Wiki source code of AI Image Sensor Calibration

Version 176.1 by Karry Zhuang on 2024/05/16 16:58

Hide last authors
Edwin Chen 3.1 1
Edwin Chen 2.1 2
3
4
Karry Zhuang 28.1 5
Karry Zhuang 60.1 6 **Table of Contents:**
Edwin Chen 2.1 7
Karry Zhuang 60.1 8 {{toc/}}
Edwin Chen 2.1 9
10
11
12
13
Karry Zhuang 60.1 14
Edwin Chen 1.1 15 = 1. Overview =
16
Karry Zhuang 27.1 17 AIS is a video photo recognition sensor, the sensor can be used in electricity meters, gas meters, water meters, pressure gauges and other types of meters. Accurately identify the number of the current dial or upload the picture of the current dial for comparison, which can replace people to go to the door to read the meter, and is more accurate and energy-saving than the meter. The first thing to do is to fix the AIS sensor, the end direction needs to be aligned with the object that needs to be identified, you can check whether the object all appears in the lens range through the upper computer, and then calibrate, Chapter 2 will explain the calibration method of different tables. 
Karry Zhuang 26.1 18
Edwin Chen 1.1 19 = 2. Calibrate Digits Readings =
20
Karry Zhuang 176.1 21 According to the requirements to upgrade the firmware to correct the reading, respectively:[[Digital wheel dial firmware>>url:https://www.dropbox.com/scl/fi/nxa0nw0k2qhbpcxzfsz03/Digital-table-wheel-firmware.rar?rlkey=u9wqmilfwu899fhc9i2jfcwou&st=ftsl46f5&dl=0]],[[Pointer dial firmware>>url:https://www.dropbox.com/scl/fi/y03feisk7ztq1ey6pmhqb/Pointer-dial-firmware.rar?rlkey=knlx67m1g26xukrthcum1kk23&st=5m196s89&dl=0]].
Karry Zhuang 58.2 22
Karry Zhuang 176.1 23 Firmware upgrade Reference:[[Update Firmware for the AI Sensors>>http://wiki.dragino.com/xwiki/bin/view/Main/Update%20Firmware%20for%20AI%20Sensor/]].
24
Edwin Chen 1.1 25 == 2.1 Calibrate a Water Meter ==
26
27 === 2.1.1 Introduce ===
28
Karry Zhuang 26.1 29 This water meter is designed in accordance with the Chinese standard for drinking cold water meters and hot water meters, GB/T 778.1-2007. It features five dial numbers for measurement accuracy.
30
Karry Zhuang 90.2 31 === 2.1.2 Fix Sensor to a Water Meter ===
Edwin Chen 1.1 32
Karry Zhuang 113.1 33 The assembly necessitates the use of two screws, two spacers, and this specific device.
Edwin Chen 1.1 34
Karry Zhuang 113.1 35 Additionally, there are AIS Sensors available along with AUC USB TTL adapters for AIS Sensors.
36
Edwin Chen 81.2 37 The fixture below is just a demo, user might adjust it with their water meter. Here is the STEP file for the fixture as below: [[Water Meter Fixture Demo>>https://www.dropbox.com/scl/fo/p1ykgysrv8p454swsh4zj/AHCYr5pcOM0WNad4fT1sf_I?rlkey=7x964q1tuvh0ezbhgxb9b2zqg&st=wxxq87t3&dl=0]].
38
Karry Zhuang 90.2 39 [[image:image-20240428163842-3.png||height="425" width="609"]] [[image:image-20240428155254-1.png||height="424" width="358"]]
40
41 The procedure is as follows:
42
Karry Zhuang 92.4 43 ~1. Secure back of the AIS sensor  onto the small board and adjust its position according to your requirements. You may use two additional screws for fixation or utilize 3M double-sided adhesive for attachment.
