Wiki source code of AI Image Sensor Calibration

Version 176.1 by Karry Zhuang on 2024/05/16 16:58

Show last authors
1
2
3
4
5
6 **Table of Contents:**
7
8 {{toc/}}
9
10
11
12
13
14
15 = 1. Overview =
16
17 AIS is a video photo recognition sensor, the sensor can be used in electricity meters, gas meters, water meters, pressure gauges and other types of meters. Accurately identify the number of the current dial or upload the picture of the current dial for comparison, which can replace people to go to the door to read the meter, and is more accurate and energy-saving than the meter. The first thing to do is to fix the AIS sensor, the end direction needs to be aligned with the object that needs to be identified, you can check whether the object all appears in the lens range through the upper computer, and then calibrate, Chapter 2 will explain the calibration method of different tables. 
18
19 = 2. Calibrate Digits Readings =
20
21 According to the requirements to upgrade the firmware to correct the reading, respectively:[[Digital wheel dial firmware>>url:https://www.dropbox.com/scl/fi/nxa0nw0k2qhbpcxzfsz03/Digital-table-wheel-firmware.rar?rlkey=u9wqmilfwu899fhc9i2jfcwou&st=ftsl46f5&dl=0]],[[Pointer dial firmware>>url:https://www.dropbox.com/scl/fi/y03feisk7ztq1ey6pmhqb/Pointer-dial-firmware.rar?rlkey=knlx67m1g26xukrthcum1kk23&st=5m196s89&dl=0]].
22
23 Firmware upgrade Reference:[[Update Firmware for the AI Sensors>>http://wiki.dragino.com/xwiki/bin/view/Main/Update%20Firmware%20for%20AI%20Sensor/]].
24
25 == 2.1 Calibrate a Water Meter ==
26
27 === 2.1.1 Introduce ===
28
29 This water meter is designed in accordance with the Chinese standard for drinking cold water meters and hot water meters, GB/T 778.1-2007. It features five dial numbers for measurement accuracy.
30
31 === 2.1.2 Fix Sensor to a Water Meter ===
32
33 The assembly necessitates the use of two screws, two spacers, and this specific device.
34
35 Additionally, there are AIS Sensors available along with AUC USB TTL adapters for AIS Sensors.
36
37 The fixture below is just a demo, user might adjust it with their water meter. Here is the STEP file for the fixture as below: [[Water Meter Fixture Demo>>https://www.dropbox.com/scl/fo/p1ykgysrv8p454swsh4zj/AHCYr5pcOM0WNad4fT1sf_I?rlkey=7x964q1tuvh0ezbhgxb9b2zqg&st=wxxq87t3&dl=0]].
38
39 [[image:image-20240428163842-3.png||height="425" width="609"]] [[image:image-20240428155254-1.png||height="424" width="358"]]
40
41 The procedure is as follows:
42
43 ~1. Secure back of the AIS sensor  onto the small board and adjust its position according to your requirements. You may use two additional screws for fixation or utilize 3M double-sided adhesive for attachment.
44
45 [[image:image-20240428165320-4.gif]]
46
47 2. Proceed by fastening the device using the previously prepared screws and gaskets.
48
49 [[image:image-20240428165354-5.gif]]
50
51 3. Finally, nestle the device onto your water meter, ensuring that it can be adjusted to meet your specific needs while guaranteeing that the camera is directed towards the digital wheel face.
52
53 [[image:image-20240428165412-6.gif]].
54
55 The AI Sensors and AUC USB TTL Adapter for AIS Sensors are connected and then connected to the PC.
56
57 [[image:image-20240428165634-7.gif]][[image:image-20240428165645-8.jpeg||height="332" width="443"]]
58
59
60
61
62 === 2.1.3 Calibration ===
63
64 Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
65
66 For example, Select the corresponding serial port number, here 14.
67
68 (% class="box warningmessage" %)
69 (((
70 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the [[visualcppredist_aio_x6_x64_v42.exe>>https://www.dropbox.com/scl/fi/mzqx6ld5a4zkcecntqjjg/VisualCppRedist_AIO_x86_x64_v42.rar?rlkey=9fuzodmed1fg9ulquh22h0dtr&st=ph6ozi4d&dl=0]] configuration environment. Otherwise, an error pop-up window occurs when running software.
