Wiki source code of AI Image Sensor Calibration

Version 179.1 by Karry Zhuang on 2024/05/16 17:31

Show last authors
1 **Table of Contents:**
2
3 {{toc/}}
4
5
6
7
8
9
10
11
12
13 = 1. Overview =
14
15 AIS is a video photo recognition sensor, the sensor can be used in electricity meters, gas meters, water meters, pressure gauges and other types of meters. Accurately identify the number of the current dial or upload the picture of the current dial for comparison, which can replace people to go to the door to read the meter, and is more accurate and energy-saving than the meter. The first thing to do is to fix the AIS sensor, the end direction needs to be aligned with the object that needs to be identified, you can check whether the object all appears in the lens range through the upper computer, and then calibrate, Chapter 2 will explain the calibration method of different tables. 
16
17 = 2. Calibrate Digits Readings =
18
19 According to the requirements to upgrade the firmware to correct the reading, respectively:[[Digital wheel dial firmware>>url:https://www.dropbox.com/scl/fi/nxa0nw0k2qhbpcxzfsz03/Digital-table-wheel-firmware.rar?rlkey=u9wqmilfwu899fhc9i2jfcwou&st=ftsl46f5&dl=0]],[[Pointer dial firmware>>url:https://www.dropbox.com/scl/fi/y03feisk7ztq1ey6pmhqb/Pointer-dial-firmware.rar?rlkey=knlx67m1g26xukrthcum1kk23&st=5m196s89&dl=0]].
20
21 Firmware upgrade Reference:[[Update Firmware for the AI Sensors>>http://wiki.dragino.com/xwiki/bin/view/Main/Update%20Firmware%20for%20AI%20Sensor/]].
22
23 == 2.1 Calibrate a Water Meter ==
24
25 === 2.1.1 Introduce ===
26
27 This water meter is designed in accordance with the Chinese standard for drinking cold water meters and hot water meters, GB/T 778.1-2007. It features five dial numbers for measurement accuracy.
28
29 === 2.1.2 Fix Sensor to a Water Meter ===
30
31 The assembly necessitates the use of two screws, two spacers, and this specific device.
32
33 Additionally, there are AIS Sensors available along with AUC USB TTL adapters for AIS Sensors.
34
35 The fixture below is just a demo, user might adjust it with their water meter. Here is the STEP file for the fixture as below: [[Water Meter Fixture Demo>>https://www.dropbox.com/scl/fo/p1ykgysrv8p454swsh4zj/AHCYr5pcOM0WNad4fT1sf_I?rlkey=7x964q1tuvh0ezbhgxb9b2zqg&st=wxxq87t3&dl=0]].
36
37 [[image:image-20240428163842-3.png||height="425" width="609"]] [[image:image-20240428155254-1.png||height="424" width="358"]]
38
39 The procedure is as follows:
40
41 ~1. Secure back of the AIS sensor  onto the small board and adjust its position according to your requirements. You may use two additional screws for fixation or utilize 3M double-sided adhesive for attachment.
42
43 [[image:image-20240428165320-4.gif]]
44
45 2. Proceed by fastening the device using the previously prepared screws and gaskets.
46
47 [[image:image-20240428165354-5.gif]]
48
49 3. Finally, nestle the device onto your water meter, ensuring that it can be adjusted to meet your specific needs while guaranteeing that the camera is directed towards the digital wheel face.
50
51 [[image:image-20240428165412-6.gif]].
52
53 The AI Sensors and AUC USB TTL Adapter for AIS Sensors are connected and then connected to the PC.
54
55 [[image:image-20240428165634-7.gif]][[image:image-20240428165645-8.jpeg||height="332" width="443"]]
56
57
58
59
60 === 2.1.3 Calibration ===
61
62 Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
63
64 For example, Select the corresponding serial port number, here 14.
65
66 (% class="box warningmessage" %)
67 (((
68 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the [[visualcppredist_aio_x6_x64_v42.exe>>https://www.dropbox.com/scl/fi/mzqx6ld5a4zkcecntqjjg/VisualCppRedist_AIO_x86_x64_v42.rar?rlkey=9fuzodmed1fg9ulquh22h0dtr&st=ph6ozi4d&dl=0]] configuration environment. Otherwise, an error pop-up window occurs when running software.
