16
Karry Zhuang 27.1 17 AIS is a video photo recognition sensor, the sensor can be used in electricity meters, gas meters, water meters, pressure gauges and other types of meters. Accurately identify the number of the current dial or upload the picture of the current dial for comparison, which can replace people to go to the door to read the meter, and is more accurate and energy-saving than the meter. The first thing to do is to fix the AIS sensor, the end direction needs to be aligned with the object that needs to be identified, you can check whether the object all appears in the lens range through the upper computer, and then calibrate, Chapter 2 will explain the calibration method of different tables. 
Karry Zhuang 26.1 18
Edwin Chen 1.1 19 = 2. Calibrate Digits Readings =
20
Karry Zhuang 58.2 21
Edwin Chen 1.1 22 == 2.1 Calibrate a Water Meter ==
23
24 === 2.1.1 Introduce ===
25
Karry Zhuang 26.1 26 This water meter is designed in accordance with the Chinese standard for drinking cold water meters and hot water meters, GB/T 778.1-2007. It features five dial numbers for measurement accuracy.
27
Karry Zhuang 90.2 28 === 2.1.2 Fix Sensor to a Water Meter ===
Edwin Chen 1.1 29
Karry Zhuang 90.2 30 The assembly necessitates the use of two screws, two spacers, and this specific device. Additionally, there are AIS Sensors available along with TTL adapters for AIS Sensors.
Edwin Chen 1.1 31
Edwin Chen 81.2 32 The fixture below is just a demo, user might adjust it with their water meter. Here is the STEP file for the fixture as below: [[Water Meter Fixture Demo>>https://www.dropbox.com/scl/fo/p1ykgysrv8p454swsh4zj/AHCYr5pcOM0WNad4fT1sf_I?rlkey=7x964q1tuvh0ezbhgxb9b2zqg&st=wxxq87t3&dl=0]].
33
Karry Zhuang 90.2 34 [[image:image-20240428163842-3.png||height="425" width="609"]] [[image:image-20240428155254-1.png||height="424" width="358"]]
35
36 The procedure is as follows:
37
Karry Zhuang 92.4 38 ~1. Secure back of the AIS sensor  onto the small board and adjust its position according to your requirements. You may use two additional screws for fixation or utilize 3M double-sided adhesive for attachment.
Karry Zhuang 90.2 39
40 [[image:image-20240428165320-4.gif]]
41
42 2. Proceed by fastening the device using the previously prepared screws and gaskets.
43
44 [[image:image-20240428165354-5.gif]]
45
46 3. Finally, nestle the device onto your water meter, ensuring that it can be adjusted to meet your specific needs while guaranteeing that the camera is directed towards the digital wheel face.
47
48 [[image:image-20240428165412-6.gif]].
49
Karry Zhuang 92.2 50 The AI Sensors and AUC USB TTL Adapter for AIS Sensors are connected and then connected to the PC.
Karry Zhuang 90.2 51
Karry Zhuang 92.2 52 [[image:image-20240428165634-7.gif]][[image:image-20240428165645-8.jpeg||height="332" width="443"]]
Karry Zhuang 90.2 53
54
55
56
Karry Zhuang 27.1 57 === 2.1.3 Calibration ===
Karry Zhuang 26.1 58
Karry Zhuang 93.3 59 Launch [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
Karry Zhuang 26.1 60
Karry Zhuang 58.3 61 Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14.
Karry Zhuang 56.5 62
Karry Zhuang 26.1 63 (% class="box warningmessage" %)
64 (((
Karry Zhuang 79.2 65 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the [[visualcppredist_aio_x6_x64_v42.exe>>https://www.dropbox.com/scl/fi/mzqx6ld5a4zkcecntqjjg/VisualCppRedist_AIO_x86_x64_v42.rar?rlkey=9fuzodmed1fg9ulquh22h0dtr&st=ph6ozi4d&dl=0]] configuration environment. Otherwise, an error pop-up window occurs when running software.
Karry Zhuang 26.1 66 )))
67
Karry Zhuang 45.3 68 (% aria-label="1713519971789-213.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713519971789-213.png||data-widget="image"]](% title="Click and drag to resize" %)​
Karry Zhuang 26.1 69
Karry Zhuang 27.1 70 Next, select a Baud rate of 921600 and click on "start". Then, click on "show full image" to display the camera screen.