71 )))
72
73 (% aria-label="1713519971789-213.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713519971789-213.png||data-widget="image"]](% title="Click and drag to resize" %)​
74
75 Next, select a Baud rate of 921600 and click on "start". Then, click on "show full image" to display the camera screen.
76
77 (% aria-label="image-20240419174908-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174908-5.png||data-widget="image" height="491" width="406"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​(% aria-label="image-20240419175103-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419175103-7.png||data-widget="image" height="489" width="632"]](% title="Click and drag to resize" %)​
78
79 Click "enable Raw" and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
80
81 (% aria-label="image-20240419175324-8.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419175324-8.png||data-widget="image" height="637" width="911"]](% title="Click and drag to resize" %)​
82
83 (% aria-label="image-20240419175324-9.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419175324-9.png||data-widget="image" height="348" width="913"]](% title="Click and drag to resize" %)​
84
85 This water meter has only five fields, and the coordinates of the digital roulette wheel are shown in the figure.
86
87 If your device's digital scroll wheel dial does not match these five fields, you can try the other field dial coordinate dot plots in 2.4.
88
89 (% aria-label="1713573839396-314.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713573839396-314.png||data-widget="image" height="198" width="649"]](% title="Click and drag to resize" %)​
90
91 The computer's drawing tool can be used to open the latest bmp image and get the coordinates of the digital wheel dial, as shown below. Based on the format of the digital wheel dial, we can obtain each coordinate point of the current use dial. The (x,y) coordinate on the image is located at the bottom left corner.
92
93 (% aria-label="1713574859715-722.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713574859715-722.png||data-widget="image" height="481" width="576"]](% title="Click and drag to resize" %)​
94
95 Click the "ROI setting" button in "HIMAX_AMR_PC_Tool" and three options will pop up
96
97 The "Long dial" option is the long hand dial.
98
99 The "Short dial" option is the short pointer and digital wheel dial.
100
101 The "Digit wheel" option is the digital wheel dial.
102
103 Now we are calibrating the digital wheel face of the water meter. Here we select "digit wheel".
104
105 (% aria-label="1713576691266-408.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713576691266-408.png||data-widget="image"]](% title="Click and drag to resize" %)​
106
107 1:Fill in the coordinates you just got; it's best to get a coordinate and fill in a coordinate.
108
109 2: Fill in the number of number wheel on their dial,fi;
110
111 3: Select the number of short Pointers (currently we don't use short Pointers, the "digit wheelu" option defaults to 0);
112
113 4: Preview whether the setting of their coordinates is accurate;
114
115 5: Click to write all configuration to AIS;
116
117 6: Click the exit configuration interface, at this time, there will be a readout. If the Reading of "reading" is consistent with the watch face, the calibration is successful. The AIS cannot move thereafter to avoid misreading.
118
119 (% aria-label="1713576930301-479.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713576930301-479.png||data-widget="image"]](% title="Click and drag to resize" %)​
120
121 The effect can be previewed by clicking the "Preview correction" button as shown below.
122
123 (% aria-label="1713577029535-253.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713577029535-253.png||data-widget="image" height="748" width="1069"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
124
125
126 After the calibration process is completed, it can be observed that the obtained reading aligns consistently with the numerical value displayed on the digital wheel dial.
127
128 (% aria-label="1713577072196-132.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713577072196-132.png||data-widget="image" height="751" width="1073"]]
129
130 (% title="Click and drag to resize" %)​
131
132 == 2.2 Calibration Power Meter ==
133
134 === 2.2.1 Introduce ===
135
136 This power meter is designed in accordance with the Chinese standard for Electricity metering equipment, GB/T 17215.321-2008. It features six dial numbers for measurement accuracy.
137
138 === 2.2.2 Fix Sensor to a Power Meter(% title="Click and drag to resize" %)​(%%) ===
139
140 You can utilize a couple of pea clips or other suitable fixtures to securely fasten the AIS sensor and ensure precise alignment of the camera with the digital watch wheel.
141
142 [[image:image-20240429091325-1.png||height="706" width="535"]]
143
144 === 2.2.3 Calibration ===
145
146 Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
147
148 For example, Select the corresponding serial port number, here 14.
149
150 (% class="box warningmessage" %)
151 (((
152 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the [[visualcppredist_aio_x6_x64_v42.exe>>https://www.dropbox.com/scl/fi/mzqx6ld5a4zkcecntqjjg/VisualCppRedist_AIO_x86_x64_v42.rar?rlkey=9fuzodmed1fg9ulquh22h0dtr&st=ph6ozi4d&dl=0]] configuration environment. Otherwise, an error pop-up window occurs when running software.