69 )))
70
71 (% aria-label="1713519971789-213.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713519971789-213.png||data-widget="image"]](% title="Click and drag to resize" %)​
72
73 Next, select a Baud rate of 921600 and click on "start". Then, click on "show full image" to display the camera screen.
74
75 (% aria-label="image-20240419174908-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174908-5.png||data-widget="image" height="491" width="406"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​(% aria-label="image-20240419175103-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419175103-7.png||data-widget="image" height="489" width="632"]](% title="Click and drag to resize" %)​
76
77 Click "enable Raw" and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
78
79 (% aria-label="image-20240419175324-8.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419175324-8.png||data-widget="image" height="637" width="911"]](% title="Click and drag to resize" %)​
80
81 (% aria-label="image-20240419175324-9.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419175324-9.png||data-widget="image" height="348" width="913"]](% title="Click and drag to resize" %)​
82
83 This water meter has only five fields, and the coordinates of the digital roulette wheel are shown in the figure.
84
85 If your device's digital scroll wheel dial does not match these five fields, you can try the other field dial coordinate dot plots in 2.4.
86
87 (% aria-label="1713573839396-314.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713573839396-314.png||data-widget="image" height="198" width="649"]](% title="Click and drag to resize" %)​
88
89 The computer's drawing tool can be used to open the latest bmp image and get the coordinates of the digital wheel dial, as shown below. Based on the format of the digital wheel dial, we can obtain each coordinate point of the current use dial. The (x,y) coordinate on the image is located at the bottom left corner.
90
91 (% aria-label="1713574859715-722.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713574859715-722.png||data-widget="image" height="481" width="576"]](% title="Click and drag to resize" %)​
92
93 Click the "ROI setting" button in "HIMAX_AMR_PC_Tool" and three options will pop up
94
95 The "Long dial" option is the long hand dial.
96
97 The "Short dial" option is the short pointer and digital wheel dial.
98
99 The "Digit wheel" option is the digital wheel dial.
100
101 Now we are calibrating the digital wheel face of the water meter. Here we select "digit wheel".
102
103 (% aria-label="1713576691266-408.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713576691266-408.png||data-widget="image"]](% title="Click and drag to resize" %)​
104
105 1:Fill in the coordinates you just got; it's best to get a coordinate and fill in a coordinate.
106
107 2: Fill in the number of number wheel on their dial,fi;
108
109 3: Select the number of short Pointers (currently we don't use short Pointers, the "digit wheelu" option defaults to 0);
110
111 4: Preview whether the setting of their coordinates is accurate;
112
113 5: Click to write all configuration to AIS;
114
115 6: Click the exit configuration interface, at this time, there will be a readout. If the Reading of "reading" is consistent with the watch face, the calibration is successful. The AIS cannot move thereafter to avoid misreading.
116
117 (% aria-label="1713576930301-479.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713576930301-479.png||data-widget="image"]](% title="Click and drag to resize" %)​
118
119 The effect can be previewed by clicking the "Preview correction" button as shown below.
120
121 (% aria-label="1713577029535-253.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713577029535-253.png||data-widget="image" height="748" width="1069"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
122
123
124 After the calibration process is completed, it can be observed that the obtained reading aligns consistently with the numerical value displayed on the digital wheel dial.
125
126 (% aria-label="1713577072196-132.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713577072196-132.png||data-widget="image" height="751" width="1073"]]
127
128 (% title="Click and drag to resize" %)​
129
130 == 2.2 Calibration Power Meter ==
131
132 === 2.2.1 Introduce ===
133
134 This power meter is designed in accordance with the Chinese standard for Electricity metering equipment, GB/T 17215.321-2008. It features six dial numbers for measurement accuracy.
135
136 === 2.2.2 Fix Sensor to a Power Meter(% title="Click and drag to resize" %)​(%%) ===
137
138 You can utilize a couple of pea clips or other suitable fixtures to securely fasten the AIS sensor and ensure precise alignment of the camera with the digital watch wheel.
139
140 [[image:image-20240429091325-1.png||height="706" width="535"]]
141
142 === 2.2.3 Calibration ===
143
144 Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
145
146 For example, Select the corresponding serial port number, here 14.
147
148 (% class="box warningmessage" %)
149 (((
150 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the [[visualcppredist_aio_x6_x64_v42.exe>>https://www.dropbox.com/scl/fi/mzqx6ld5a4zkcecntqjjg/VisualCppRedist_AIO_x86_x64_v42.rar?rlkey=9fuzodmed1fg9ulquh22h0dtr&st=ph6ozi4d&dl=0]] configuration environment. Otherwise, an error pop-up window occurs when running software.