Karry Zhuang 90.2 44
45 [[image:image-20240428165320-4.gif]]
46
47 2. Proceed by fastening the device using the previously prepared screws and gaskets.
48
49 [[image:image-20240428165354-5.gif]]
50
51 3. Finally, nestle the device onto your water meter, ensuring that it can be adjusted to meet your specific needs while guaranteeing that the camera is directed towards the digital wheel face.
52
53 [[image:image-20240428165412-6.gif]].
54
Karry Zhuang 92.2 55 The AI Sensors and AUC USB TTL Adapter for AIS Sensors are connected and then connected to the PC.
Karry Zhuang 90.2 56
Karry Zhuang 92.2 57 [[image:image-20240428165634-7.gif]][[image:image-20240428165645-8.jpeg||height="332" width="443"]]
Karry Zhuang 90.2 58
59
60
61
Karry Zhuang 27.1 62 === 2.1.3 Calibration ===
Karry Zhuang 26.1 63
Karry Zhuang 157.1 64 Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
Karry Zhuang 26.1 65
Karry Zhuang 175.1 66 For example, Select the corresponding serial port number, here 14.
Karry Zhuang 56.5 67
Karry Zhuang 26.1 68 (% class="box warningmessage" %)
69 (((
Karry Zhuang 79.2 70 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the [[visualcppredist_aio_x6_x64_v42.exe>>https://www.dropbox.com/scl/fi/mzqx6ld5a4zkcecntqjjg/VisualCppRedist_AIO_x86_x64_v42.rar?rlkey=9fuzodmed1fg9ulquh22h0dtr&st=ph6ozi4d&dl=0]] configuration environment. Otherwise, an error pop-up window occurs when running software.
Karry Zhuang 26.1 71 )))
72
Karry Zhuang 45.3 73 (% aria-label="1713519971789-213.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713519971789-213.png||data-widget="image"]](% title="Click and drag to resize" %)​
Karry Zhuang 26.1 74
Karry Zhuang 27.1 75 Next, select a Baud rate of 921600 and click on "start". Then, click on "show full image" to display the camera screen.
Karry Zhuang 26.1 76
Karry Zhuang 45.3 77 (% aria-label="image-20240419174908-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174908-5.png||data-widget="image" height="491" width="406"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​(% aria-label="image-20240419175103-7.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419175103-7.png||data-widget="image" height="489" width="632"]](% title="Click and drag to resize" %)​
Karry Zhuang 26.1 78
Karry Zhuang 27.1 79 Click "enable Raw" and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
Karry Zhuang 26.1 80
Karry Zhuang 45.3 81 (% aria-label="image-20240419175324-8.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419175324-8.png||data-widget="image" height="637" width="911"]](% title="Click and drag to resize" %)​
Karry Zhuang 26.1 82
Karry Zhuang 45.3 83 (% aria-label="image-20240419175324-9.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419175324-9.png||data-widget="image" height="348" width="913"]](% title="Click and drag to resize" %)​
Karry Zhuang 26.1 84
Karry Zhuang 27.1 85 This water meter has only five fields, and the coordinates of the digital roulette wheel are shown in the figure.
Karry Zhuang 26.1 86
Karry Zhuang 27.1 87 If your device's digital scroll wheel dial does not match these five fields, you can try the other field dial coordinate dot plots in 2.4.
Karry Zhuang 26.1 88
Karry Zhuang 45.3 89 (% aria-label="1713573839396-314.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713573839396-314.png||data-widget="image" height="198" width="649"]](% title="Click and drag to resize" %)​
Karry Zhuang 26.1 90
Karry Zhuang 56.3 91 The computer's drawing tool can be used to open the latest bmp image and get the coordinates of the digital wheel dial, as shown below. Based on the format of the digital wheel dial, we can obtain each coordinate point of the current use dial. The (x,y) coordinate on the image is located at the bottom left corner.