Karry Zhuang 26.1 71
Karry Zhuang 45.3 72 (% aria-label="image-20240419174908-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174908-5.png||data-widget="image" height="491" width="406"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​(% aria-label="image-20240419175103-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419175103-7.png||data-widget="image" height="489" width="632"]](% title="Click and drag to resize" %)​
Karry Zhuang 26.1 73
Karry Zhuang 27.1 74 Click "enable Raw" and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
Karry Zhuang 26.1 75
Karry Zhuang 45.3 76 (% aria-label="image-20240419175324-8.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419175324-8.png||data-widget="image" height="637" width="911"]](% title="Click and drag to resize" %)​
Karry Zhuang 26.1 77
Karry Zhuang 45.3 78 (% aria-label="image-20240419175324-9.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419175324-9.png||data-widget="image" height="348" width="913"]](% title="Click and drag to resize" %)​
Karry Zhuang 26.1 79
Karry Zhuang 27.1 80 This water meter has only five fields, and the coordinates of the digital roulette wheel are shown in the figure.
Karry Zhuang 26.1 81
Karry Zhuang 27.1 82 If your device's digital scroll wheel dial does not match these five fields, you can try the other field dial coordinate dot plots in 2.4.
Karry Zhuang 26.1 83
Karry Zhuang 45.3 84 (% aria-label="1713573839396-314.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713573839396-314.png||data-widget="image" height="198" width="649"]](% title="Click and drag to resize" %)​
Karry Zhuang 26.1 85
Karry Zhuang 56.3 86 The computer's drawing tool can be used to open the latest bmp image and get the coordinates of the digital wheel dial, as shown below. Based on the format of the digital wheel dial, we can obtain each coordinate point of the current use dial. The (x,y) coordinate on the image is located at the bottom left corner.
Karry Zhuang 26.1 87
Karry Zhuang 45.3 88 (% aria-label="1713574859715-722.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713574859715-722.png||data-widget="image" height="481" width="576"]](% title="Click and drag to resize" %)​
Karry Zhuang 26.1 89
Karry Zhuang 27.1 90 Click the "ROI setting" button in "HIMAX_AMR_PC_Tool" and three options will pop up
Karry Zhuang 29.1 91
Karry Zhuang 27.1 92 The "Long dial" option is the long hand dial.
Karry Zhuang 29.1 93
Karry Zhuang 27.1 94 The "Short dial" option is the short pointer and digital wheel dial.
Karry Zhuang 29.1 95
Karry Zhuang 27.1 96 The "Digit wheel" option is the digital wheel dial.
Karry Zhuang 29.1 97
Karry Zhuang 27.1 98 Now we are calibrating the digital wheel face of the water meter. Here we select "digit wheel".
Karry Zhuang 26.1 99
Karry Zhuang 45.3 100 (% aria-label="1713576691266-408.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713576691266-408.png||data-widget="image"]](% title="Click and drag to resize" %)​
Karry Zhuang 26.1 101
Karry Zhuang 29.1 102 1:Fill in the coordinates you just got; it's best to get a coordinate and fill in a coordinate.
Karry Zhuang 26.1 103
Karry Zhuang 45.2 104 2: Fill in the number of number wheel on their dial,fi;
Karry Zhuang 26.1 105
Karry Zhuang 27.1 106 3: Select the number of short Pointers (currently we don't use short Pointers, the "digit wheelu" option defaults to 0);
Karry Zhuang 26.1 107
Karry Zhuang 27.1 108 4: Preview whether the setting of their coordinates is accurate;
Karry Zhuang 26.1 109
Karry Zhuang 27.1 110 5: Click to write all configuration to AIS;
Karry Zhuang 26.1 111
Karry Zhuang 27.1 112 6: Click the exit configuration interface, at this time, there will be a readout. If the Reading of "reading" is consistent with the watch face, the calibration is successful. The AIS cannot move thereafter to avoid misreading.
Karry Zhuang 26.1 113
Karry Zhuang 45.3 114 (% aria-label="1713576930301-479.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713576930301-479.png||data-widget="image"]](% title="Click and drag to resize" %)​
Karry Zhuang 26.1 115
Karry Zhuang 27.1 116 The effect can be previewed by clicking the "Preview correction" button as shown below.