151 )))
152
153 (% aria-label="1713519971789-213.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713519971789-213.png||data-widget="image"]](% title="Click and drag to resize" %)​
154
155 Next, select a Baud rate of 921600 and click on "start". Then, click on "show full image" to display the camera screen.
156
157 (% aria-label="image-20240419174908-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174908-5.png||data-widget="image" height="491" width="406"]][[image:image-20240420135207-3.png||height="485" width="706"]]
158
159 Click "enable Raw" and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
160
161 [[image:1713592384928-500.png||height="494" width="266"]][[image:image-20240420141955-4.png||height="492" width="782"]]
162
163 This power meter has only six fields, and the coordinates of the digital roulette wheel are shown in the figure.
164
165 If your device's digital scroll wheel dial does not match these six fields, you can try the other field dial coordinate dot plots in 2.4.
166
167 (% aria-label="image-20240420094632-13.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-13.png||data-widget="image" height="148" width="588"]]
168
169 The computer's drawing tool can be used to open the latest bmp image and get the coordinates of the digital wheel dial, as shown below. Based on the format of the digital wheel dial, we can obtain each coordinate point of the current use dial. The (x,y) coordinate on the image is located at the bottom left corner.
170
171 [[image:image-20240420153316-11.png||height="569" width="755"]]
172
173 (% id="cke_bm_67462S" style="display:none" %) (%%)Click the "ROI setting" button in "HIMAX_AMR_PC_Tool" and three options will pop up
174
175 The "Long dial" option is the long hand dial.
176
177 The "Short dial" option is the short pointer and digital wheel dial.
178
179 The "Digit wheel" option is the digital wheel dial.
180
181 Now we are calibrating the digital wheel face of the power meter. Here we select "digit wheel".
182
183 (% aria-label="1713576691266-408.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713576691266-408.png||data-widget="image"]](% title="Click and drag to resize" %)​
184
185 1: Fill in the coordinates you just got; it's best to get a coordinate and fill in a coordinate.
186
187 2: Fill in the number of number wheel on their dial,six;
188
189 3: Select the number of short Pointers (currently we don't use short Pointers, the "digit wheelu" option defaults to 0);
190
191 4: Preview whether the setting of their coordinates is accurate;
192
193 5: Click to write all configuration to AIS;
194
195 6: Click the exit configuration interface, at this time, there will be a readout. If the Reading of "reading" is consistent with the watch face, the calibration is successful. The AIS cannot move thereafter to avoid misreading.
196
197 [[image:image-20240420143939-6.png||height="408" width="886"]](% title="Click and drag to resize" %)​
198
199 The effect can be previewed by clicking the "Preview correction" button as shown below.
200
201 [[image:image-20240420144154-7.png||height="534" width="880"]]
202
203 After the calibration process is completed, it can be observed that the obtained reading aligns consistently with the numerical value displayed on the digital wheel dial.
204
205 [[image:1713595371004-125.png]]
206
207
208 == 2.3 Calibration Gas Meter ==
209
210 === 2.3.1 Introduce ===
211
212 This gas meter uses G2.5 membrane gas meter. It features eight dial numbers for measurement accuracy.
213
214 === 2.3.2 Fix Sensor to a Gas Meter ===
215
216 You can utilize a couple of pea clips or other suitable fixtures to securely fasten the AIS sensor and ensure precise alignment of the camera with the digital watch wheel.
217
218 [[image:image-20240429092436-2.png||height="676" width="519"]]
219
220
221 === 2.3.3 Calibration ===
222
223 Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
224
225 For example, Select the corresponding serial port number, here 14.
226
227 (% class="box warningmessage" %)
228 (((
229 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the [[visualcppredist_aio_x6_x64_v42.exe>>https://www.dropbox.com/scl/fi/mzqx6ld5a4zkcecntqjjg/VisualCppRedist_AIO_x86_x64_v42.rar?rlkey=9fuzodmed1fg9ulquh22h0dtr&st=ph6ozi4d&dl=0]] configuration environment. Otherwise, an error pop-up window occurs when running software.