Karry Zhuang 26.1 92
Karry Zhuang 45.3 93 (% aria-label="1713574859715-722.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713574859715-722.png||data-widget="image" height="481" width="576"]](% title="Click and drag to resize" %)​
Karry Zhuang 26.1 94
Karry Zhuang 27.1 95 Click the "ROI setting" button in "HIMAX_AMR_PC_Tool" and three options will pop up
Karry Zhuang 29.1 96
Karry Zhuang 27.1 97 The "Long dial" option is the long hand dial.
Karry Zhuang 29.1 98
Karry Zhuang 27.1 99 The "Short dial" option is the short pointer and digital wheel dial.
Karry Zhuang 29.1 100
Karry Zhuang 27.1 101 The "Digit wheel" option is the digital wheel dial.
Karry Zhuang 29.1 102
Karry Zhuang 27.1 103 Now we are calibrating the digital wheel face of the water meter. Here we select "digit wheel".
Karry Zhuang 26.1 104
Karry Zhuang 45.3 105 (% aria-label="1713576691266-408.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713576691266-408.png||data-widget="image"]](% title="Click and drag to resize" %)​
Karry Zhuang 26.1 106
Karry Zhuang 29.1 107 1:Fill in the coordinates you just got; it's best to get a coordinate and fill in a coordinate.
Karry Zhuang 26.1 108
Karry Zhuang 45.2 109 2: Fill in the number of number wheel on their dial,fi;
Karry Zhuang 26.1 110
Karry Zhuang 27.1 111 3: Select the number of short Pointers (currently we don't use short Pointers, the "digit wheelu" option defaults to 0);
Karry Zhuang 26.1 112
Karry Zhuang 27.1 113 4: Preview whether the setting of their coordinates is accurate;
Karry Zhuang 26.1 114
Karry Zhuang 27.1 115 5: Click to write all configuration to AIS;
Karry Zhuang 26.1 116
Karry Zhuang 27.1 117 6: Click the exit configuration interface, at this time, there will be a readout. If the Reading of "reading" is consistent with the watch face, the calibration is successful. The AIS cannot move thereafter to avoid misreading.
Karry Zhuang 26.1 118
Karry Zhuang 45.3 119 (% aria-label="1713576930301-479.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713576930301-479.png||data-widget="image"]](% title="Click and drag to resize" %)​
Karry Zhuang 26.1 120
Karry Zhuang 27.1 121 The effect can be previewed by clicking the "Preview correction" button as shown below.
Karry Zhuang 26.1 122
Karry Zhuang 27.1 123 (% aria-label="1713577029535-253.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713577029535-253.png||data-widget="image" height="748" width="1069"]](% style="background:url(~"http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
Karry Zhuang 26.1 124
125
Karry Zhuang 27.1 126 After the calibration process is completed, it can be observed that the obtained reading aligns consistently with the numerical value displayed on the digital wheel dial.
Karry Zhuang 26.1 127
Karry Zhuang 45.2 128 (% aria-label="1713577072196-132.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713577072196-132.png||data-widget="image" height="751" width="1073"]]
Karry Zhuang 26.1 129
Karry Zhuang 45.2 130 (% title="Click and drag to resize" %)​
131
Karry Zhuang 58.4 132 == 2.2 Calibration Power Meter ==
Karry Zhuang 26.1 133
Karry Zhuang 30.1 134 === 2.2.1 Introduce ===
135
Karry Zhuang 39.2 136 This power meter is designed in accordance with the Chinese standard for Electricity metering equipment, GB/T 17215.321-2008. It features six dial numbers for measurement accuracy.
Karry Zhuang 30.1 137
Karry Zhuang 96.1 138 === 2.2.2 Fix Sensor to a Power Meter(% title="Click and drag to resize" %)​(%%) ===
Karry Zhuang 30.1 139
Karry Zhuang 93.2 140 You can utilize a couple of pea clips or other suitable fixtures to securely fasten the AIS sensor and ensure precise alignment of the camera with the digital watch wheel.
