191
192 6: Click the exit configuration interface, at this time, there will be a readout. If the Reading of "reading" is consistent with the watch face, the calibration is successful. The AIS cannot move thereafter to avoid misreading.
193
194 [[image:image-20240420143939-6.png||height="408" width="886"]](% title="Click and drag to resize" %)​
195
196 The effect can be previewed by clicking the "Preview correction" button as shown below.
197
198 [[image:image-20240420144154-7.png||height="534" width="880"]]
199
200 After the calibration process is completed, it can be observed that the obtained reading aligns consistently with the numerical value displayed on the digital wheel dial.
201
202 [[image:1713595371004-125.png]]
203
204
205 == 2.3 Calibration Gas Meter ==
206
207 === 2.3.1 Introduce ===
208
209 This gas meter uses G2.5 membrane gas meter. It features eight dial numbers for measurement accuracy.
210
211 === 2.3.2 Fix Sensor to a Gas Meter ===
212
213 You can utilize a couple of pea clips or other suitable fixtures to securely fasten the AIS sensor and ensure precise alignment of the camera with the digital watch wheel.
214
215 [[image:image-20240428180208-12.png||height="599" width="449"]]
216
217
218 === 2.3.3 Calibration ===
219
220 Perform a power reset on the EVB board, making sure to close the ota.exe program before opening HMX_FT4222H_GUI.exe.
221
222 Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14.
223
224 (% class="box warningmessage" %)
225 (((
226 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the visualcppredist_aio_x6_x64_v42.exe configuration environment. Otherwise, an error pop-up window occurs when running software.
227 )))
228
229 (% aria-label="1713519971789-213.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713519971789-213.png||data-widget="image"]](% title="Click and drag to resize" %)​
230
231 Next, select a Baud rate of 921600 and click on "start". Then, click on "show full image" to display the camera screen.
232
233 (% aria-label="image-20240419174908-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174908-5.png||data-widget="image" height="491" width="406"]][[image:1713598021017-402.png]]
234
235 Click "enable Raw" and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
236
237 [[image:1713592384928-500.png||height="494" width="266"]][[image:1713598094208-496.png||height="494" width="790"]]
238
239 This gas meter has eight fields, and the coordinates of the digital roulette wheel are shown in the figure.
240
241 If your device's digital scroll wheel dial does not match these eight fields, you can try the other field dial coordinate dot plots in 2.4.
242
243 (% aria-label="image-20240420094632-15.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-15.png||data-widget="image" height="113" width="542"]]
244
245 (% id="cke_bm_196694S" style="display:none" %) (%%)The computer's drawing tool can be used to open the latest bmp image and get the coordinates of the digital wheel dial, as shown below. Based on the format of the digital wheel dial, we can obtain each coordinate point of the current use dial. The (x,y) coordinate on the image is located at the bottom left corner.
246
247 [[image:image-20240420153139-10.png||height="530" width="710"]]
248
249 (% id="cke_bm_67462S" style="display:none" %) (%%)Click the "ROI setting" button in "HIMAX_AMR_PC_Tool" and three options will pop up
250
251 The "Long dial" option is the long hand dial.
252
253 The "Short dial" option is the short pointer and digital wheel dial.
254
255 The "Digit wheel" option is the digital wheel dial.
256
257 Now we are calibrating the digital wheel face of the gas meter. Here we select "digit wheel".
258
259 (% aria-label="1713576691266-408.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713576691266-408.png||data-widget="image"]]
260
261 1: Fill in the coordinates you just got; it's best to get a coordinate and fill in a coordinate.
262
263 2: Fill in the number of number wheel on their dial,eight;
264
265 3: Select the number of short Pointers (currently we don't use short Pointers, the "digit wheelu" option defaults to 0);
266
267 4: Preview whether the setting of their coordinates is accurate;
268
269 5: Click to write all configuration to AIS;
270
271 6: Click the exit configuration interface, at this time, there will be a readout. If the Reading of "reading" is consistent with the watch face, the calibration is successful. The AIS cannot move thereafter to avoid misreading.
272
273 [[image:image-20240420154023-12.png||height="436" width="942"]](% title="Click and drag to resize" %)​
274
275 The effect can be previewed by clicking the "Preview correction" button as shown below.
276
277 [[image:1713598855240-454.png]]
278
279 After the calibration process is completed, it can be observed that the obtained reading aligns consistently with the numerical value displayed on the digital wheel dial.
280
281
282 == 2.4 Digital wheel dial take point coordinate diagram ==
283
284 4  numbers:
285
286 (% aria-label="image-20240420094632-11.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-11.png||data-widget="image" height="134" width="410"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
287
288 5 numbers:
289
290 (% aria-label="image-20240420094632-12.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-12.png||data-widget="image" height="130" width="427"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
291
292 6 numbers:
293
294 (% aria-label="image-20240420094632-13.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-13.png||data-widget="image" height="112" width="444"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
295
296 7 numbers:
297
298 (% aria-label="image-20240420094632-14.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-14.png||data-widget="image" height="111" width="454"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
299
300 8 numbers:
301
302 (% aria-label="image-20240420094632-15.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-15.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
303
304
305 = (% title="Click and drag to resize" %)3. Get Sensor Data.(%%) =
306
307 == (% title="Click and drag to resize" %)3.1 Get Digital Reading After Calibration(%%) ==
308
309
310 == (% title="Click and drag to resize" %)3.2 Get Image and show in PC(%%) ==