230 )))
231
232 (% aria-label="1713519971789-213.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713519971789-213.png||data-widget="image"]](% title="Click and drag to resize" %)​
233
234 Next, select a Baud rate of 921600 and click on "start". Then, click on "show full image" to display the camera screen.
235
236 (% aria-label="image-20240419174908-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174908-5.png||data-widget="image" height="491" width="406"]][[image:1713598021017-402.png]]
237
238 Click "enable Raw" and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
239
240 [[image:1713592384928-500.png||height="494" width="266"]][[image:1713598094208-496.png||height="494" width="790"]]
241
242 This gas meter has eight fields, and the coordinates of the digital roulette wheel are shown in the figure.
243
244 If your device's digital scroll wheel dial does not match these eight fields, you can try the other field dial coordinate dot plots in 2.4.
245
246 (% aria-label="image-20240420094632-15.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-15.png||data-widget="image" height="113" width="542"]]
247
248 (% id="cke_bm_196694S" style="display:none" %) (%%)The computer's drawing tool can be used to open the latest bmp image and get the coordinates of the digital wheel dial, as shown below. Based on the format of the digital wheel dial, we can obtain each coordinate point of the current use dial. The (x,y) coordinate on the image is located at the bottom left corner.
249
250 [[image:image-20240420153139-10.png||height="530" width="710"]]
251
252 (% id="cke_bm_67462S" style="display:none" %) (%%)Click the "ROI setting" button in "HIMAX_AMR_PC_Tool" and three options will pop up
253
254 The "Long dial" option is the long hand dial.
255
256 The "Short dial" option is the short pointer and digital wheel dial.
257
258 The "Digit wheel" option is the digital wheel dial.
259
260 Now we are calibrating the digital wheel face of the gas meter. Here we select "digit wheel".
261
262 (% aria-label="1713576691266-408.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713576691266-408.png||data-widget="image"]]
263
264 1: Fill in the coordinates you just got; it's best to get a coordinate and fill in a coordinate.
265
266 2: Fill in the number of number wheel on their dial,eight;
267
268 3: Select the number of short Pointers (currently we don't use short Pointers, the "digit wheelu" option defaults to 0);
269
270 4: Preview whether the setting of their coordinates is accurate;
271
272 5: Click to write all configuration to AIS;
273
274 6: Click the exit configuration interface, at this time, there will be a readout. If the Reading of "reading" is consistent with the watch face, the calibration is successful. The AIS cannot move thereafter to avoid misreading.
275
276 [[image:image-20240420154023-12.png||height="436" width="942"]](% title="Click and drag to resize" %)​
277
278 The effect can be previewed by clicking the "Preview correction" button as shown below.
279
280 [[image:1713598855240-454.png]]
281
282 After the calibration process is completed, it can be observed that the obtained reading aligns consistently with the numerical value displayed on the digital wheel dial.
283
284 [[image:1714358288601-933.png]]
285
286 == 2.4 Digital wheel dial take point coordinate diagram ==
287
288 4  numbers:
289
290 (% aria-label="image-20240420094632-11.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-11.png||data-widget="image" height="134" width="410"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
291
292 5 numbers:
293
294 (% aria-label="image-20240420094632-12.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-12.png||data-widget="image" height="130" width="427"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
295
296 6 numbers:
297
298 (% aria-label="image-20240420094632-13.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-13.png||data-widget="image" height="112" width="444"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
299
300 7 numbers:
301
302 (% aria-label="image-20240420094632-14.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-14.png||data-widget="image" height="111" width="454"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
303
304 8 numbers:
305
306 (% aria-label="image-20240420094632-15.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-15.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]]
307
308 (% title="Click and drag to resize" %)​
309
310 == 2.5 Pressure Pointer Meter Calibration ==
311
312 === 2.5.1 Introduce ===
313
314 The pressure pointer meter of the example is 1.6MPa range
315
316 === 2.5.2 Fix Sensor to a Power Meter​ ===
317
318 You can utilize a couple of pea clips or other suitable fixtures to securely fasten the AIS sensor and ensure precise alignment of the camera with the pressure pointer meter.
319
320 [[image:image-20240516163229-1.jpeg||height="595" width="446"]]
321
322 === 2.5.3 Calibration ===
323
324 Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
325
326 For example, Select the corresponding serial port number, here 14.
327
328 (% class="box warningmessage" %)
329 (((
330 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the [[visualcppredist_aio_x6_x64_v42.exe>>https://www.dropbox.com/scl/fi/mzqx6ld5a4zkcecntqjjg/VisualCppRedist_AIO_x86_x64_v42.rar?rlkey=9fuzodmed1fg9ulquh22h0dtr&st=ph6ozi4d&dl=0]] configuration environment. Otherwise, an error pop-up window occurs when running software.