Karry Zhuang 26.1 117
Karry Zhuang 27.1 118 (% aria-label="1713577029535-253.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713577029535-253.png||data-widget="image" height="748" width="1069"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
Karry Zhuang 26.1 119
120
Karry Zhuang 27.1 121 After the calibration process is completed, it can be observed that the obtained reading aligns consistently with the numerical value displayed on the digital wheel dial.
Karry Zhuang 26.1 122
Karry Zhuang 45.2 123 (% aria-label="1713577072196-132.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713577072196-132.png||data-widget="image" height="751" width="1073"]]
Karry Zhuang 26.1 124
Karry Zhuang 45.2 125 (% title="Click and drag to resize" %)​
126
Karry Zhuang 58.4 127 == 2.2 Calibration Power Meter ==
Karry Zhuang 26.1 128
Karry Zhuang 30.1 129 === 2.2.1 Introduce ===
130
Karry Zhuang 39.2 131 This power meter is designed in accordance with the Chinese standard for Electricity metering equipment, GB/T 17215.321-2008. It features six dial numbers for measurement accuracy.
Karry Zhuang 30.1 132
Karry Zhuang 96.1 133 === 2.2.2 Fix Sensor to a Power Meter(% title="Click and drag to resize" %)​(%%) ===
Karry Zhuang 30.1 134
Karry Zhuang 93.2 135 You can utilize a couple of pea clips or other suitable fixtures to securely fasten the AIS sensor and ensure precise alignment of the camera with the digital watch wheel.
Karry Zhuang 30.1 136
Karry Zhuang 97.2 137 [[image:image-20240428180114-11.png||height="705" width="536"]]
Karry Zhuang 30.1 138
139 === 2.2.3 Calibration ===
140
141 Perform a power reset on the EVB board, making sure to close the ota.exe program before opening HMX_FT4222H_GUI.exe.
142
Karry Zhuang 58.3 143 Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14.
Karry Zhuang 56.5 144
Karry Zhuang 30.1 145 (% class="box warningmessage" %)
146 (((
147 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the visualcppredist_aio_x6_x64_v42.exe configuration environment. Otherwise, an error pop-up window occurs when running software.
148 )))
149
Karry Zhuang 45.2 150 (% aria-label="1713519971789-213.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713519971789-213.png||data-widget="image"]](% title="Click and drag to resize" %)​
Karry Zhuang 30.1 151
152 Next, select a Baud rate of 921600 and click on "start". Then, click on "show full image" to display the camera screen.
153
Karry Zhuang 49.2 154 (% aria-label="image-20240419174908-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174908-5.png||data-widget="image" height="491" width="406"]][[image:image-20240420135207-3.png||height="485" width="706"]]
Karry Zhuang 39.2 155
Karry Zhuang 41.2 156 Click "enable Raw" and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
Karry Zhuang 39.2 157
Karry Zhuang 41.2 158 [[image:1713592384928-500.png||height="494" width="266"]][[image:image-20240420141955-4.png||height="492" width="782"]]
Karry Zhuang 39.2 159
Karry Zhuang 41.2 160 This power meter has only six fields, and the coordinates of the digital roulette wheel are shown in the figure.
Karry Zhuang 39.2 161
Karry Zhuang 41.2 162 If your device's digital scroll wheel dial does not match these six fields, you can try the other field dial coordinate dot plots in 2.4.
Karry Zhuang 39.2 163
Karry Zhuang 41.2 164 (% aria-label="image-20240420094632-13.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-13.png||data-widget="image" height="148" width="588"]]
Karry Zhuang 39.2 165
Karry Zhuang 56.3 166 The computer's drawing tool can be used to open the latest bmp image and get the coordinates of the digital wheel dial, as shown below. Based on the format of the digital wheel dial, we can obtain each coordinate point of the current use dial. The (x,y) coordinate on the image is located at the bottom left corner.
Karry Zhuang 41.2 167
Karry Zhuang 51.2 168 [[image:image-20240420153316-11.png||height="569" width="755"]]
Karry Zhuang 39.2 169
Karry Zhuang 41.3 170 (% id="cke_bm_67462S" style="display:none" %) (%%)Click the "ROI setting" button in "HIMAX_AMR_PC_Tool" and three options will pop up
171
172 The "Long dial" option is the long hand dial.
173
174 The "Short dial" option is the short pointer and digital wheel dial.
175
176 The "Digit wheel" option is the digital wheel dial.
177
178 Now we are calibrating the digital wheel face of the power meter. Here we select "digit wheel".
179
Karry Zhuang 45.3 180 (% aria-label="1713576691266-408.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713576691266-408.png||data-widget="image"]](% title="Click and drag to resize" %)​
Karry Zhuang 41.3 181
182 1: Fill in the coordinates you just got; it's best to get a coordinate and fill in a coordinate.
