13 = 1. Overview =
14
15
16 AIS is a video photo recognition sensor, the sensor can be used in electricity meters, gas meters, water meters, pressure gauges and other types of meters. Accurately identify the number of the current dial or upload the picture of the current dial for comparison, which can replace people to go to the door to read the meter, and is more accurate and energy-saving than the meter. The first thing to do is to fix the AIS sensor, the end direction needs to be aligned with the object that needs to be identified, you can check whether the object all appears in the lens range through the upper computer, and then calibrate, Chapter 2 will explain the calibration method of different tables. 
17
18
19 = 2. Calibrate Digits Readings =
20
21
22 According to the requirements to upgrade the firmware to correct the reading, respectively:[[Digital wheel dial firmware>>url:https://www.dropbox.com/scl/fi/nxa0nw0k2qhbpcxzfsz03/Digital-table-wheel-firmware.rar?rlkey=u9wqmilfwu899fhc9i2jfcwou&st=ftsl46f5&dl=0]],[[Pointer dial firmware>>url:https://www.dropbox.com/scl/fi/y03feisk7ztq1ey6pmhqb/Pointer-dial-firmware.rar?rlkey=knlx67m1g26xukrthcum1kk23&st=5m196s89&dl=0]].
23
24 Firmware upgrade Reference:[[Update Firmware for the AI Sensors>>http://wiki.dragino.com/xwiki/bin/view/Main/Update%20Firmware%20for%20AI%20Sensor/]].
25
26
27 == 2.1 Calibrate a Water Meter ==
28
29 === 2.1.1 Introduce ===
30
31
32 This water meter is designed in accordance with the Chinese standard for drinking cold water meters and hot water meters, GB/T 778.1-2007. It features five dial numbers for measurement accuracy.
33
34
35 === 2.1.2 Fix Sensor to a Water Meter ===
36
37
38 The assembly necessitates the use of two screws, two spacers, and this specific device.
39
40 Additionally, there are AIS Sensors available along with AUC USB TTL adapters for AIS Sensors.
41
42 The fixture below is just a demo, user might adjust it with their water meter. Here is the STEP file for the fixture as below: [[Water Meter Fixture Demo>>https://www.dropbox.com/scl/fo/p1ykgysrv8p454swsh4zj/AHCYr5pcOM0WNad4fT1sf_I?rlkey=7x964q1tuvh0ezbhgxb9b2zqg&st=wxxq87t3&dl=0]].
43
44 [[image:image-20240428163842-3.png||height="425" width="609"]] [[image:image-20240428155254-1.png||height="424" width="358"]]
45
46 The procedure is as follows:
47
48 ~1. Secure back of the AIS sensor  onto the small board and adjust its position according to your requirements. You may use two additional screws for fixation or utilize 3M double-sided adhesive for attachment.
49
50 [[image:image-20240428165320-4.gif]]
51
52
53 2. Proceed by fastening the device using the previously prepared screws and gaskets.
54
55 [[image:image-20240428165354-5.gif]]
56
57
58 3. Finally, nestle the device onto your water meter, ensuring that it can be adjusted to meet your specific needs while guaranteeing that the camera is directed towards the digital wheel face.
59
60 [[image:image-20240428165412-6.gif]].
61
62
63 The AI Sensors and AUC USB TTL Adapter for AIS Sensors are connected and then connected to the PC.
64
65 [[image:image-20240428165634-7.gif]][[image:image-20240428165645-8.jpeg||height="332" width="443"]]
66
67
68 === 2.1.3 Calibration ===
69
70
71 Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
72
73 For example, Select the corresponding serial port number, here 14.
74
75 (% class="box warningmessage" %)
76 (((
77 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the [[visualcppredist_aio_x6_x64_v42.exe>>https://www.dropbox.com/scl/fi/mzqx6ld5a4zkcecntqjjg/VisualCppRedist_AIO_x86_x64_v42.rar?rlkey=9fuzodmed1fg9ulquh22h0dtr&st=ph6ozi4d&dl=0]] configuration environment. Otherwise, an error pop-up window occurs when running software.
78 )))
79
80 (% aria-label="1713519971789-213.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713519971789-213.png||data-widget="image"]]
81
82 (% title="Click and drag to resize" %)​
83
84 Next, select a Baud rate of **921600** and click on **"start"**. Then, click on **"show full image" **to display the camera screen.