Karry Zhuang 30.1 141
Karry Zhuang 102.1 142 [[image:image-20240429091325-1.png||height="706" width="535"]]
Karry Zhuang 30.1 143
144 === 2.2.3 Calibration ===
145
Karry Zhuang 158.1 146 Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
Karry Zhuang 30.1 147
Karry Zhuang 175.1 148 For example, Select the corresponding serial port number, here 14.
Karry Zhuang 56.5 149
Karry Zhuang 30.1 150 (% class="box warningmessage" %)
151 (((
Karry Zhuang 158.1 152 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the [[visualcppredist_aio_x6_x64_v42.exe>>https://www.dropbox.com/scl/fi/mzqx6ld5a4zkcecntqjjg/VisualCppRedist_AIO_x86_x64_v42.rar?rlkey=9fuzodmed1fg9ulquh22h0dtr&st=ph6ozi4d&dl=0]] configuration environment. Otherwise, an error pop-up window occurs when running software.
Karry Zhuang 30.1 153 )))
154
Karry Zhuang 45.2 155 (% aria-label="1713519971789-213.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713519971789-213.png||data-widget="image"]](% title="Click and drag to resize" %)​
Karry Zhuang 30.1 156
157 Next, select a Baud rate of 921600 and click on "start". Then, click on "show full image" to display the camera screen.
158
Karry Zhuang 49.2 159 (% aria-label="image-20240419174908-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174908-5.png||data-widget="image" height="491" width="406"]][[image:image-20240420135207-3.png||height="485" width="706"]]
Karry Zhuang 39.2 160
Karry Zhuang 41.2 161 Click "enable Raw" and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
Karry Zhuang 39.2 162
Karry Zhuang 41.2 163 [[image:1713592384928-500.png||height="494" width="266"]][[image:image-20240420141955-4.png||height="492" width="782"]]
Karry Zhuang 39.2 164
Karry Zhuang 41.2 165 This power meter has only six fields, and the coordinates of the digital roulette wheel are shown in the figure.
Karry Zhuang 39.2 166
Karry Zhuang 41.2 167 If your device's digital scroll wheel dial does not match these six fields, you can try the other field dial coordinate dot plots in 2.4.
Karry Zhuang 39.2 168
Karry Zhuang 41.2 169 (% aria-label="image-20240420094632-13.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-13.png||data-widget="image" height="148" width="588"]]
Karry Zhuang 39.2 170
Karry Zhuang 56.3 171 The computer's drawing tool can be used to open the latest bmp image and get the coordinates of the digital wheel dial, as shown below. Based on the format of the digital wheel dial, we can obtain each coordinate point of the current use dial. The (x,y) coordinate on the image is located at the bottom left corner.
Karry Zhuang 41.2 172
Karry Zhuang 51.2 173 [[image:image-20240420153316-11.png||height="569" width="755"]]
Karry Zhuang 39.2 174
Karry Zhuang 41.3 175 (% id="cke_bm_67462S" style="display:none" %) (%%)Click the "ROI setting" button in "HIMAX_AMR_PC_Tool" and three options will pop up
176
177 The "Long dial" option is the long hand dial.
178
179 The "Short dial" option is the short pointer and digital wheel dial.
180
181 The "Digit wheel" option is the digital wheel dial.
182
183 Now we are calibrating the digital wheel face of the power meter. Here we select "digit wheel".
184
Karry Zhuang 45.3 185 (% aria-label="1713576691266-408.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713576691266-408.png||data-widget="image"]](% title="Click and drag to resize" %)​
Karry Zhuang 41.3 186
187 1: Fill in the coordinates you just got; it's best to get a coordinate and fill in a coordinate.
