Summary

Details

Page properties
Content
... ... @@ -18,9 +18,9 @@
18 18  
19 19  = 2. Calibrate Digits Readings =
20 20  
21 -The AI Sensors and UART are connected and then connected to the PC.
21 +The AI Sensors and AUC USB TTL Adapter for AIS Sensors are connected and then connected to the PC.
22 22  
23 - [[image:image-20240424163117-1.png||height="520" width="450"]]
23 + [[image:image-20240428155254-1.png||height="519" width="439"]]
24 24  
25 25  [[image:image-20240424163158-2.gif]][[image:image-20240424163213-3.jpeg||height="360" width="480"]]
26 26  
... ... @@ -34,18 +34,20 @@
34 34  
35 35  The AI Sensors are fixed in the device, and then the water meter is embedded and the Angle is adjusted.
36 36  
37 +The fixture below is just a demo, user might adjust it with their water meter. Here is the STEP file for the fixture as below: [[Water Meter Fixture Demo>>https://www.dropbox.com/scl/fo/p1ykgysrv8p454swsh4zj/AHCYr5pcOM0WNad4fT1sf_I?rlkey=7x964q1tuvh0ezbhgxb9b2zqg&st=wxxq87t3&dl=0]].
38 +
37 37  [[image:image-20240424163340-4.jpeg||height="709" width="532"]]
38 38  
39 39  
40 40  === 2.1.3 Calibration ===
41 41  
42 -Perform a power reset on the EVB board, making sure to close the ota.exe program before opening HMX_FT4222H_GUI.exe.
44 +Revised sentence: Launch [[HMX_FT4222H_GUI.exe>>https://www.dropbox.com/scl/fi/yktibns4o33oh0lqitqjl/HIMAX_AMR_PC_Tool.7z?rlkey=94d637ntx152idhw8vij39icv&st=4lsq8xf9&dl=0]]. Please ensure that the firmware upgrade software ota.exe is closed before opening HMX_FT4222H_GUI.exe.
43 43  
44 44  Choose the largest number of serial port, for example, here shows 13 and 14, then choose 14.
45 45  
46 46  (% class="box warningmessage" %)
47 47  (((
48 -(% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the visualcppredist_aio_x6_x64_v42.exe configuration environment. Otherwise, an error pop-up window occurs when running software.
50 +(% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the [[visualcppredist_aio_x6_x64_v42.exe>>https://www.dropbox.com/scl/fi/mzqx6ld5a4zkcecntqjjg/VisualCppRedist_AIO_x86_x64_v42.rar?rlkey=9fuzodmed1fg9ulquh22h0dtr&st=ph6ozi4d&dl=0]] configuration environment. Otherwise, an error pop-up window occurs when running software.
49 49  )))
50 50  
51 51  (% aria-label="1713519971789-213.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1713519971789-213.png||data-widget="image"]](% title="Click and drag to resize" %)​
... ... @@ -296,3 +296,13 @@
296 296  8 numbers:
297 297  
298 298  (% aria-label="image-20240420094632-15.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:image-20240420094632-15.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
301 +
302 +
303 += (% title="Click and drag to resize" %)3. Get Sensor Data.(%%) =
304 +
305 +== (% title="Click and drag to resize" %)3.1 Get Digital Reading After Calibration(%%) ==
306 +
307 +
308 +== (% title="Click and drag to resize" %)3.2 Get Image and show in PC(%%) ==
309 +
310 +
image-20240428155254-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.karry
Size
... ... @@ -1,0 +1,1 @@
1 +3.1 MB
Content