Changes for page AI Image Sensor Calibration
Last modified by Karry Zhuang on 2025/07/03 11:59
From version 80.1
edited by Karry Zhuang
on 2024/04/26 15:10
on 2024/04/26 15:10
Change comment:
There is no comment for this version
To version 85.1
edited by Karry Zhuang
on 2024/04/28 15:58
on 2024/04/28 15:58
Change comment:
Uploaded new attachment "image-20240428155835-2.png", version {1}
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -18,9 +18,9 @@ 18 18 19 19 = 2. Calibrate Digits Readings = 20 20 21 -The AI Sensors and UART are connected and then connected to the PC.21 +The AI Sensors and AUC USB TTL Adapter for AIS Sensors are connected and then connected to the PC. 22 22 23 - [[image:image-2024042 4163117-1.png||height="520" width="450"]]23 + [[image:image-20240428155254-1.png||height="519" width="439"]] 24 24 25 25 [[image:image-20240424163158-2.gif]][[image:image-20240424163213-3.jpeg||height="360" width="480"]] 26 26 ... ... @@ -34,12 +34,14 @@ 34 34 35 35 The AI Sensors are fixed in the device, and then the water meter is embedded and the Angle is adjusted. 36 36 37 +The fixture below is just a demo, user might adjust it with their water meter. Here is the STEP file for the fixture as below: [[Water Meter Fixture Demo>>https://www.dropbox.com/scl/fo/p1ykgysrv8p454swsh4zj/AHCYr5pcOM0WNad4fT1sf_I?rlkey=7x964q1tuvh0ezbhgxb9b2zqg&st=wxxq87t3&dl=0]]. 38 + 37 37 [[image:image-20240424163340-4.jpeg||height="709" width="532"]] 38 38 39 39 40 40 === 2.1.3 Calibration === 41 41 42 - Performa powereton theEVB board,makingsureto closethe ota.exeprogrambefore opening HMX_FT4222H_GUI.exe.44 +Revised sentence: Launch [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe. 43 43 44 44 Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14. 45 45 ... ... @@ -296,3 +296,13 @@ 296 296 8 numbers: 297 297 298 298 (% aria-label="image-20240420094632-15.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-15.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 301 + 302 + 303 += (% title="Click and drag to resize" %)3. Get Sensor Data.(%%) = 304 + 305 +== (% title="Click and drag to resize" %)3.1 Get Digital Reading After Calibration(%%) == 306 + 307 + 308 +== (% title="Click and drag to resize" %)3.2 Get Image and show in PC(%%) == 309 + 310 +
- image-20240428155254-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +3.1 MB - Content
- image-20240428155835-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +2.6 MB - Content