183
Karry Zhuang 45.2 184 2: Fill in the number of number wheel on their dial,six;
Karry Zhuang 41.3 185
186 3: Select the number of short Pointers (currently we don't use short Pointers, the "digit wheelu" option defaults to 0);
187
188 4: Preview whether the setting of their coordinates is accurate;
189
190 5: Click to write all configuration to AIS;
191
192 6: Click the exit configuration interface, at this time, there will be a readout. If the Reading of "reading" is consistent with the watch face, the calibration is successful. The AIS cannot move thereafter to avoid misreading.
193
Karry Zhuang 45.2 194 [[image:image-20240420143939-6.png||height="408" width="886"]](% title="Click and drag to resize" %)​
Karry Zhuang 41.3 195
196 The effect can be previewed by clicking the "Preview correction" button as shown below.
197
Karry Zhuang 45.2 198 [[image:image-20240420144154-7.png||height="534" width="880"]]
Karry Zhuang 41.3 199
Karry Zhuang 45.2 200 After the calibration process is completed, it can be observed that the obtained reading aligns consistently with the numerical value displayed on the digital wheel dial.
Karry Zhuang 41.3 201
Karry Zhuang 45.2 202 [[image:1713595371004-125.png]]
Karry Zhuang 41.3 203
204
Karry Zhuang 58.4 205 == 2.3 Calibration Gas Meter ==
Karry Zhuang 26.1 206
Karry Zhuang 47.2 207 === 2.3.1 Introduce ===
Karry Zhuang 45.4 208
Karry Zhuang 47.2 209 This gas meter uses G2.5 membrane gas meter. It features eight dial numbers for measurement accuracy.
Karry Zhuang 45.4 210
Karry Zhuang 47.2 211 === 2.3.2 Fix Sensor to a Gas Meter ===
Karry Zhuang 45.4 212
Karry Zhuang 96.1 213 You can utilize a couple of pea clips or other suitable fixtures to securely fasten the AIS sensor and ensure precise alignment of the camera with the digital watch wheel.
Karry Zhuang 45.4 214
Karry Zhuang 99.1 215 [[image:image-20240428180208-12.png||height="599" width="449"]]
Karry Zhuang 45.4 216
Karry Zhuang 99.1 217
Karry Zhuang 62.1 218 === 2.3.3 Calibration ===
Karry Zhuang 47.2 219
220 Perform a power reset on the EVB board, making sure to close the ota.exe program before opening HMX_FT4222H_GUI.exe.
221
Karry Zhuang 58.3 222 Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14.
Karry Zhuang 56.5 223
Karry Zhuang 47.2 224 (% class="box warningmessage" %)
225 (((
226 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the visualcppredist_aio_x6_x64_v42.exe configuration environment. Otherwise, an error pop-up window occurs when running software.
227 )))
228
229 (% aria-label="1713519971789-213.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713519971789-213.png||data-widget="image"]](% title="Click and drag to resize" %)​
230
231 Next, select a Baud rate of 921600 and click on "start". Then, click on "show full image" to display the camera screen.
232
Karry Zhuang 49.2 233 (% aria-label="image-20240419174908-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174908-5.png||data-widget="image" height="491" width="406"]][[image:1713598021017-402.png]]
Karry Zhuang 47.2 234
Karry Zhuang 49.2 235 Click "enable Raw" and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
Karry Zhuang 47.2 236
Karry Zhuang 49.2 237 [[image:1713592384928-500.png||height="494" width="266"]][[image:1713598094208-496.png||height="494" width="790"]]
Karry Zhuang 47.2 238
Karry Zhuang 56.4 239 This gas meter has eight fields, and the coordinates of the digital roulette wheel are shown in the figure.
Karry Zhuang 47.2 240
Karry Zhuang 49.2 241 If your device's digital scroll wheel dial does not match these eight fields, you can try the other field dial coordinate dot plots in 2.4.