188
Karry Zhuang 45.2 189 2: Fill in the number of number wheel on their dial,six;
Karry Zhuang 41.3 190
191 3: Select the number of short Pointers (currently we don't use short Pointers, the "digit wheelu" option defaults to 0);
192
193 4: Preview whether the setting of their coordinates is accurate;
194
195 5: Click to write all configuration to AIS;
196
197 6: Click the exit configuration interface, at this time, there will be a readout. If the Reading of "reading" is consistent with the watch face, the calibration is successful. The AIS cannot move thereafter to avoid misreading.
198
Karry Zhuang 45.2 199 [[image:image-20240420143939-6.png||height="408" width="886"]](% title="Click and drag to resize" %)​
Karry Zhuang 41.3 200
201 The effect can be previewed by clicking the "Preview correction" button as shown below.
202
Karry Zhuang 45.2 203 [[image:image-20240420144154-7.png||height="534" width="880"]]
Karry Zhuang 41.3 204
Karry Zhuang 45.2 205 After the calibration process is completed, it can be observed that the obtained reading aligns consistently with the numerical value displayed on the digital wheel dial.
Karry Zhuang 41.3 206
Karry Zhuang 45.2 207 [[image:1713595371004-125.png]]
Karry Zhuang 41.3 208
209
Karry Zhuang 58.4 210 == 2.3 Calibration Gas Meter ==
Karry Zhuang 26.1 211
Karry Zhuang 47.2 212 === 2.3.1 Introduce ===
Karry Zhuang 45.4 213
Karry Zhuang 47.2 214 This gas meter uses G2.5 membrane gas meter. It features eight dial numbers for measurement accuracy.
Karry Zhuang 45.4 215
Karry Zhuang 47.2 216 === 2.3.2 Fix Sensor to a Gas Meter ===
Karry Zhuang 45.4 217
Karry Zhuang 96.1 218 You can utilize a couple of pea clips or other suitable fixtures to securely fasten the AIS sensor and ensure precise alignment of the camera with the digital watch wheel.
Karry Zhuang 45.4 219
Karry Zhuang 102.1 220 [[image:image-20240429092436-2.png||height="676" width="519"]]
Karry Zhuang 45.4 221
Karry Zhuang 99.1 222
Karry Zhuang 62.1 223 === 2.3.3 Calibration ===
Karry Zhuang 47.2 224
Karry Zhuang 158.1 225 Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
Karry Zhuang 47.2 226
Karry Zhuang 175.1 227 For example, Select the corresponding serial port number, here 14.
Karry Zhuang 56.5 228
Karry Zhuang 47.2 229 (% class="box warningmessage" %)
230 (((
Karry Zhuang 158.1 231 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the [[visualcppredist_aio_x6_x64_v42.exe>>https://www.dropbox.com/scl/fi/mzqx6ld5a4zkcecntqjjg/VisualCppRedist_AIO_x86_x64_v42.rar?rlkey=9fuzodmed1fg9ulquh22h0dtr&st=ph6ozi4d&dl=0]] configuration environment. Otherwise, an error pop-up window occurs when running software.
Karry Zhuang 47.2 232 )))
233
234 (% aria-label="1713519971789-213.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713519971789-213.png||data-widget="image"]](% title="Click and drag to resize" %)​
235
236 Next, select a Baud rate of 921600 and click on "start". Then, click on "show full image" to display the camera screen.
237
Karry Zhuang 49.2 238 (% aria-label="image-20240419174908-5.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240419174908-5.png||data-widget="image" height="491" width="406"]][[image:1713598021017-402.png]]
Karry Zhuang 47.2 239
Karry Zhuang 49.2 240 Click "enable Raw" and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
Karry Zhuang 47.2 241
Karry Zhuang 49.2 242 [[image:1713592384928-500.png||height="494" width="266"]][[image:1713598094208-496.png||height="494" width="790"]]
Karry Zhuang 47.2 243
Karry Zhuang 56.4 244 This gas meter has eight fields, and the coordinates of the digital roulette wheel are shown in the figure.