85
86 (% aria-label="image-20240419174908-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174908-5.png||data-widget="image" height="491" width="406"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​(% aria-label="image-20240419175103-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419175103-7.png||data-widget="image" height="489" width="632"]]
87
88 (% title="Click and drag to resize" %)​
89
90 Click **"enable Raw" **and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
91
92 (% aria-label="image-20240419175324-8.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419175324-8.png||data-widget="image" height="637" width="911"]](% title="Click and drag to resize" %)​
93
94 (% aria-label="image-20240419175324-9.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419175324-9.png||data-widget="image" height="348" width="913"]](% title="Click and drag to resize" %)​
95
96 This water meter has only five fields, and the coordinates of the digital roulette wheel are shown in the figure.
97
98 If your device's digital scroll wheel dial does not match these five fields, you can try the other field dial coordinate dot plots in 2.4.
99
100 (% aria-label="1713573839396-314.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713573839396-314.png||data-widget="image" height="198" width="649"]](% title="Click and drag to resize" %)​
101
102 The computer's drawing tool can be used to open the latest bmp image and get the coordinates of the digital wheel dial, as shown below. Based on the format of the digital wheel dial, we can obtain each coordinate point of the current use dial. The (x,y) coordinate on the image is located at the bottom left corner.
103
104 (% aria-label="1713574859715-722.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713574859715-722.png||data-widget="image" height="481" width="576"]]
105
106 (% title="Click and drag to resize" %)​
107
108 Click the "ROI setting" button in "HIMAX_AMR_PC_Tool" and three options will pop up
109
110 The "Long dial" option is the long hand dial.
111
112 The "Short dial" option is the short pointer and digital wheel dial.
113
114 The "Digit wheel" option is the digital wheel dial.
115
116 Now we are calibrating the digital wheel face of the water meter. Here we select "digit wheel".
117
118 (% aria-label="1713576691266-408.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713576691266-408.png||data-widget="image"]](% title="Click and drag to resize" %)​
119
120 1:Fill in the coordinates you just got; it's best to get a coordinate and fill in a coordinate.
121
122 2: Fill in the number of number wheel on their dial,fi;
123
124 3: Select the number of short Pointers (currently we don't use short Pointers, the "digit wheelu" option defaults to 0);
125
126 4: Preview whether the setting of their coordinates is accurate;
127
128 5: Click to write all configuration to AIS;
129
130 6: Click the exit configuration interface, at this time, there will be a readout. If the Reading of "reading" is consistent with the watch face, the calibration is successful. The AIS cannot move thereafter to avoid misreading.
131
132 (% aria-label="1713576930301-479.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713576930301-479.png||data-widget="image"]](% title="Click and drag to resize" %)​
133
134 The effect can be previewed by clicking the "Preview correction" button as shown below.
135
136 (% aria-label="1713577029535-253.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713577029535-253.png||data-widget="image" height="748" width="1069"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
137
138
139 After the calibration process is completed, it can be observed that the obtained reading aligns consistently with the numerical value displayed on the digital wheel dial.
140
141 (% aria-label="1713577072196-132.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713577072196-132.png||data-widget="image" height="751" width="1073"]]
142
143 (% title="Click and drag to resize" %)​
144
145 == 2.2 Calibration Power Meter ==
146
147 === 2.2.1 Introduce ===
148
149
150 This power meter is designed in accordance with the Chinese standard for Electricity metering equipment, GB/T 17215.321-2008. It features six dial numbers for measurement accuracy.
151
152
153 === 2.2.2 Fix Sensor to a Power Meter ===
154
155 (% class="wikigeneratedid" %)
156 === (% title="Click and drag to resize" %)​(%%) ===
157
158 You can utilize a couple of pea clips or other suitable fixtures to securely fasten the AIS sensor and ensure precise alignment of the camera with the digital watch wheel.
159
160 [[image:image-20240429091325-1.png||height="706" width="535"]]
161
162
163 === 2.2.3 Calibration ===
164
165
166 Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
167
168 For example, Select the corresponding serial port number, here 14.
169
170 (% class="box warningmessage" %)
171 (((
172 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the [[visualcppredist_aio_x6_x64_v42.exe>>https://www.dropbox.com/scl/fi/mzqx6ld5a4zkcecntqjjg/VisualCppRedist_AIO_x86_x64_v42.rar?rlkey=9fuzodmed1fg9ulquh22h0dtr&st=ph6ozi4d&dl=0]] configuration environment. Otherwise, an error pop-up window occurs when running software.