Karry Zhuang 47.2 242
Karry Zhuang 49.2 243 (% aria-label="image-20240420094632-15.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-15.png||data-widget="image" height="113" width="542"]]
Karry Zhuang 47.2 244
Karry Zhuang 56.3 245 (% id="cke_bm_196694S" style="display:none" %) (%%)The computer's drawing tool can be used to open the latest bmp image and get the coordinates of the digital wheel dial, as shown below. Based on the format of the digital wheel dial, we can obtain each coordinate point of the current use dial. The (x,y) coordinate on the image is located at the bottom left corner.
Karry Zhuang 47.2 246
Karry Zhuang 50.2 247 [[image:image-20240420153139-10.png||height="530" width="710"]]
Karry Zhuang 49.2 248
Karry Zhuang 50.2 249 (% id="cke_bm_67462S" style="display:none" %) (%%)Click the "ROI setting" button in "HIMAX_AMR_PC_Tool" and three options will pop up
Karry Zhuang 49.2 250
Karry Zhuang 50.2 251 The "Long dial" option is the long hand dial.
Karry Zhuang 49.2 252
Karry Zhuang 50.2 253 The "Short dial" option is the short pointer and digital wheel dial.
254
255 The "Digit wheel" option is the digital wheel dial.
256
Karry Zhuang 56.4 257 Now we are calibrating the digital wheel face of the gas meter. Here we select "digit wheel".
Karry Zhuang 50.2 258
259 (% aria-label="1713576691266-408.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713576691266-408.png||data-widget="image"]]
260
Karry Zhuang 54.2 261 1: Fill in the coordinates you just got; it's best to get a coordinate and fill in a coordinate.
Karry Zhuang 50.2 262
Karry Zhuang 54.2 263 2: Fill in the number of number wheel on their dial,eight;
Karry Zhuang 50.2 264
Karry Zhuang 54.2 265 3: Select the number of short Pointers (currently we don't use short Pointers, the "digit wheelu" option defaults to 0);
Karry Zhuang 50.2 266
Karry Zhuang 54.2 267 4: Preview whether the setting of their coordinates is accurate;
268
269 5: Click to write all configuration to AIS;
270
271 6: Click the exit configuration interface, at this time, there will be a readout. If the Reading of "reading" is consistent with the watch face, the calibration is successful. The AIS cannot move thereafter to avoid misreading.
272
273 [[image:image-20240420154023-12.png||height="436" width="942"]](% title="Click and drag to resize" %)​
274
275 The effect can be previewed by clicking the "Preview correction" button as shown below.
276
277 [[image:1713598855240-454.png]]
278
279 After the calibration process is completed, it can be observed that the obtained reading aligns consistently with the numerical value displayed on the digital wheel dial.
280
281
Karry Zhuang 27.1 282 == 2.4 Digital wheel dial take point coordinate diagram ==
Karry Zhuang 26.1 283
Karry Zhuang 27.1 284 4  numbers:
Karry Zhuang 26.1 285
Karry Zhuang 27.1 286 (% aria-label="image-20240420094632-11.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-11.png||data-widget="image" height="134" width="410"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
Karry Zhuang 26.1 287
Karry Zhuang 27.1 288 5 numbers:
Karry Zhuang 26.1 289
Karry Zhuang 27.1 290 (% aria-label="image-20240420094632-12.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-12.png||data-widget="image" height="130" width="427"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
Karry Zhuang 26.1 291
Karry Zhuang 27.1 292 6 numbers:
Karry Zhuang 26.1 293
Karry Zhuang 27.1 294 (% aria-label="image-20240420094632-13.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-13.png||data-widget="image" height="112" width="444"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
Karry Zhuang 26.1 295
Karry Zhuang 27.1 296 7 numbers:
Karry Zhuang 26.1 297
Karry Zhuang 27.1 298 (% aria-label="image-20240420094632-14.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-14.png||data-widget="image" height="111" width="454"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
Karry Zhuang 26.1 299
Karry Zhuang 27.1 300 8 numbers:
Karry Zhuang 26.1 301
Karry Zhuang 27.1 302 (% aria-label="image-20240420094632-15.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-15.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
Edwin Chen 82.1 303
304
305 = (% title="Click and drag to resize" %)3. Get Sensor Data.(%%) =
306
307 == (% title="Click and drag to resize" %)3.1 Get Digital Reading After Calibration(%%) ==
308