Changes for page AI Image Sensor Calibration
Last modified by Karry Zhuang on 2025/07/03 11:59
From version 92.1
edited by Karry Zhuang
on 2024/04/28 16:56
on 2024/04/28 16:56
Change comment:
Uploaded new attachment "image-20240428165645-8.jpeg", version {1}
To version 96.1
edited by Karry Zhuang
on 2024/04/28 18:00
on 2024/04/28 18:00
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -35,7 +35,7 @@ 35 35 36 36 The procedure is as follows: 37 37 38 -~1. Secure the AIS sensor onto the small board and adjust its position according to your requirements. You may use two additional screws for fixation or utilize 3M double-sided adhesive for attachment. 38 +~1. Secure back of the AIS sensor onto the small board and adjust its position according to your requirements. You may use two additional screws for fixation or utilize 3M double-sided adhesive for attachment. 39 39 40 40 [[image:image-20240428165320-4.gif]] 41 41 ... ... @@ -47,22 +47,16 @@ 47 47 48 48 [[image:image-20240428165412-6.gif]]. 49 49 50 +The AI Sensors and AUC USB TTL Adapter for AIS Sensors are connected and then connected to the PC. 50 50 51 -(% class="wikigeneratedid" %) 52 -=== === 52 +[[image:image-20240428165634-7.gif]][[image:image-20240428165645-8.jpeg||height="332" width="443"]] 53 53 54 -(% id="cke_bm_19954S" style="display:none" %) (%%)The AI Sensors and AUC USB TTL Adapter for AIS Sensors are connected and then connected to the PC. 55 55 56 56 57 -The AI Sensors are fixed in the device, and then the water meter is embedded and the Angle is adjusted. 58 58 59 - 60 -[[image:image-20240428155835-2.png||height="493" width="371"]] 61 - 62 - 63 63 === 2.1.3 Calibration === 64 64 65 - Revised sentence:Launch [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.59 +Launch [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe. 66 66 67 67 Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14. 68 68 ... ... @@ -136,19 +136,12 @@ 136 136 137 137 This power meter is designed in accordance with the Chinese standard for Electricity metering equipment, GB/T 17215.321-2008. It features six dial numbers for measurement accuracy. 138 138 139 -=== 2.2.2 Fix Sensor to a Power Meter === 133 +=== 2.2.2 Fix Sensor to a Power Meter(% title="Click and drag to resize" %)(%%) === 140 140 141 -Do the following with EVB_Board 142 -Debug Board SW12=[off on] : FT4222H SPI Slave mode 143 -AIoT Board SW123456=[off off off off off off] 135 +You can utilize a couple of pea clips or other suitable fixtures to securely fasten the AIS sensor and ensure precise alignment of the camera with the digital watch wheel. 144 144 145 - (% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220, 0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true"height="15"role="presentation" title="Click and drag to move"width="15"]](% title="Click and drag to resize" %)(%%) (% title="Click and drag to resize" %)137 +[[image:image-20240428175834-9.jpeg||height="745" width="559"]] 146 146 147 -Use a hot glue gun and several sticks to attach a triangle for stabilizing the AIS. Adjust the height of the sticks so that the AIS can clearly view the numbers on the power meter. 148 - 149 -[[image:image-20240422092350-2.png]](% title="Click and drag to resize" %) 150 - 151 - 152 152 === 2.2.3 Calibration === 153 153 154 154 Perform a power reset on the EVB board, making sure to close the ota.exe program before opening HMX_FT4222H_GUI.exe. ... ... @@ -223,17 +223,10 @@ 223 223 224 224 === 2.3.2 Fix Sensor to a Gas Meter === 225 225 226 -Do the following with EVB_Board 227 -Debug Board SW12=[off on] : FT4222H SPI Slave mode 228 -AIoT Board SW123456=[off off off off off off] 213 +You can utilize a couple of pea clips or other suitable fixtures to securely fasten the AIS sensor and ensure precise alignment of the camera with the digital watch wheel. 229 229 230 - (% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220, 0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true"height="15"role="presentation" title="Click and drag to move"width="15"]](% title="Click and drag to resize" %)(%%) (% title="Click and drag to resize" %)215 +[[image:image-20240428175925-10.jpeg||height="529" width="397"]] 231 231 232 -Use a hot glue gun and several sticks to attach for stabilizing the AIS. Adjust the height of the sticks so that the AIS can clearly view the numbers on the gas meter. 233 - 234 -(% title="Click and drag to resize" %)[[image:image-20240422092731-2.png||height="693" width="518"]] 235 - 236 - 237 237 === 2.3.3 Calibration === 238 238 239 239 Perform a power reset on the EVB board, making sure to close the ota.exe program before opening HMX_FT4222H_GUI.exe.
- image-20240428175834-9.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +2.7 MB - Content
- image-20240428175925-10.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +2.3 MB - Content