173 )))
174
175 (% aria-label="1713519971789-213.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713519971789-213.png||data-widget="image"]]
176
177 (% title="Click and drag to resize" %)​
178
179 Next, select a Baud rate of **921600** and click on **"start"**. Then, click on **"show full image"** to display the camera screen.
180
181 (% aria-label="image-20240419174908-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174908-5.png||data-widget="image" height="491" width="406"]][[image:image-20240420135207-3.png||height="485" width="706"]]
182
183
184 Click **"enable Raw"** and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
185
186 [[image:1713592384928-500.png||height="494" width="266"]][[image:image-20240420141955-4.png||height="492" width="782"]]
187
188 This power meter has only six fields, and the coordinates of the digital roulette wheel are shown in the figure.
189
190 If your device's digital scroll wheel dial does not match these six fields, you can try the other field dial coordinate dot plots in 2.4.
191
192 (% aria-label="image-20240420094632-13.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-13.png||data-widget="image" height="148" width="588"]]
193
194 The computer's drawing tool can be used to open the latest bmp image and get the coordinates of the digital wheel dial, as shown below. Based on the format of the digital wheel dial, we can obtain each coordinate point of the current use dial. The (x,y) coordinate on the image is located at the bottom left corner.
195
196 [[image:image-20240420153316-11.png||height="569" width="755"]]
197
198
199 (% id="cke_bm_67462S" style="display:none" %) (%%)Click the "ROI setting" button in "HIMAX_AMR_PC_Tool" and three options will pop up
200
201 The "Long dial" option is the long hand dial.
202
203 The "Short dial" option is the short pointer and digital wheel dial.
204
205 The "Digit wheel" option is the digital wheel dial.
206
207 Now we are calibrating the digital wheel face of the power meter. Here we select "digit wheel".
208
209 (% aria-label="1713576691266-408.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713576691266-408.png||data-widget="image"]](% title="Click and drag to resize" %)​
210
211 1: Fill in the coordinates you just got; it's best to get a coordinate and fill in a coordinate.
212
213 2: Fill in the number of number wheel on their dial,six;
214
215 3: Select the number of short Pointers (currently we don't use short Pointers, the "digit wheelu" option defaults to 0);
216
217 4: Preview whether the setting of their coordinates is accurate;
218
219 5: Click to write all configuration to AIS;
220
221 6: Click the exit configuration interface, at this time, there will be a readout. If the Reading of "reading" is consistent with the watch face, the calibration is successful. The AIS cannot move thereafter to avoid misreading.
222
223 [[image:image-20240420143939-6.png||height="408" width="886"]](% title="Click and drag to resize" %)​
224
225 The effect can be previewed by clicking the "Preview correction" button as shown below.
226
227 [[image:image-20240420144154-7.png||height="534" width="880"]]
228
229 After the calibration process is completed, it can be observed that the obtained reading aligns consistently with the numerical value displayed on the digital wheel dial.
230
231 [[image:1713595371004-125.png]]
232
233
234 == 2.3 Calibration Gas Meter ==
235
236 === 2.3.1 Introduce ===
237
238
239 This gas meter uses G2.5 membrane gas meter. It features eight dial numbers for measurement accuracy.
240
241
242 === 2.3.2 Fix Sensor to a Gas Meter ===
243
244
245 You can utilize a couple of pea clips or other suitable fixtures to securely fasten the AIS sensor and ensure precise alignment of the camera with the digital watch wheel.
246
247 [[image:image-20240429092436-2.png||height="676" width="519"]]
248
249
250 === 2.3.3 Calibration ===
251
252
253 Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
254
255 For example, Select the corresponding serial port number, here 14.
256
257 (% class="box warningmessage" %)
258 (((
259 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the [[visualcppredist_aio_x6_x64_v42.exe>>https://www.dropbox.com/scl/fi/mzqx6ld5a4zkcecntqjjg/VisualCppRedist_AIO_x86_x64_v42.rar?rlkey=9fuzodmed1fg9ulquh22h0dtr&st=ph6ozi4d&dl=0]] configuration environment. Otherwise, an error pop-up window occurs when running software.
260 )))
261
262 (% aria-label="1713519971789-213.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713519971789-213.png||data-widget="image"]](% title="Click and drag to resize" %)​
263
264 Next, select a Baud rate of 921600 and click on "start". Then, click on "show full image" to display the camera screen.