153 )))
154
155 (% aria-label="1713519971789-213.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713519971789-213.png||data-widget="image"]](% title="Click and drag to resize" %)​
156
157 Next, select a Baud rate of 921600 and click on "start". Then, click on "show full image" to display the camera screen.
158
159 (% aria-label="image-20240419174908-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174908-5.png||data-widget="image" height="491" width="406"]][[image:image-20240420135207-3.png||height="485" width="706"]]
160
161 Click "enable Raw" and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
162
163 [[image:1713592384928-500.png||height="494" width="266"]][[image:image-20240420141955-4.png||height="492" width="782"]]
164
165 This power meter has only six fields, and the coordinates of the digital roulette wheel are shown in the figure.
166
167 If your device's digital scroll wheel dial does not match these six fields, you can try the other field dial coordinate dot plots in 2.4.
168
169 (% aria-label="image-20240420094632-13.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-13.png||data-widget="image" height="148" width="588"]]
170
171 The computer's drawing tool can be used to open the latest bmp image and get the coordinates of the digital wheel dial, as shown below. Based on the format of the digital wheel dial, we can obtain each coordinate point of the current use dial. The (x,y) coordinate on the image is located at the bottom left corner.
172
173 [[image:image-20240420153316-11.png||height="569" width="755"]]
174
175 (% id="cke_bm_67462S" style="display:none" %) (%%)Click the "ROI setting" button in "HIMAX_AMR_PC_Tool" and three options will pop up
176
177 The "Long dial" option is the long hand dial.
178
179 The "Short dial" option is the short pointer and digital wheel dial.
180
181 The "Digit wheel" option is the digital wheel dial.
182
183 Now we are calibrating the digital wheel face of the power meter. Here we select "digit wheel".
184
185 (% aria-label="1713576691266-408.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713576691266-408.png||data-widget="image"]](% title="Click and drag to resize" %)​
186
187 1: Fill in the coordinates you just got; it's best to get a coordinate and fill in a coordinate.
188
189 2: Fill in the number of number wheel on their dial,six;
190
191 3: Select the number of short Pointers (currently we don't use short Pointers, the "digit wheelu" option defaults to 0);
192
193 4: Preview whether the setting of their coordinates is accurate;
194
195 5: Click to write all configuration to AIS;
196
197 6: Click the exit configuration interface, at this time, there will be a readout. If the Reading of "reading" is consistent with the watch face, the calibration is successful. The AIS cannot move thereafter to avoid misreading.
198
199 [[image:image-20240420143939-6.png||height="408" width="886"]](% title="Click and drag to resize" %)​
200
201 The effect can be previewed by clicking the "Preview correction" button as shown below.
202
203 [[image:image-20240420144154-7.png||height="534" width="880"]]
204
205 After the calibration process is completed, it can be observed that the obtained reading aligns consistently with the numerical value displayed on the digital wheel dial.
206
207 [[image:1713595371004-125.png]]
208
209
210 == 2.3 Calibration Gas Meter ==
211
212 === 2.3.1 Introduce ===
213
214 This gas meter uses G2.5 membrane gas meter. It features eight dial numbers for measurement accuracy.
215
216 === 2.3.2 Fix Sensor to a Gas Meter ===
217
218 You can utilize a couple of pea clips or other suitable fixtures to securely fasten the AIS sensor and ensure precise alignment of the camera with the digital watch wheel.
219
220 [[image:image-20240429092436-2.png||height="676" width="519"]]
221
222
223 === 2.3.3 Calibration ===
224
225 Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
226
227 For example, Select the corresponding serial port number, here 14.
228
229 (% class="box warningmessage" %)
230 (((
231 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the [[visualcppredist_aio_x6_x64_v42.exe>>https://www.dropbox.com/scl/fi/mzqx6ld5a4zkcecntqjjg/VisualCppRedist_AIO_x86_x64_v42.rar?rlkey=9fuzodmed1fg9ulquh22h0dtr&st=ph6ozi4d&dl=0]] configuration environment. Otherwise, an error pop-up window occurs when running software.
232 )))
233
234 (% aria-label="1713519971789-213.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713519971789-213.png||data-widget="image"]](% title="Click and drag to resize" %)​
235
236 Next, select a Baud rate of 921600 and click on "start". Then, click on "show full image" to display the camera screen.