Karry Zhuang 47.2 245
Karry Zhuang 49.2 246 If your device's digital scroll wheel dial does not match these eight fields, you can try the other field dial coordinate dot plots in 2.4.
Karry Zhuang 47.2 247
Karry Zhuang 49.2 248 (% aria-label="image-20240420094632-15.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-15.png||data-widget="image" height="113" width="542"]]
Karry Zhuang 47.2 249
Karry Zhuang 56.3 250 (% id="cke_bm_196694S" style="display:none" %) (%%)The computer's drawing tool can be used to open the latest bmp image and get the coordinates of the digital wheel dial, as shown below. Based on the format of the digital wheel dial, we can obtain each coordinate point of the current use dial. The (x,y) coordinate on the image is located at the bottom left corner.
Karry Zhuang 47.2 251
Karry Zhuang 50.2 252 [[image:image-20240420153139-10.png||height="530" width="710"]]
Karry Zhuang 49.2 253
Karry Zhuang 50.2 254 (% id="cke_bm_67462S" style="display:none" %) (%%)Click the "ROI setting" button in "HIMAX_AMR_PC_Tool" and three options will pop up
Karry Zhuang 49.2 255
Karry Zhuang 50.2 256 The "Long dial" option is the long hand dial.
Karry Zhuang 49.2 257
Karry Zhuang 50.2 258 The "Short dial" option is the short pointer and digital wheel dial.
259
260 The "Digit wheel" option is the digital wheel dial.
261
Karry Zhuang 56.4 262 Now we are calibrating the digital wheel face of the gas meter. Here we select "digit wheel".
Karry Zhuang 50.2 263
264 (% aria-label="1713576691266-408.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713576691266-408.png||data-widget="image"]]
265
Karry Zhuang 54.2 266 1: Fill in the coordinates you just got; it's best to get a coordinate and fill in a coordinate.
Karry Zhuang 50.2 267
Karry Zhuang 54.2 268 2: Fill in the number of number wheel on their dial,eight;
Karry Zhuang 50.2 269
Karry Zhuang 54.2 270 3: Select the number of short Pointers (currently we don't use short Pointers, the "digit wheelu" option defaults to 0);
Karry Zhuang 50.2 271
Karry Zhuang 54.2 272 4: Preview whether the setting of their coordinates is accurate;
273
274 5: Click to write all configuration to AIS;
275
276 6: Click the exit configuration interface, at this time, there will be a readout. If the Reading of "reading" is consistent with the watch face, the calibration is successful. The AIS cannot move thereafter to avoid misreading.
277
278 [[image:image-20240420154023-12.png||height="436" width="942"]](% title="Click and drag to resize" %)​
279
280 The effect can be previewed by clicking the "Preview correction" button as shown below.
281
282 [[image:1713598855240-454.png]]
283
284 After the calibration process is completed, it can be observed that the obtained reading aligns consistently with the numerical value displayed on the digital wheel dial.