265
266 (% aria-label="image-20240419174908-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174908-5.png||data-widget="image" height="491" width="406"]][[image:1713598021017-402.png]]
267
268 Click "enable Raw" and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
269
270 [[image:1713592384928-500.png||height="494" width="266"]][[image:1713598094208-496.png||height="494" width="790"]]
271
272 This gas meter has eight fields, and the coordinates of the digital roulette wheel are shown in the figure.
273
274 If your device's digital scroll wheel dial does not match these eight fields, you can try the other field dial coordinate dot plots in 2.4.
275
276 (% aria-label="image-20240420094632-15.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-15.png||data-widget="image" height="113" width="542"]]
277
278 (% id="cke_bm_196694S" style="display:none" %) (%%)The computer's drawing tool can be used to open the latest bmp image and get the coordinates of the digital wheel dial, as shown below. Based on the format of the digital wheel dial, we can obtain each coordinate point of the current use dial. The (x,y) coordinate on the image is located at the bottom left corner.
279
280 [[image:image-20240420153139-10.png||height="530" width="710"]]
281
282 (% id="cke_bm_67462S" style="display:none" %) (%%)Click the "ROI setting" button in "HIMAX_AMR_PC_Tool" and three options will pop up
283
284 The "Long dial" option is the long hand dial.
285
286 The "Short dial" option is the short pointer and digital wheel dial.
287
288 The "Digit wheel" option is the digital wheel dial.
289
290 Now we are calibrating the digital wheel face of the gas meter. Here we select "digit wheel".
291
292 (% aria-label="1713576691266-408.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713576691266-408.png||data-widget="image"]]
293
294 1: Fill in the coordinates you just got; it's best to get a coordinate and fill in a coordinate.
295
296 2: Fill in the number of number wheel on their dial,eight;
297
298 3: Select the number of short Pointers (currently we don't use short Pointers, the "digit wheelu" option defaults to 0);
299
300 4: Preview whether the setting of their coordinates is accurate;
301
302 5: Click to write all configuration to AIS;
303
304 6: Click the exit configuration interface, at this time, there will be a readout. If the Reading of "reading" is consistent with the watch face, the calibration is successful. The AIS cannot move thereafter to avoid misreading.
305
306 [[image:image-20240420154023-12.png||height="436" width="942"]](% title="Click and drag to resize" %)​
307
308 The effect can be previewed by clicking the "Preview correction" button as shown below.
309
310 [[image:1713598855240-454.png]]
311
312 After the calibration process is completed, it can be observed that the obtained reading aligns consistently with the numerical value displayed on the digital wheel dial.
313
314 [[image:1714358288601-933.png]]
315
316
317 == 2.4 Digital wheel dial take point coordinate diagram ==
318
319
320 4  numbers:
321
322 (% aria-label="image-20240420094632-11.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-11.png||data-widget="image" height="134" width="410"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
323
324 5 numbers:
325
326 (% aria-label="image-20240420094632-12.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-12.png||data-widget="image" height="130" width="427"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
327
328 6 numbers:
329
330 (% aria-label="image-20240420094632-13.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-13.png||data-widget="image" height="112" width="444"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
331
332 7 numbers:
333
334 (% aria-label="image-20240420094632-14.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-14.png||data-widget="image" height="111" width="454"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
335
336 8 numbers:
337
338 (% aria-label="image-20240420094632-15.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-15.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]]
339
340 (% title="Click and drag to resize" %)​
341
342 == 2.5 Pressure Pointer Meter Calibration ==
343
344 === 2.5.1 Introduce ===
345
346
347 The pressure pointer meter of the example is 1.6MPa range
348
349
350 === 2.5.2 Fix Sensor to a Power Meter​ ===
351
352
353 You can utilize a couple of pea clips or other suitable fixtures to securely fasten the AIS sensor and ensure precise alignment of the camera with the pressure pointer meter.
354
355 [[image:image-20240516163229-1.jpeg||height="595" width="446"]]
356
357
358 === 2.5.3 Calibration ===
359
360
361 Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
362
363 For example, Select the corresponding serial port number, here 14.
364
365 (% class="box warningmessage" %)
366 (((
367 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the [[visualcppredist_aio_x6_x64_v42.exe>>https://www.dropbox.com/scl/fi/mzqx6ld5a4zkcecntqjjg/VisualCppRedist_AIO_x86_x64_v42.rar?rlkey=9fuzodmed1fg9ulquh22h0dtr&st=ph6ozi4d&dl=0]] configuration environment. Otherwise, an error pop-up window occurs when running software.