237
238 (% aria-label="image-20240419174908-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174908-5.png||data-widget="image" height="491" width="406"]][[image:1713598021017-402.png]]
239
240 Click "enable Raw" and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
241
242 [[image:1713592384928-500.png||height="494" width="266"]][[image:1713598094208-496.png||height="494" width="790"]]
243
244 This gas meter has eight fields, and the coordinates of the digital roulette wheel are shown in the figure.
245
246 If your device's digital scroll wheel dial does not match these eight fields, you can try the other field dial coordinate dot plots in 2.4.
247
248 (% aria-label="image-20240420094632-15.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-15.png||data-widget="image" height="113" width="542"]]
249
250 (% id="cke_bm_196694S" style="display:none" %) (%%)The computer's drawing tool can be used to open the latest bmp image and get the coordinates of the digital wheel dial, as shown below. Based on the format of the digital wheel dial, we can obtain each coordinate point of the current use dial. The (x,y) coordinate on the image is located at the bottom left corner.
251
252 [[image:image-20240420153139-10.png||height="530" width="710"]]
253
254 (% id="cke_bm_67462S" style="display:none" %) (%%)Click the "ROI setting" button in "HIMAX_AMR_PC_Tool" and three options will pop up
255
256 The "Long dial" option is the long hand dial.
257
258 The "Short dial" option is the short pointer and digital wheel dial.
259
260 The "Digit wheel" option is the digital wheel dial.
261
262 Now we are calibrating the digital wheel face of the gas meter. Here we select "digit wheel".
263
264 (% aria-label="1713576691266-408.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713576691266-408.png||data-widget="image"]]
265
266 1: Fill in the coordinates you just got; it's best to get a coordinate and fill in a coordinate.
267
268 2: Fill in the number of number wheel on their dial,eight;
269
270 3: Select the number of short Pointers (currently we don't use short Pointers, the "digit wheelu" option defaults to 0);
271
272 4: Preview whether the setting of their coordinates is accurate;
273
274 5: Click to write all configuration to AIS;
275
276 6: Click the exit configuration interface, at this time, there will be a readout. If the Reading of "reading" is consistent with the watch face, the calibration is successful. The AIS cannot move thereafter to avoid misreading.
277
278 [[image:image-20240420154023-12.png||height="436" width="942"]](% title="Click and drag to resize" %)​
279
280 The effect can be previewed by clicking the "Preview correction" button as shown below.
281
282 [[image:1713598855240-454.png]]
283
284 After the calibration process is completed, it can be observed that the obtained reading aligns consistently with the numerical value displayed on the digital wheel dial.
285
286 [[image:1714358288601-933.png]]
287
288 == 2.4 Digital wheel dial take point coordinate diagram ==
289
290 4  numbers:
291
292 (% aria-label="image-20240420094632-11.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-11.png||data-widget="image" height="134" width="410"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
293
294 5 numbers:
295
296 (% aria-label="image-20240420094632-12.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-12.png||data-widget="image" height="130" width="427"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
297
298 6 numbers:
299
300 (% aria-label="image-20240420094632-13.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-13.png||data-widget="image" height="112" width="444"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
301
302 7 numbers:
303
304 (% aria-label="image-20240420094632-14.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-14.png||data-widget="image" height="111" width="454"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
305
306 8 numbers:
307
308 (% aria-label="image-20240420094632-15.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-15.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]]
309
310 (% title="Click and drag to resize" %)​
311
312 == 2.5 Pressure Pointer Meter Calibration ==
313
314 === 2.5.1 Introduce ===
315
316 The pressure pointer meter of the example is 1.6MPa range
317
318 === 2.5.2 Fix Sensor to a Power Meter​ ===
319
320 You can utilize a couple of pea clips or other suitable fixtures to securely fasten the AIS sensor and ensure precise alignment of the camera with the pressure pointer meter.
321
322 [[image:image-20240516163229-1.jpeg||height="595" width="446"]]
323
324 === 2.5.3 Calibration ===
325
326 Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
327
328 For example, Select the corresponding serial port number, here 14.
329
330 (% class="box warningmessage" %)
331 (((
332 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the [[visualcppredist_aio_x6_x64_v42.exe>>https://www.dropbox.com/scl/fi/mzqx6ld5a4zkcecntqjjg/VisualCppRedist_AIO_x86_x64_v42.rar?rlkey=9fuzodmed1fg9ulquh22h0dtr&st=ph6ozi4d&dl=0]] configuration environment. Otherwise, an error pop-up window occurs when running software.