285
Karry Zhuang 104.1 286 [[image:1714358288601-933.png]]
Karry Zhuang 54.2 287
Karry Zhuang 27.1 288 == 2.4 Digital wheel dial take point coordinate diagram ==
Karry Zhuang 26.1 289
Karry Zhuang 27.1 290 4  numbers:
Karry Zhuang 26.1 291
Karry Zhuang 27.1 292 (% aria-label="image-20240420094632-11.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-11.png||data-widget="image" height="134" width="410"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
Karry Zhuang 26.1 293
Karry Zhuang 27.1 294 5 numbers:
Karry Zhuang 26.1 295
Karry Zhuang 27.1 296 (% aria-label="image-20240420094632-12.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-12.png||data-widget="image" height="130" width="427"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
Karry Zhuang 26.1 297
Karry Zhuang 27.1 298 6 numbers:
Karry Zhuang 26.1 299
Karry Zhuang 27.1 300 (% aria-label="image-20240420094632-13.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-13.png||data-widget="image" height="112" width="444"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
Karry Zhuang 26.1 301
Karry Zhuang 27.1 302 7 numbers:
Karry Zhuang 26.1 303
Karry Zhuang 27.1 304 (% aria-label="image-20240420094632-14.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-14.png||data-widget="image" height="111" width="454"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
Karry Zhuang 26.1 305
Karry Zhuang 27.1 306 8 numbers:
Karry Zhuang 26.1 307
Karry Zhuang 164.2 308 (% aria-label="image-20240420094632-15.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-15.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]]
Edwin Chen 82.1 309
Karry Zhuang 164.2 310 (% title="Click and drag to resize" %)​
Edwin Chen 82.1 311
Karry Zhuang 164.2 312 == 2.5 Pressure Pointer Meter Calibration ==
313
314 === 2.5.1 Introduce ===
315
316 The pressure pointer meter of the example is 1.6MPa range
317
318 === 2.5.2 Fix Sensor to a Power Meter​ ===
319
320 You can utilize a couple of pea clips or other suitable fixtures to securely fasten the AIS sensor and ensure precise alignment of the camera with the pressure pointer meter.
321
322 [[image:image-20240516163229-1.jpeg||height="595" width="446"]]
323
324 === 2.5.3 Calibration ===
325
326 Open the software  [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
327
Karry Zhuang 175.1 328 For example, Select the corresponding serial port number, here 14.
Karry Zhuang 164.2 329
330 (% class="box warningmessage" %)
331 (((
332 (% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the [[visualcppredist_aio_x6_x64_v42.exe>>https://www.dropbox.com/scl/fi/mzqx6ld5a4zkcecntqjjg/VisualCppRedist_AIO_x86_x64_v42.rar?rlkey=9fuzodmed1fg9ulquh22h0dtr&st=ph6ozi4d&dl=0]] configuration environment. Otherwise, an error pop-up window occurs when running software.
333 )))
334
335 [[image:image-20240516163338-2.png||height="455" width="733"]]
336
337
338 Next, select a Baud rate of 921600 and click on "start". Then, click on "show full image" to display the camera screen.
339
340 [[image:image-20240516163423-3.png]]
341
342
343 Click "enable Raw" and save the BMP image in the "Save" folder. This step is necessary to obtain the coordinate points of the watch face.
344
345 [[image:image-20240516163501-4.png||height="482" width="694"]]
346
347 [[image:image-20240516163528-5.png||height="336" width="696"]]
348
349
350 The computer's drawing tool can be used to open the latest bmp image and get the coordinates of the pressure pointer meter, as shown below.
351
352 The coordinates of the pressure pointer table are located as shown below.
353
354 1 is the start point, 2 is the center point, and 3 is the end point.
355
356 The (x,y) coordinate on the image is located at the bottom left corner.
357
358 [[image:image-20240516163622-6.png||height="648" width="666"]]
359
360
Karry Zhuang 166.2 361 Click on the ROI settingbutton in himax_amr_pc_tool. it will have three optionsThe long dial" option is a long dial dial.The "short dial" option is a short pointer and a number of wheel dial.The digit wheeler option is the digital wheel dial.Now the calibration is the pressure pointer table, which is long dialon."
Karry Zhuang 164.2 362
Karry Zhuang 166.2 363 [[image:image-20240516163910-7.png]]
Karry Zhuang 164.2 364
365
Karry Zhuang 166.2 366 Fill in the values of the coordinates you just got, and it's best to get one and write one
Karry Zhuang 164.2 367
Karry Zhuang 166.2 368 1 Coordinates of the starting point of the scale
369
370 2 Coordinates of the center point of the dial
371
372 3 Coordinates of the end of the scale
373
374 4 Starting scale value
375
376 5 End point scale value *100
377
Karry Zhuang 174.1 378 After filling in the data, click "send ROI" to save the Settings and click "Cancel" to exit.
