Last modified by Karry Zhuang on 2025/07/03 11:59

From version 90.1
edited by Karry Zhuang
on 2024/04/28 16:54
Change comment: Uploaded new attachment "image-20240428165412-6.gif", version {1}
To version 97.1
edited by Karry Zhuang
on 2024/04/28 18:01
Change comment: Uploaded new attachment "image-20240428180114-11.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -18,12 +18,7 @@
18 18  
19 19  = 2. Calibrate Digits Readings =
20 20  
21 -The AI Sensors and AUC USB TTL Adapter for AIS Sensors are connected and then connected to the PC.
22 22  
23 - [[image:image-20240428155254-1.png||height="519" width="439"]]
24 -
25 -[[image:image-20240424163158-2.gif]][[image:image-20240424163213-3.jpeg||height="360" width="480"]]
26 -
27 27  == 2.1 Calibrate a Water Meter ==
28 28  
29 29  === 2.1.1 Introduce ===
... ... @@ -30,18 +30,38 @@
30 30  
31 31  This water meter is designed in accordance with the Chinese standard for drinking cold water meters and hot water meters, GB/T 778.1-2007. It features five dial numbers for measurement accuracy.
32 32  
33 -=== 2.1.2 Fix Sensor to a Water Meter(% title="Click and drag to resize" %)​(%%) ===
28 +=== 2.1.2 Fix Sensor to a Water Meter ===
34 34  
35 -The AI Sensors are fixed in the device, and then the water meter is embedded and the Angle is adjusted.
30 +The assembly necessitates the use of two screws, two spacers, and this specific device. Additionally, there are AIS Sensors available along with TTL adapters for AIS Sensors.
36 36  
37 37  The fixture below is just a demo, user might adjust it with their water meter. Here is the STEP file for the fixture as below: [[Water Meter Fixture Demo>>https://www.dropbox.com/scl/fo/p1ykgysrv8p454swsh4zj/AHCYr5pcOM0WNad4fT1sf_I?rlkey=7x964q1tuvh0ezbhgxb9b2zqg&st=wxxq87t3&dl=0]].
38 38  
39 -[[image:image-20240428155835-2.png||height="493" width="371"]]
34 +[[image:image-20240428163842-3.png||height="425" width="609"]] [[image:image-20240428155254-1.png||height="424" width="358"]]
40 40  
36 +The procedure is as follows:
41 41  
38 +~1. Secure back of the AIS sensor  onto the small board and adjust its position according to your requirements. You may use two additional screws for fixation or utilize 3M double-sided adhesive for attachment.
39 +
40 +[[image:image-20240428165320-4.gif]]
41 +
42 +2. Proceed by fastening the device using the previously prepared screws and gaskets.
43 +
44 +[[image:image-20240428165354-5.gif]]
45 +
46 +3. Finally, nestle the device onto your water meter, ensuring that it can be adjusted to meet your specific needs while guaranteeing that the camera is directed towards the digital wheel face.
47 +
48 +[[image:image-20240428165412-6.gif]].
49 +
50 +The AI Sensors and AUC USB TTL Adapter for AIS Sensors are connected and then connected to the PC.
51 +
52 +[[image:image-20240428165634-7.gif]][[image:image-20240428165645-8.jpeg||height="332" width="443"]]
53 +
54 +
55 +
56 +
42 42  === 2.1.3 Calibration ===
43 43  
44 -Revised sentence: Launch [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
59 +Launch [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
45 45  
46 46  Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14.
47 47  
... ... @@ -115,19 +115,12 @@
115 115  
116 116  This power meter is designed in accordance with the Chinese standard for Electricity metering equipment, GB/T 17215.321-2008. It features six dial numbers for measurement accuracy.
117 117  
118 -=== 2.2.2 Fix Sensor to a Power Meter ===
133 +=== 2.2.2 Fix Sensor to a Power Meter(% title="Click and drag to resize" %)​(%%) ===
119 119  
120 -Do the following with EVB_Board
121 -Debug Board SW12=[off on] : FT4222H SPI Slave mode
122 -AIoT Board SW123456=[off off off off off off]
135 +You can utilize a couple of pea clips or other suitable fixtures to securely fasten the AIS sensor and ensure precise alignment of the camera with the digital watch wheel.
123 123  
124 -(% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220, 220, 220, 0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​(%%) (% title="Click and drag to resize" %)​
137 +[[image:image-20240428175834-9.jpeg||height="745" width="559"]]
125 125  
126 -Use a hot glue gun and several sticks to attach a triangle for stabilizing the AIS. Adjust the height of the sticks so that the AIS can clearly view the numbers on the power meter.
127 -
128 -[[image:image-20240422092350-2.png]](% title="Click and drag to resize" %)​
129 -
130 -
131 131  === 2.2.3 Calibration ===
132 132  
133 133  Perform a power reset on the EVB board, making sure to close the ota.exe program before opening HMX_FT4222H_GUI.exe.
... ... @@ -202,17 +202,10 @@
202 202  
203 203  === 2.3.2 Fix Sensor to a Gas Meter ===
204 204  
205 -Do the following with EVB_Board
206 -Debug Board SW12=[off on] : FT4222H SPI Slave mode
207 -AIoT Board SW123456=[off off off off off off]
213 +You can utilize a couple of pea clips or other suitable fixtures to securely fasten the AIS sensor and ensure precise alignment of the camera with the digital watch wheel.
208 208  
209 -(% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220, 220, 220, 0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​(%%) (% title="Click and drag to resize" %)​
215 +[[image:image-20240428175925-10.jpeg||height="529" width="397"]]
210 210  
211 -Use a hot glue gun and several sticks to attach  for stabilizing the AIS. Adjust the height of the sticks so that the AIS can clearly view the numbers on the gas meter.
212 -
213 -(% title="Click and drag to resize" %)​[[image:image-20240422092731-2.png||height="693" width="518"]]
214 -
215 -
216 216  === 2.3.3 Calibration ===
217 217  
218 218  Perform a power reset on the EVB board, making sure to close the ota.exe program before opening HMX_FT4222H_GUI.exe.
image-20240428165634-7.gif
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.karry
Size
... ... @@ -1,0 +1,1 @@
1 +3.2 MB
Content
image-20240428165645-8.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.karry
Size
... ... @@ -1,0 +1,1 @@
1 +2.9 MB
Content
image-20240428175834-9.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.karry
Size
... ... @@ -1,0 +1,1 @@
1 +2.7 MB
Content
image-20240428175925-10.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.karry
Size
... ... @@ -1,0 +1,1 @@
1 +2.3 MB
Content
image-20240428180114-11.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.karry
Size
... ... @@ -1,0 +1,1 @@
1 +3.0 MB
Content