368 )))
369
370 [[image:image-20240516163338-2.png||height="455" width="733"]]
371
372
373 Next, select a Baud rate of 921600 and click on "start". Then, click on "show full image" to display the camera screen.
374
375 [[image:image-20240516163423-3.png]]
376
377
378 Click **"enable Raw"** and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
379
380 [[image:image-20240516163501-4.png||height="482" width="694"]]
381
382 [[image:image-20240516163528-5.png||height="336" width="696"]]
383
384
385 The computer's drawing tool can be used to open the latest bmp image and get the coordinates of the pressure pointer meter, as shown below.
386
387 The coordinates of the pressure pointer table are located as shown below.
388
389 1 is the start point, 2 is the center point, and 3 is the end point.
390
391 The (x,y) coordinate on the image is located at the bottom left corner.
392
393 [[image:image-20240516163622-6.png||height="648" width="666"]]
394
395
396 Click on the ROI settingbutton in himax_amr_pc_tool. it will have three optionsThe long dial" option is a long dial dial.The "short dial" option is a short pointer and a number of wheel dial.The digit wheeler option is the digital wheel dial.Now the calibration is the pressure pointer table, which is long dialon."
397
398 [[image:image-20240516163910-7.png]]
399
400
401 Fill in the values of the coordinates you just got, and it's best to get one and write one
402
403 1 Coordinates of the starting point of the scale
404
405 2 Coordinates of the center point of the dial
406
407 3 Coordinates of the end of the scale
408
409 4 Starting scale value
410
411 5 End point scale value *100
412
413 After filling in the data, click "send ROI" to save the Settings and click "Cancel" to exit.
414
415 [[image:image-20240516164128-13.png||height="410" width="889"]]
416
417
418 After the calibration process is completed, The AIS cannot move thereafter to avoid misreading.
419
420 it can be observed that the obtained reading aligns consistently with the numerical value displayed on the digital wheel dial.
421
422 [[image:image-20240516164153-14.png]]
423
424
425 = (% title="Click and drag to resize" %)3. Get Sensor Data.(%%) =
426
427 == (% title="Click and drag to resize" %)3.1 Get Image and show in PC(%%) ==
428
429
430 To get the AIS current image on the PC, you can  connect AIS to your PC with TTL to send commands through the serial port to obtain relevant data packets.
431
432
433 === (% style="color:inherit; font-family:inherit; font-size:23px" %)3.1.1 The image date are obtained by serial port(%%) ===
434
435
436 Select the corresponding baud rate and serial port number through the serial port tool, select HEX display and HEX send, and continuously receive data from the AIS Sensor
437
438 [[image:image-20240514161623-2.png||height="541" width="1439"]]
439
440 In the serial port to send data C0 5A 00 00 00 00 04, and then send C0 5A 00 00 00 00 09, AIS Sensor will send a real-time image of the data packet, and then stop sending. Start with FFD8 and put it in TXT file
441
442 [[image:image-20240514161658-3.png||height="544" width="1441"]]
443
444
445 === 3.1.2 Combined image ===
446
447
448 Once all the data has been uploaded to the TTN platform, the subsequent step involves concatenating each packet in sequential order and saving it into a new TXT file. It is important to note that the first 8 bytes of each packet should be removed before concatenation.
449
450 When you combine all the packets, you need to convert the data inside to binary. Here the conversion is demonstrated using the [[WinHex>>http://www.x-ways.net/winhex/index-m.html]] software.
451
452 Open WinHex to open the combined image data file.
453
454 [[image:1714467040612-103.png||height="134" width="649"]]
455
456
457 Click on the **edit** option to choose and **convert**.
458
459 [[image:1714467065723-178.png||height="349" width="762"]]
460
461
462 Choose the **Hex ASCII->Binary** option and then click OK.
463
464 [[image:1714467089355-837.png||height="366" width="336"]]
465
466
467 After the conversion is finished, click on **"File"** and choose **"Save As"**.
468
469 [[image:1714467112365-676.png]]
470
471
472 Save as **a.jpg file** and click OK to generate a JPG file.
473
474 [[image:1714467126476-110.png]]
475
476
477 Open the saved JPG file to display the image transmitted by the AIS Sensor through the serial port.
478