331 )))
332
333 [[image:image-20240516163338-2.png||height="455" width="733"]]
334
335
336 Next, select a Baud rate of 921600 and click on "start". Then, click on "show full image" to display the camera screen.
337
338 [[image:image-20240516163423-3.png]]
339
340
341 Click "enable Raw" and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
342
343 [[image:image-20240516163501-4.png||height="482" width="694"]]
344
345 [[image:image-20240516163528-5.png||height="336" width="696"]]
346
347
348 The computer's drawing tool can be used to open the latest bmp image and get the coordinates of the pressure pointer meter, as shown below.
349
350 The coordinates of the pressure pointer table are located as shown below.
351
352 1 is the start point, 2 is the center point, and 3 is the end point.
353
354 The (x,y) coordinate on the image is located at the bottom left corner.
355
356 [[image:image-20240516163622-6.png||height="648" width="666"]]
357
358
359 Click on the ROI settingbutton in himax_amr_pc_tool. it will have three optionsThe long dial" option is a long dial dial.The "short dial" option is a short pointer and a number of wheel dial.The digit wheeler option is the digital wheel dial.Now the calibration is the pressure pointer table, which is long dialon."
360
361 [[image:image-20240516163910-7.png]]
362
363
364 Fill in the values of the coordinates you just got, and it's best to get one and write one
365
366 1 Coordinates of the starting point of the scale
367
368 2 Coordinates of the center point of the dial
369
370 3 Coordinates of the end of the scale
371
372 4 Starting scale value
373
374 5 End point scale value *100
375
376 After filling in the data, click "send ROI" to save the Settings and click "Cancel" to exit.
377
378 [[image:image-20240516164128-13.png||height="410" width="889"]]
379
380
381 After the calibration process is completed, The AIS cannot move thereafter to avoid misreading.
382
383 it can be observed that the obtained reading aligns consistently with the numerical value displayed on the digital wheel dial.
384
385 [[image:image-20240516164153-14.png]]
386
387
388
389 = (% title="Click and drag to resize" %)3. Get Sensor Data.(%%) =
390
391
392 == (% title="Click and drag to resize" %)3.1 Get Image and show in PC(%%) ==
393
394 To get the AIS current image on the PC, you can  connect AIS to your PC with TTL to send commands through the serial port to obtain relevant data packets.
395
396 === (% id="cke_bm_3839S" style="display:none" %) (%%)3.1.1 The image date are obtained by serial port ===
397
398 Select the corresponding baud rate and serial port number through the serial port tool, select HEX display and HEX send, and continuously receive data from the AIS Sensor
399
400 [[image:image-20240514161623-2.png||height="541" width="1439"]]
401
402 In the serial port to send data C0 5A 00 00 00 00 04, and then send C0 5A 00 00 00 00 09, AIS Sensor will send a real-time image of the data packet, and then stop sending. Start with FFD8 and put it in TXT file
403
404 [[image:image-20240514161658-3.png||height="544" width="1441"]]
405
406
407 === 3.1.2 Combined image ===
408
409 Once all the data has been uploaded to the TTN platform, the subsequent step involves concatenating each packet in sequential order and saving it into a new TXT file. It is important to note that the first 8 bytes of each packet should be removed before concatenation.
410
411 When you combine all the packets, you need to convert the data inside to binary. Here the conversion is demonstrated using the [[WinHex>>http://www.x-ways.net/winhex/index-m.html]] software.
412
413 Open WinHex to open the combined image data file.
414
415 [[image:1714467040612-103.png||height="134" width="649"]]
416
417 Click on the edit option to choose and convert.
418
419 [[image:1714467065723-178.png||height="349" width="762"]]
420
421 Choose the Hex ASCII->Binary option and then click OK.
422
423 [[image:1714467089355-837.png||height="366" width="336"]]
424
425 After the conversion is finished, click on "File" and choose "Save As".
426
427 [[image:1714467112365-676.png]]
428
429 Save as a.jpg file and click OK to generate a JPG file.
430
431 [[image:1714467126476-110.png]]
432