333 )))
334
335 [[image:image-20240516163338-2.png||height="455" width="733"]]
336
337
338 Next, select a Baud rate of 921600 and click on "start". Then, click on "show full image" to display the camera screen.
339
340 [[image:image-20240516163423-3.png]]
341
342
343 Click "enable Raw" and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
344
345 [[image:image-20240516163501-4.png||height="482" width="694"]]
346
347 [[image:image-20240516163528-5.png||height="336" width="696"]]
348
349
350 The computer's drawing tool can be used to open the latest bmp image and get the coordinates of the pressure pointer meter, as shown below.
351
352 The coordinates of the pressure pointer table are located as shown below.
353
354 1 is the start point, 2 is the center point, and 3 is the end point.
355
356 The (x,y) coordinate on the image is located at the bottom left corner.
357
358 [[image:image-20240516163622-6.png||height="648" width="666"]]
359
360
361 Click on the ROI settingbutton in himax_amr_pc_tool. it will have three optionsThe long dial" option is a long dial dial.The "short dial" option is a short pointer and a number of wheel dial.The digit wheeler option is the digital wheel dial.Now the calibration is the pressure pointer table, which is long dialon."
362
363 [[image:image-20240516163910-7.png]]
364
365
366 Fill in the values of the coordinates you just got, and it's best to get one and write one
367
368 1 Coordinates of the starting point of the scale
369
370 2 Coordinates of the center point of the dial
371
372 3 Coordinates of the end of the scale
373
374 4 Starting scale value
375
376 5 End point scale value *100
377
378 After filling in the data, click "send ROI" to save the Settings and click "Cancel" to exit.
379
380 [[image:image-20240516164128-13.png||height="410" width="889"]]
381
382
383 After the calibration process is completed, The AIS cannot move thereafter to avoid misreading.
384
385 it can be observed that the obtained reading aligns consistently with the numerical value displayed on the digital wheel dial.
386
387 [[image:image-20240516164153-14.png]]
388
389
390
391 = (% title="Click and drag to resize" %)3. Get Sensor Data.(%%) =
392
393
394 == (% title="Click and drag to resize" %)3.1 Get Image and show in PC(%%) ==
395
396 To get the AIS current image on the PC, you can  connect AIS to your PC with TTL to send commands through the serial port to obtain relevant data packets.
397
398 === (% id="cke_bm_3839S" style="display:none" %) (%%)3.1.1 The image date are obtained by serial port ===
399
400 Select the corresponding baud rate and serial port number through the serial port tool, select HEX display and HEX send, and continuously receive data from the AIS Sensor
401
402 [[image:image-20240514161623-2.png||height="541" width="1439"]]
403
404 In the serial port to send data C0 5A 00 00 00 00 04, and then send C0 5A 00 00 00 00 09, AIS Sensor will send a real-time image of the data packet, and then stop sending. Start with FFD8 and put it in TXT file
405
406 [[image:image-20240514161658-3.png||height="544" width="1441"]]
407
408
409 === 3.1.2 Combined image ===
410
411 Once all the data has been uploaded to the TTN platform, the subsequent step involves concatenating each packet in sequential order and saving it into a new TXT file. It is important to note that the first 8 bytes of each packet should be removed before concatenation.
412
413 When you combine all the packets, you need to convert the data inside to binary. Here the conversion is demonstrated using the [[WinHex>>http://www.x-ways.net/winhex/index-m.html]] software.
414
415 Open WinHex to open the combined image data file.
416
417 [[image:1714467040612-103.png||height="134" width="649"]]
418
419 Click on the edit option to choose and convert.
420
421 [[image:1714467065723-178.png||height="349" width="762"]]
422
423 Choose the Hex ASCII->Binary option and then click OK.
424
425 [[image:1714467089355-837.png||height="366" width="336"]]
426
427 After the conversion is finished, click on "File" and choose "Save As".
428
429 [[image:1714467112365-676.png]]
430
431 Save as a.jpg file and click OK to generate a JPG file.
432
433 [[image:1714467126476-110.png]]
434
435 Open the saved JPG file to display the image transmitted by the AIS Sensor through the serial port.
436
437 [[image:1714467134950-189.png]]
438
439 === ===