... ... @@ -30,19 +30,13 @@
30 30  
31 31  This water meter is designed in accordance with the Chinese standard for drinking cold water meters and hot water meters, GB/T 778.1-2007. It features five dial numbers for measurement accuracy.
32 32  
33 -=== 2.1.2 Fix Sensor to a Water Meter ===
33 +=== 2.1.2 Fix Sensor to a Water Meter(% title="Click and drag to resize" %)​(%%) ===
34 34  
35 -Do the following with EVB_Board
36 -Debug Board SW12=[off on] : FT4222H SPI Slave mode
37 -AIoT Board SW123456=[off off off off off off]
35 +The AI Sensors are fixed in the device, and then the water meter is embedded and the Angle is adjusted.
38 38  
39 -(% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​(%%) (% title="Click and drag to resize" %)​
37 +[[image:image-20240424163340-4.jpeg||height="709" width="532"]]
40 40  
41 -Use a hot glue gun and several sticks to attach a triangle for stabilizing the AIS. Adjust the height of the sticks so that the AIS can clearly view the numbers on the water meter.
42 42  
43 -[[image:image-20240422092251-1.png]]
44 -
45 -
46 46  === 2.1.3 Calibration ===
47 47  
48 48  Perform a power reset on the EVB board, making sure to close the ota.exe program before opening HMX_FT4222H_GUI.exe.
... ... @@ -51,7 +51,7 @@
51 51  
52 52  (% class="box warningmessage" %)
53 53  (((
54 -(% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the visualcppredist_aio_x6_x64_v42.exe configuration environment. Otherwise, an error pop-up window occurs when running software.
48 +(% class="mark" %)Note: before you start the software (%%)HMX_FT4222H_GUI.exe(% class="mark" %). you must pre-install the [[visualcppredist_aio_x6_x64_v42.exe>>https://www.dropbox.com/scl/fi/mzqx6ld5a4zkcecntqjjg/VisualCppRedist_AIO_x86_x64_v42.rar?rlkey=9fuzodmed1fg9ulquh22h0dtr&st=ph6ozi4d&dl=0]] configuration environment. Otherwise, an error pop-up window occurs when running software.
55 55  )))
56 56  