Karry Zhuang 166.2 379
Karry Zhuang 174.1 380 [[image:image-20240516164128-13.png||height="410" width="889"]]
Karry Zhuang 166.2 381
382
Karry Zhuang 174.1 383 After the calibration process is completed, The AIS cannot move thereafter to avoid misreading.
Karry Zhuang 166.2 384
Karry Zhuang 174.1 385 it can be observed that the obtained reading aligns consistently with the numerical value displayed on the digital wheel dial.
Karry Zhuang 166.2 386
Karry Zhuang 174.1 387 [[image:image-20240516164153-14.png]]
Karry Zhuang 166.2 388
389
390
Edwin Chen 82.1 391 = (% title="Click and drag to resize" %)3. Get Sensor Data.(%%) =
392
393
Karry Zhuang 151.2 394 == (% title="Click and drag to resize" %)3.1 Get Image and show in PC(%%) ==
Edwin Chen 82.1 395
Karry Zhuang 150.1 396 To get the AIS current image on the PC, you can  connect AIS to your PC with TTL to send commands through the serial port to obtain relevant data packets.
Karry Zhuang 119.2 397
Karry Zhuang 151.2 398 === (% id="cke_bm_3839S" style="display:none" %) (%%)3.1.1 The image date are obtained by serial port ===
Karry Zhuang 119.2 399
Karry Zhuang 150.1 400 Select the corresponding baud rate and serial port number through the serial port tool, select HEX display and HEX send, and continuously receive data from the AIS Sensor
Karry Zhuang 119.3 401
Karry Zhuang 155.1 402 [[image:image-20240514161623-2.png||height="541" width="1439"]]
Karry Zhuang 119.4 403
Karry Zhuang 150.1 404 In the serial port to send data C0 5A 00 00 00 00 04, and then send C0 5A 00 00 00 00 09, AIS Sensor will send a real-time image of the data packet, and then stop sending. Start with FFD8 and put it in TXT file
Karry Zhuang 119.4 405
Karry Zhuang 155.1 406 [[image:image-20240514161658-3.png||height="544" width="1441"]]
Karry Zhuang 119.4 407
408
Karry Zhuang 151.2 409 === 3.1.2 Combined image ===
Karry Zhuang 119.4 410
Karry Zhuang 130.5 411 Once all the data has been uploaded to the TTN platform, the subsequent step involves concatenating each packet in sequential order and saving it into a new TXT file. It is important to note that the first 8 bytes of each packet should be removed before concatenation.
Karry Zhuang 130.2 412
Karry Zhuang 130.5 413 When you combine all the packets, you need to convert the data inside to binary. Here the conversion is demonstrated using the [[WinHex>>http://www.x-ways.net/winhex/index-m.html]] software.
Karry Zhuang 130.2 414
Karry Zhuang 136.2 415 Open WinHex to open the combined image data file.
Karry Zhuang 130.3 416
Karry Zhuang 136.2 417 [[image:1714467040612-103.png||height="134" width="649"]]
Karry Zhuang 130.4 418
Karry Zhuang 136.2 419 Click on the edit option to choose and convert.
Karry Zhuang 130.4 420
Karry Zhuang 136.2 421 [[image:1714467065723-178.png||height="349" width="762"]]
422
423 Choose the Hex ASCII->Binary option and then click OK.
424
425 [[image:1714467089355-837.png||height="366" width="336"]]
426
427 After the conversion is finished, click on "File" and choose "Save As".
428
429 [[image:1714467112365-676.png]]
430
431 Save as a.jpg file and click OK to generate a JPG file.
432
433 [[image:1714467126476-110.png]]
434
435 Open the saved JPG file to display the image transmitted by the AIS Sensor through the serial port.
436
437 [[image:1714467134950-189.png]]
438
Karry Zhuang 157.1 439 === ===